Broan QS3 SERIES user manual

User manual for the device Broan QS3 SERIES

Device: Broan QS3 SERIES
Category: Ventilation Hood
Manufacturer: Broan
Size: 2.53 MB
Added : 8/4/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Broan QS3 SERIES. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Broan QS3 SERIES.

For your convenience

If looking through the Broan QS3 SERIES user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Broan QS3 SERIES on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Broan QS3 SERIES to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Broan QS3 SERIES User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Broan QS3 SERIES but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Broan QS3 SERIES. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
ALLURE QS3 SERIES
RANGE HOOD
Page 1
®
ALLURE
Patent No.:
QS3 SERIES RANGE HOOD
US D450, 829 S
READ AND SAVE THESE INSTRUCTIONS
! !
FOR DOMESTIC COOKING ONLY
!
WARNING CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 1. For general ventilating use only. Do not use to exhaust haz-
TO PERSONS, OBSERVE THE FOLLOWING: ardous or explosive materials and vapors.
1. Use this unit only in the manner intended by the manufacturer. If
2. To avoid motor bearing damage and noisy and/or unbalan

Summary of the content on the page No. 2

® ALLURE QS3 SERIES RANGE HOOD Page 2 PREPARE HOOD LOCATION PREPARE THE HOOD ROOF CAP 3¼" X 10" FILTERS (For vertical discharge) SOFFIT HOUSE WIRING CABINET (Top or Back of hood) WALL CAP HOOD H HOOD OOD 1 Remove tape holding Filters in place. Pull down on filter 24" - 30" ABOVE tabs or finger holes and lift filters out. Set filters aside. 3¼" X 10" DUCT COOKING SURFACE (For horizontal discharge) 1 Determine whether hood will discharge vertically (3¼” x 10”), ® or horizontally (3¼” x 10” only

Summary of the content on the page No. 3

➙ ➙ ® ALLURE QS3 SERIES RANGE HOOD Page 3 PREPARE THE HOOD PREPARE THE HOOD AIR CHUTE 6 Remove Air Chute - held in place with one (1) screw. NOTE: Be careful not to disconnect any wires. ELECTRICAL BAFFLE CABLE CLAMP 4 Remove either top or back wiring knockout and install 7 Remove Baffle TABS SLOTS approved Electrical Cable Clamp. from air chute. Tabs will disengage from Slots. Ducted Installation - Skip to Step 11. The following Steps (5 thru 10) are for NON-DUCTED INSTALLATION ONLY. (3) #8 SC

Summary of the content on the page No. 4

➙ ® ALLURE QS3 SERIES RANGE HOOD Page 4 PREPARE THE HOOD PREPARE THE HOOD TIES SCREW TAB BLOWER RETAINING WHEEL RING SMALL DIAMETER END RING SECTIONS MOTOR STOP SLOTS EDGE 10 Non-Ducted Installations Only: Require a Performance Ring to be attached to the blower wheel. To install ring: 1. Remove the Blower Wheel by rocking it side to side and applying a slight force to pull wheel from motor. Remove Retaining Ring if necessary. 2. Slide the ring onto the Small Diameter End of the wheel and down to

Summary of the content on the page No. 5

® ALLURE QS3 SERIES RANGE HOOD Page 5 INSTALL HOOD CONNECT WIRING WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally. HOUSE WIRING (120 VAC) KEYHOLE (4) MOUNTING SCREW (4) 1 Hang hood from (4) Mounting Screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4) CARDBOARD Keyholes. Tighten mounting screws securely. A long (Use to protect screw

Summary of the content on the page No. 6

® ALLURE QS3 SERIES RANGE HOOD Page 6 2. Remove filters, bottom panel, light wire harness, and air chute. NON-DUCTED FILTERS 3. Remove and inspect fuse. If it is not open (blown), additional diag- nostics need to be done. If hood is to be installed Non-Ducted: 4. Install new fuse. Purchase a set of (2) Non-Ducted Filters from your local 5. Re-assemble air chute, light wire harness, bottom panel, and fil- distributor or retailer and attach them to the aluminum mesh ters. filters. 6. Turn on power

Summary of the content on the page No. 7

® ALLURE QS3 SERIES RANGE HOOD Page 7 3 SERVICE PARTS 3 KEY NO. PART NO. DESCRIPTION 4 2 R740013 Damper/Duct Connector (includes hardware) 2 3 R602017 Screw, #8-18 x ¼ Hex* (2 in package) 12 3 4 R334126 Motor Capacitor (includes wire nuts & hardware) 5 6 5 R501031 Isolation Transformer 9 24 6 R627505 Nameplate, White R627506 Nameplate, Almond 8 R627507 Nameplate, Black R627529 Nameplate, Biscuit 7 R169011 Control Panel, White 7 (includes Key No. 6 & hardware) 10 R169012 Control Panel, Almond (in

Summary of the content on the page No. 8

® ALLURE QS3 SERIES RANGE HOOD Page 8 WARRANTY BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at

Summary of the content on the page No. 9

® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® ALLURE QS3 RANGE HOOD Page 9 HOTTE DE CUISINIÈRE DE ® Patent No.: LA SÉRIE ALLURE QS3 US D450, 829 S LISEZ ET CONSERVEZ CES DIRECTIVES ! ! À LA CUISINE DOMESTIQUE SEULEMENT ! AVERTISSEMENT ATTENTION AFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTROCUTION 1. N’utilisez cet appareil que pour la ventilation des surfaces de cuisson. OU DE BLESSURES, SUIVEZ CES DIRECTIVES: Ne l’utilisez pas pour ventiler des matières ou des vapeurs de nature 1.

