Whirlpool 19760268A user manual

User manual for the device Whirlpool 19760268A

Device: Whirlpool 19760268A
Category: Ventilation Hood
Manufacturer: Whirlpool
Size: 0.72 MB
Added : 7/13/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Whirlpool 19760268A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Whirlpool 19760268A.

For your convenience

If looking through the Whirlpool 19760268A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Whirlpool 19760268A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Whirlpool 19760268A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Whirlpool 19760268A User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Whirlpool 19760268A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Whirlpool 19760268A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

36" (91.4 cm) WALL-MOUNT CANOPY RANGE HOOD
Installation Instructions and Use and Care Guide
HOTTE D'ASPIRATION POUR MONTAGE MURAL
36" (91,4 cm)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
IMPORTANT:
I

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE . . . . . . . . . . . . . .14 INSTALLATION REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . .4 EXIGENCES D'INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . .16 Outillage et pièces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Tools and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON w

Summary of the content on the page No. 4

INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the safety instructions provided with any tools Canopy hood location should be away from strong draft areas, listed here. such as windows, doors and strong heating vents. Tools needed: Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. ■ level Ground

Summary of the content on the page No. 5

Installation dimensions Venting methods 12" This canopy hood is factory set for venting through the roof or (30.5 cm) wall. 2" (50.1 mm) min. An 8" (20.3 cm) round vent system is needed for installation (not 10-1/2" (26.7 cm) included). The hood exhaust opening is 8" (20.3 cm) round. Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed. Rear discharge A 90° elbow may be installed immediately above the hood. 12" vent and power (30.5 cm) For n

Summary of the content on the page No. 6

■ A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also Electrical Requirements recommended. It is recommended that a separate circuit serving only this hood be provided. WARNING ■ Do not ground to a gas pipe. ■ Check with a qualified electrician if you are not sure range hood is properly grounded. ■ Do not have a fuse in the neutral or ground circuit. ■ The range hood must be connected with copper wire only. ■ The range hood shoul

Summary of the content on the page No. 7

6. Place the lower support bracket on the template aligning it with the traced rectangle. Mark centers of 3 fastener locations Install Hood through the template to the wall. IMPORTANT: All screws must be installed into wood. WARNING Remove the template. Excessive Weight Hazard 7. Drill ⁷⁄₆₄" (2.75 mm) pilot holes at two upper locations where screws are being installed into wood. Use two or more people to move and install range hood. 8. Determine and make all necessary cuts in the wall for the ve

Summary of the content on the page No. 8

Non-vented (recirculating) installation Make Electrical Connection 1. Assemble the 3 parts of the deflector with 2 screws provided. The assembled deflector should be sized to fit the width of WARNING the vent cover bracket installed earlier. A Electrical Shock Hazard B Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. A. Vent cover bracket width B. Deflector 1. Disconnect power. 2. Connect the deflector to

Summary of the content on the page No. 9

9. Secure upper vent cover to vent cover bracket with 2 screws, one on either side. WARNING A B Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. C Failure to do so can result in death or electrical shock. 8. Use twist-on connectors and connect green or bare wire with yellow-green wire. 9. Replace terminal box cover. 10. Check all light bulbs to make sure they are secure in their sockets. 11. Reconnect power. A. Vent cover b

Summary of the content on the page No. 10

To replace the metal grease filters: 4. Insert back edge of filter into rear track of the filter opening. RANGE HOOD USE 5. Push handle toward the rear and push filter up. 6. Pull filter toward the front and insert into front track. Check Operation Charcoal Filters - For non-vented (recirculating) installations The charcoal filters capture unpleasant cooking odors. They can The canopy hood is designed to remove smoke, cooking vapors be cleaned and reactivated. With normal use the filter should b

Summary of the content on the page No. 11

Replacing a halogen lamp 3. Remove the lamp and replace with a 12-volt, 20W maximum, halogen lamp made for a G-4 base. Turn off the range hood and allow the halogen lamps to cool. 4. Replace the light cover. Replace bulb using a tissue to handle bulb, or wearing cotton gloves. Do not touch bulb with bare fingers. 5. Reconnect power. If new lights do not operate, make sure the lamps are inserted correctly before calling service. 1. Disconnect power. Accessories 2. Use a flat bladed screwdriver an

Summary of the content on the page No. 12

RANGE HOOD WARRANTY For one year from the date of purchase, when this appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation will pay for labor and any parts of your range hood, except light bulbs and filters, which are defective in materials or workmanship. Whirlpool Corporation will not pay for: 1. Service calls to correct the installation of your appliance, to instruct you how to use your appliance, to replace house fuse

