D896 Automatic Vent Damper
PRODUCT DATA
FEATURES
• 4-wire plug receptacle.
• Includes wiring harness on select models to fit plug
receptacle onto S86/S8600/S8610/S8620 /L7148/L8148
or Penn Baso G60 or G66.
• For use only on atmospheric type gas-fired furnaces
and boilers equipped with draft hoods.
• Applicable to direct spark ignition (DSI), intermittent
pilot (IP), hot surface ignition (HSI), and standing pilot
systems.
• Ambient temperature range 32°F (0°C) to 150°F (65°C).
• Requires dual aut
Summary of the content on the page No. 2
D896 AUTOMATIC VENT DAMPER Application: SPECIFICATIONS For use only on Underwriters Laboratories Inc. listed and American Gas Association design certified atmospheric type, IMPORTANT gas-fired furnaces and boilers equipped with a draft hood that The specifications given in this publication do not has an outlet area no larger than the damper inlet area. Do include normal manufacturing tolerances. Therefore, not use with oil-fired furnace or boiler, power burner, or direct this unit might not exac
Summary of the content on the page No. 3
D896 AUTOMATIC VENT DAMPER NOTE: A minimum of a 30 VA transformer must be used Approvals: when D896 is installed with S86/S8600/S8610/ American Gas Association Certified: S8620. Certificate No. U-66-2A1. Canadian Gas Association Design Certified: Electrical Connections: 1029AVD-9081. Four-wire plug receptacle. Replacement Parts: Thermostat Anticipator Setting: Damper Actuator is field replaceable without removing the 0.13A. damper assembly from the stack. 197516A Wiring Harness is a 4-wire cable
Summary of the content on the page No. 4
D896 AUTOMATIC VENT DAMPER IMPORTANT Location 1. The atmospheric draft hood outlet area must be The D896 must be installed after the furnace or boiler draft smaller or equal to the inlet area of the damper hood. See Fig. 2. Make sure the D896 Motor Actuator is assembly. readily visible and accessible. The damper must be located 2. If a second gas valve needs to be installed, refer where air can freely circulate around it. to the gas valve manufacturer instructions for the procedure. WARNING: DO
Summary of the content on the page No. 5
D896 AUTOMATIC VENT DAMPER HORIZONTAL VENT INSTALLATION D896 NO YES YES NO FLOW TO CHIMNEY FROM FURNACE OR BOILER INSTALL VENT DAMPER ONLY WITH ACTUATOR TO SIDES OF VENT. DO NOT MOUNT VENT DAMPER WITH ACTUATOR ABOVE OR BELOW THE VENT. VERTICAL VENT INSTALLATION TO CHIMNEY MOTOR ACTUATOR INSTALL VENT DAMPER WITH FLOW D896 ACTUATOR IN ANY POSITION. DAMPER DAMPER BLADE PLUG BLADE FROM FURNACE OR BOILER M11371 FOR DSI AND IP INSTALLATIONS ONLY – PLACE PLUG ON HOLE: HOLD DAMPER
Summary of the content on the page No. 6
D896 AUTOMATIC VENT DAMPER D896 Replacing D80B, D892 or Competitive Control with D896 SERVICE SWITCH IGNITION GAS NORM WARNING PWR LED SERV Bodily harm and/or death possible. Prevent CALL FOR unsupervised gas flow. HEAT LED Improper wiring (device malfunction) of the D80B, D892, D896 or competitive devices can cause unsupervised gas flow. HARNESS CABLE 1 CONNECTOR A wiring harness is included with most D896 models. Use the harness to wire the D896 according to the furnace or boiler manufacturer
Summary of the content on the page No. 7
D896 AUTOMATIC VENT DAMPER S8600F, H, M; S8610F,H 1 2 VENT GND 24V DAMPER MV MV/PV PV (BURNER) GND 24V TH-W PLUG SENSE SPARK WIRING 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS HARNESS AND OVERLOAD PROTECTION AS REQUIRED. D896 2 REMOVE PLUG ONLY IF USING VENT DAMPER. FUSE VENT BLOWS ON STARTUP WHEN PLUG IS REMOVED; DAMPER THEN MODULE OPERATES ONLY WHEN VENT M11375 DAMPER IS CONNECTED. Fig. 7. Wiring diagram for D896 connection to S8600/S8610 using wiring harness with two Molex plugs. 1. Wh
Summary of the content on the page No. 8
D896 AUTOMATIC VENT DAMPER 6. Cycle the heating system at least three times using the thermostat or controller to assure the system is operating safely. Cooling CAUTION Damage to air conditioner condenser possible. Do not operate cooling if outdoor temperature is below 50°F (10°C). 1. Set the thermostat or controller to COOL. Move the setpoint to 10°F (6°C) below the room temperature. 2. Make sure the cooling system operates. 3. Check that the D896 is in the closed position. See Fig. 11. 4. Retu
Summary of the content on the page No. 9
D896 AUTOMATIC VENT DAMPER NOTE: If there is a power failure, the damper remains heating contractor for repairs. The name of the original exactly where it is at the moment of failure (open, installer of your vent damper is on the installation label. closed or any position in between). When power is restored, the damper opens if the thermostat is Check vent damper operation as follows: calling for heat or closes if the thermostat is not 1. Turn the thermostat or controller below the room calling
Summary of the content on the page No. 10
D896 AUTOMATIC VENT DAMPER ANSI STANDARDS EXHIBIT A Procedure For Safety Inspection of an Existing Appliance Installation The following procedure is intended as a guide to aid in 10. Determine that the pilot(s), when provided, is burning determining that an appliance is properly installed and is in a properly and that main burner ignition is satisfactory by safe condition for continuing use. interrupting and reestablishing the electrical supply to the appliance in any convenient manner. This pro
Summary of the content on the page No. 11
D896 AUTOMATIC VENT DAMPER EXHIBIT B Procedure for Installing Electrically Operated Automatic Vent Damper Devices on Existing Appliances This procedure is intended as a guide to aid in safely 10. Insofar as is practical, close all building doors and installing an electrically operated or mechanically actuated windows and all doors between the space in which the automatic vent damper device on an existing appliance. appliance is located and other spaces of the building. Turn on clothes dryers. Tu
Summary of the content on the page No. 12
D896 AUTOMATIC VENT DAMPER Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No. 30 Harbour Road Minneapolis MN 55408-0524 M2H 2C9 Wanchai Hong Kong Honeywell Latin American Division Honeywell Europe S.A. Miami Lakes Headquarters 3 Avenue du Bourget 14505 Commerce Way Suite 500 B-1140 Brussels Belgium Miami Lake