Summary of the content on the page No. 1
INSTALLATION INSTRUCTIONS
HB0031
MODELS RMIP33 AND RMIP45
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
REGISTER YOUR PRODUCT ON LINE A
Summary of the content on the page No. 2
! WARNING ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO PERSONS SHOCK OR INJURY TO PERSONS, OBSERVE IN THE EVENT OF A RANGE TOP GREASE THE FOLLOWING: FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the 1. SMOTHER FLAMES with a close-fitting lid, manufacturer. If you have questions, contact the cookie sheet or metal tray, then turn off the manufacturer at the address or telephone number burner. BE CAREFUL TO PREVENT BURNS. IF listed
Summary of the content on the page No. 3
- RMIP33 AND RMIP45 INSERT SYSTEM - INTERIOR BLOWERS Model 647 Model 643 (7” Rd wall cap) (8” Rd wall cap) Model 634 or 644 8” Rd (roof cap) Model 415 adjustable 7” Rd adjustable elbow (optional) elbow (optional) 8” Rd Model 407 standard (7” Rd x 24’’ duct section) 8” Rd metal 7” Rd metal flexible duct flexible duct (optional) (optional) Model 412 Model 413 Model 459 transition transition transition 1 1 (3 /4” x 10” to 7”) 1 (3 /4” x 10” to 8”) (3 /4” x 14” to 8”) 1 Adapter and damper 3 /4’’
Summary of the content on the page No. 4
- RMIP33 AND RMIP45 INSERT SYSTEM - IN-LINE AND EXTERIOR BLOWERS Model 441 Model 437 (10” Rd wall cap) (High capacity roof cap) Model HLB9 (800 cfm) Model 335 (1200 cfm) or HLB11 (1100 cfm) or 336 (1500 cfm) in-line blower exterior blower Model 331H (600 cfm) (includes two 8” x 12” to or 332H (900 cfm) 10’’ round transitions) exterior blower Model 441 (10” Rd wall cap) Model HLB6 (600 cfm) in-line blower (includes two 4½” x 18½” to 10’’ round transitions) Model 421 Model 418 (10” Rd. vert. 10”
Summary of the content on the page No. 5
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in-line blower may be used with this insert. The insert model RMIP33 or RMIP45 must be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately). Plan where and how the ductwork will be installed. Access to the top of the hood is preferred for connection of ductwork. As an alternative, flexible metal ductwork may be
Summary of the content on the page No. 6
3. INSTALL BACKSPLASH (OPTIONAL) It is recommended to install the backsplash before the custom hood insert. The custom hood will cover the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of custom hood and range control panel or cooktop. (See instructions packed with backsplash.) 4. CUSTOM HOOD PREPARATION ! WARNING When building a custom hood, always follow all applicable construction codes and standards. T
Summary of the content on the page No. 7
6. INSTALL CUSTOM HOOD LINER (OPTIONAL) The liners are specially designed to protect the exterior base of the custom hood. To order, refer to the table below to find the right liner model number for your insert and width of custom hood. To view specific model information, including depths for each liner models, visit www.broan.com or contact Technical Support (phone number listed on front cover). To install, see instruction packed with custom hood liner. The liner must be installed before the in
Summary of the content on the page No. 8
10. REMOVE THE KNOCK-OUT OPENING (INTERIOR BLOWER) Remove the knockout on rough-in plate. See picture below. CAUTION When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’ adapter/damper). HD0077 Removing vertical knockout opening on rough-in plate 11. INSTALL THE DEVIATOR (INTERIOR BLOWER) Install the deviator as shown. NOTE: To prevent the deviator from sliding out of the rough-in plate,
Summary of the content on the page No. 9
13. CONNECT WIRING (ALL BLOWERS) ! WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Position insert below the installed custom hood. Pull cable through hole in top of insert. INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Rem
Summary of the content on the page No. 10
16. DUCTING CONNECTION (ALL BLOWERS) A. When there is access to the top of the hood, connect ductwork and seal connections with duct tape after Step 17 Install the insert. B. When there is no access to the top of the hood, carefully pull down the metal duct through the custom hood base hole. Slide this duct over the transition (interior blower) or over the flange of the rough-in plate (in-line or exterior blower). Make sure the adapter/damper assembly enters the ducting. Seal the connection
Summary of the content on the page No. 11
18. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D) Install (4) no. 8 x 3/8’’ screws into the location as shown in the pictures below (single blower or dual blower). Do not tight- en screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the key- hole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the (4) screws. HD0044 HD0045 Single blower (P5) Dual blower (P8) Secure the blower by installing 2 more no. 8 x
Summary of the content on the page No. 12
19. LIGHT BULBS This insert uses 50W halogen lamps (120V, 50W, PAR 20) (Purchase separately). Install the lamps by rotating them clockwise into their socket holder. 20. INSTALL FILTERS It is recommended to install side filters first and finish with center one(s). 1.Insert upper end of filter into the insert (finger sized cup side). 2.Raise lower end of filter to position it into grease rail inside of hood and pull. 3.While pulling the filter, slide it under the inner retaining piece. Replacement
Summary of the content on the page No. 13
21. USE AND CARE (CONT’D) Avoid: when choosing a detergent - Any cleaners that contain bleach will attack stainless steel. - Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly. - Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range. 22. OPERATION Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Let the blo
Summary of the content on the page No. 14
WARRANTY BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone LLC will, at its option, repair or re
Summary of the content on the page No. 15
SERVICE PARTS SINGLE BLOWER/ROUGH-IN (Model P5) 1 20 21 2 22 23 19 3 4 18 17 5 7 16 15 6 14 8 13 6 12 9 11 10 HL0021 KEY PART NUMBER DESCRIPTION QTY NO. 1 1 V13296 ADAPTER AND DAMPER 3 1/4’’ x 10’’ 1 2 V03500 AIR DEFLECTOR 1 3 V12997 SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY 1 4 V03577 FOAM 1/2” X 1/2” X 12” 1 5 V02160 CAPACITOR 15MFD 4 6 V01869 MACHINE SCREW NO. 6-32 X 1/4” 1 7 V01857 WIRE COVER 1 8 V01582 LOCK NUT NO. 6-32 1 9 V14973 SINGLE BLOWER ASSEMBLY 1 10 V01810 IMPELLER RING 1 11 V03
Summary of the content on the page No. 16
SERVICE PARTS DUAL BLOWER/ROUGH-IN 2 (Model P8) 22 24 1 23 25 3 4 21 5 20 19 18 6 17 16 7 15 14 8 9 11 13 10 12 HL0022 KEY PART NUMBER DESCRIPTION QTY NO. 1 1 V14971 ADAPTER AND DAMPER 3 1/4 ‘’ x 14’’ 1 2 V13296 ADAPTER AND DAMPER 3 1/4 ‘’ x 10’’ 1 3 V03500 AIR DEFLECTOR 1 4 V14975 DUAL BLOWER ROUGH-IN PLATE ASSEMBLY 1 5 V03577 FOAM 1/2” X 1/2” X 12” 1 6 V01582 LOCK NUT NO. 6-32 2 7 V02160 CAPACITOR 15MFD 2 8 V01857 WIRE COVER 1 9 V01766 MOTOR 165W CW 1 10 V03400 BLOWER IMPELLE