Summary of the content on the page No. 13

7654 3 2 1 WIRING DIAGRAM BE06CA L N YELLOW Y/G YELLOW BE07AA YELLOW WHITE BLACK Y/G Y/G Y/G Y/G 6 WHITE WHITE WHITE 5 M RED RED RED 4 GREY GREY GREY 3 BLACK BLACK 2 BLUE BLUE BLUE 1 YELLOW YELLOW BROWN BROWN 13 BLACK WHITE 6 5 4 YELLOW 3 120V TRANSFORMER YELLOW YELLOW 2 12V YELLOW YELLOW 1

Summary of the content on the page No. 14

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte

Summary of the content on the page No. 15

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 16

EXIGENCES D'INSTALLATION Outillage et pièces Exigences d'emplacement Rassembler les outils et pièces nécessaires avant de commencer IMPORTANT : Observer les dispositions de tous les codes et l'installation. Lire et suivre les instructions fournies avec les outils règlements en vigueur. indiqués ici. Installer la hotte d'extraction à distance de toute zone exposée à des courants d'air telle que fenêtres, portes et bouches de Outillage nécessaire : chauffage. ■ niveau Respecter les dimensions ind

Summary of the content on the page No. 17

Air d'appoint Le code du bâtiment local peut exiger l'utilisation d'un système Espacements d'installation d'introduction d'air d'appoint dans le cas où la capacité d'extraction (pieds cubes d'air par minute) de la hotte est 12" (30,5 cm) supérieure à une valeur spécifiée. La valeur spécifiée (débit d'air, 2" (50,1 cm) en pieds cubes par minute) est variable d'une juridiction à une min. autre. Pour déterminer les exigences spécifiques, consulter un 10¹⁄₂" (26,7 cm) professionnel local des insta

Summary of the content on the page No. 18

Calcul de la longueur effective du circuit Spécifications électriques d'évacuation Pour calculer la longueur effective du circuit d'évacuation AVERTISSEMENT nécessaire, ajouter les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. Composant du circuit Conduit rond dia. 8" (20,3 cm) Coude à 45° 2,5 pi (0,8 m) Risque de choc électrique Coude à 90° 5,0 pi Déconnecter la source de courant électrique avant (1,5 m) l'entretien. Replacer pièces et panneaux avant d

Summary of the content on the page No. 19

INSTRUCTIONS D'INSTALLATION 5. Fixer le gabarit avec du ruban adhésif - aligner l'axe central du gabarit et le bas du gabarit avec les lignes correspondantes Préparation de l'emplacement tracées sur le mur (bas de la hotte et axe central). ■ On ne doit couper un poteau de colombage ou une solive que si c'est absolument nécessaire. S'il est nécessaire de couper un poteau ou une solive, on devra construire une structure de support appropriée. A ■ Avant d'exécuter les découpages, vérifier la dispo

Summary of the content on the page No. 20

2. Établir l'aplomb du carter du ventilateur avec les vis de Assemblage et installation de la bride du cache- réglage de l'aplomb associées aux crochets de montage - pour le contrôle, placer un niveau en travers du bas du carter conduit de ventilateur. 1. Avec 4 vis fournies, assembler les 3 sections de la bride du 3. Retirer le filtre; immobiliser le carter du ventilateur avec une cache-conduit. La taille de la bride assemblée doit vis placée dans le trou du bas, à l'arrière du ventilateur. co


Alternative user manuals
# User manual Category Download
1 Whirlpool 30 User manual Ventilation Hood 26
2 Whirlpool 35-718 User manual Ventilation Hood 7
3 Whirlpool 29-718 User manual Ventilation Hood 0
4 Whirlpool 4.32E+13 User manual Ventilation Hood 2
5 Whirlpool 24" (58 CM) User manual Ventilation Hood 3
6 Whirlpool 36" User manual Ventilation Hood 1
7 Whirlpool 9763375 User manual Ventilation Hood 1
8 Whirlpool 99044504A User manual Ventilation Hood 0
9 Whirlpool 48" User manual Ventilation Hood 2
10 Whirlpool 99044505A User manual Ventilation Hood 0
11 Whirlpool 761883306 User manual Ventilation Hood 0
12 Whirlpool 9760266 User manual Ventilation Hood 0
13 Whirlpool GZ5730 User manual Ventilation Hood 0
14 Whirlpool GZ5730XRB1 User manual Ventilation Hood 0
15 Whirlpool GZ5730XR User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0