Summary of the content on the page No. 10

® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 10 PRÉPAREZ L’EMPLACEMENT PRÉPAREZ LA HOTTE CAPUCHON DE TOIT CONDUIT DE 8, 3 CM X 25,4 CM FILTRES (Pour évacuation verticale) SOFFITE FIL DU PANNEAU D'ALIMENTATION ÉLECTRIQUE (Branché sur le dessus ou à l'arrière de la hotte) ARMOIRE CAPUCHON DE MUR HOTTE HOTTE HOTTE 60 CM À 76 CM CONDUIT DE 8, 3 CM X 25, 4 CM AU-DESSUS DE LA SURFACE 1 Retirez le ruban adhésif qui sert à maintenir les filtres en place. (Pour

Summary of the content on the page No. 11

➙ ➙ ® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 11 PRÉPAREZ LA HOTTE PRÉPAREZ LA HOTTE CHUTE D’AIR 6 Enlevez le chute d’air - maintenue par une (1) vis. REMARQUE : Prendre garde de ne débrancher aucun fil. DÉFLECTEUR 7 Enlevez le déflecteur de la COLLET DE FIXATION DU CÂBLE ONGLETS chute d’air. Les FENTES D’ALIMENTATION onglets 4 Retirez l’une des deux débouchures d’accès du câble désengageront d’alimentation (sur le dessus de la hotte ou à l’arrière) et des

Summary of the content on the page No. 12

➙ ® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 12 PRÉPAREZ LA HOTTE PRÉPAREZ LA HOTTE ATTACHES VIS PATTE ROUE DU ANNEAU VENTILATEUR EXTRÉMITÉ DE DE COMPRESSION FAIBLE DIAMÈTRE ANNEAU SECTIONS FENTES DU BORD MOTEUR LIMITE 10 Pour installations sans conduit seulement : Vous devez installer un anneau de puissance sur la roue du ventilateur. Pour installer cet anneau : 1. Retirez la roue du ventilateur en tirant de façon modérée et en la bougeant pour la désenga

Summary of the content on the page No. 13

® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 13 BRANCHEZ LES FILS INSTALLEZ LA HOTTE D’ALIMENTATION ÉLECTRIQUE AVERTISSEMENT: Afin de prévenir les risques d’électrocution, assurez-vous que le courant ait été interrompu au panneau d’alimentation principal. Verrouillez ce dernier ou apposez un indicateur voyant pour éviter que quelqu’un ne remette accidentellement le courant en marche. CÂBLE D’ALIMENTATION DU PANNEAU OUVERTURE EN FORME DE OUVERTURE EN FORME DE

Summary of the content on the page No. 14

® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 14 3. Enlever et inspecter le fusible. S’il n’a pas sauté (grillé), un diagnostic plus poussé FILTRES SANS CONDUIT doit être effectué. 4. Installer le nouveau fusible. Si la hotte est installée sans conduit: 5. Remonter le volet d’évacuation, le connecteur de la lumière, le panneau inférieur et les filtres. Procurez-vous un ensemble de 2 filtres pour installation non 6. Rétablir le courant et vérifier le fonctionnem

Summary of the content on the page No. 15

® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 15 PIÈCES DE REMPLACEMENT 3 3 NO. DU NO. DE 4 SCHEMA PIECE DESCRIPTION 2 2 R740013 Raccord du conduit avec le registre (avec vis d’assemblage) 12 3 3 R602017 Vis # 8-18 x ¼ six pans* (2) 5 6 4 R334126 Condensateur pour moteur (avec serre-fils et vis d’assemblage) 9 24 5 R501031 Transformateur d’isolement 6 R627505 Plaque d’identification, blanche 8 R627506 Plaque d’identification, amande R627507 Plaque d’identifica

Summary of the content on the page No. 16

® HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE QS3 SERIES ® RANGE HOOD ALLURE QS3 Page 16 GARANTIE GARANTIE LIMITÉE D’UN AN DE BROAN-NUTONE Broan-NuTone garantit à l’acheteur consommateur original de ses produits qu’ils sont exempts de vice de matériaux ou de fabrication pour une période d’un an à compter de la date d’achat original. IL N’Y A PAS D’AUTRES GARANTIES, EXPRIMÉES OU IMPLICITES, INCLUANT MAIS NON LIMITÉES AUX GARANTIES IMPLICITES DE QUALITÉ MARCHANDE ET DE CONVENANCE DANS UN BUT PARTICULI


Alternative user manuals
# User manual Category Download
1 Broan 356BR User manual Ventilation Hood 5
2 Broan 355BR User manual Ventilation Hood 0
3 Broan 350BR User manual Ventilation Hood 2
4 Broan 46000 User manual Ventilation Hood 1
5 Broan 350BK User manual Ventilation Hood 0
6 Broan 4-Way Convertible Range Hood QL1 Series User manual Ventilation Hood 9
7 Broan 356BK User manual Ventilation Hood 0
8 Broan 355BK User manual Ventilation Hood 1
9 Broan 61000EX User manual Ventilation Hood 0
10 Broan 684 User manual Ventilation Hood 0
11 Broan 63000EX User manual Ventilation Hood 1
12 Broan ALLURE QS3 User manual Ventilation Hood 3
13 Broan 778WH User manual Ventilation Hood 0
14 Broan 758 User manual Ventilation Hood 0
15 Broan 629004 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0