Air King In-Line Exhaust Fan AIK26YF user manual

User manual for the device Air King In-Line Exhaust Fan AIK26YF

Device: Air King In-Line Exhaust Fan AIK26YF
Category: Ventilation Hood
Manufacturer: Air King
Size: 0.23 MB
Added : 10/4/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Air King In-Line Exhaust Fan AIK26YF. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Air King In-Line Exhaust Fan AIK26YF.

For your convenience

If looking through the Air King In-Line Exhaust Fan AIK26YF user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Air King In-Line Exhaust Fan AIK26YF on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Air King In-Line Exhaust Fan AIK26YF to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Air King In-Line Exhaust Fan AIK26YF User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Air King In-Line Exhaust Fan AIK26YF but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Air King In-Line Exhaust Fan AIK26YF. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
In-Line Exhaust Fan
Models: AIK14XL, AIK26YL, AIG46HL,
AIG46F, AIK14XF, AIK26YF
with Light
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using

Summary of the content on the page No. 2

INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. Fan SECTION 1 Preparing for Fan Installation 1. When selecting fan mounting location, the following criteria Stud should be considered: a) Mounting to minimize noise generated by fan operation: Mounting the fan as far as possible from the intake point will minimize fan operating noise from being Screws transmitted back through the duct work. If the fan is to Bracket Figure 2 be used

Summary of the content on the page No. 3

Install the rails on the housing and position the housing grill Housing Joist collar in the previously cut hole so that it is flush with the finished ceiling (Figure 8). Secure the ends of the rails to the joists (Figure 4). Housing Locating Tabs Mounting Rails Figure 4 6" NOTE: If drywall or ceiling material will be thicker than 5/8" the Figure 7 height of the housing will need to be adjusted to compensate and the locator tabs will need to be bent even with the housing to Housing allow the gril

Summary of the content on the page No. 4

NOTE: Units that include only one collar do not utilize the “Y” Housing transition. Follow the same instructions as in step 1, except Joist connect the one end of the ducting directly to the fan. 2. Connect one end of the ducting to the top of the “Y” transition and the other end to the intake of the fan (Figure 11). Ceiling 3. Connect one end of the ducting to the exhaust of the fan and the other end to a wall or ceiling cap. (Figure 11). Always duct the fan to the outside through a wall or roo

Summary of the content on the page No. 5

Black/Red CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. SERVICES OF A QUALIFIED ELECTRICIAN. 1. Remove the

Summary of the content on the page No. 6

1. Cleaning the Grill: Remove grill and use a mild detergent, Housing such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 10 Completing the Installation, to reinstall grill. Ceiling/Wall Lamp 2. The fan’s bearings are sealed and provided with an internal lubricating material, no additional lubrication is necessary. CAUTION: ALLOW LAMP TO COOL BEFORE REPLACING. 3. Changin

Summary of the content on the page No. 7

LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and/or material. This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance

Summary of the content on the page No. 8

REPLACEMENT PARTS DIAGRAM 3 1 10 2 9 8 16 11 7 15 12 5 17 14 4 13 6 Halogen Lamp Fan Kit Replacement Parts Fluorescent Lamp Fan Kit Replacement Parts # Qty. Description Replacement Part # # Qty. Description Replacement Part # 1 1 Motor - AIK14XL 5S7635038 1 1 Motor - AIK14XF 5S7635038 1 Motor - AIK26YL 5S7635002 1 Motor - AIK26YF 5S7635002 2 1 Cover Plate - AIK14XL 5S7635029 2 1 Cover Plate - AIK14XF 5S7635029 1 Cover Plate - AIK26YL 5S7635030 1 Cover Plate - AIK26YF 5S7635030 3 2 Screw 5S769902

Summary of the content on the page No. 9

INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Ventilateur d’évacuation en Modèles: AIK14XL, AIK26YL, AIG46HL, AIG46F, AIK14XF, AIK26YF série avec lumière LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À LA PROPRIÉTÉ. CONSERVER CES IN

Summary of the content on the page No. 10

INSTRUCTIONS D’INSTALLATION Montant AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER Ventilateur L’INSTALLATION. SECTION 1 Préparation en prévision de l’installation du ventilateur 1. Lorsque vous choisissez l’emplacement pour l’installation du ventilateur, les critères suivants doivent être pris en compte : a) Installation visant à réduire le bruit généré par le Vis fonctionnement du ventilateur : L’installation du ventilateur Support Figure 2 a

Summary of the content on the page No. 11

Châssis SECTION 5 Solive Construction Existante 1. Installation des traverses de montage : Déterminez l’emplacement de la grille et découpez une ouverture circulaire de 152,4 mm en faisant attention de ne pas couper ou endommager des composantes électriques ou tout ou autre Châssis matériel dissimulé (Figure 7). Installez les traverses sur le châssis Onglets de et placez le collet du châssis de la grille dans l’ouverture découpée localisation de sorte qu’elle soit à effleurement du plafond final

Summary of the content on the page No. 12

REMARQUE : Si l’épaisseur de la paroi sèche ou du matériel du Evacuation vers plafond est de plus de 15,88 mm, la hauteur du châssis devra être le capuchon du ajustée pour compenser et les onglets de repère pliés à égalité mur / plafond du châssis de sorte que le collet de la grille soit à effleurement du matériel de plafond final. Châssis Ventilateur Solive Embranchement Plafond Châssis de en “ Y ” la grille Châssis de la grille Figure 10 Conduit Figure 11 SECTION 6 Conduit REMARQUE : Les unité

Summary of the content on the page No. 13

Noir/Rouge 3. Insérez l’arbre du clapet dans le trou perforé à l’étape 2. Alimentation provenant de la maison Placez la rondelle, la poignée et ensuite l’écrou à oreille dans l’arbre (Figure 12). Blanc Ecrou à Bleu oreille Poignée N Noir Rondelle Arbre L Trou Rouge Clapet Brun Embranchement Figure 14 en “ Y ” 4. Assurez-vous que toutes les connexions de câblage sont Figure 12 fixées de manière sécuritaire à la plaquette de connexions et replacez le couvercle du boîtier de raccordement. 4. Ajuste

Summary of the content on the page No. 14

2. Installez la grille dans le châssis de la grille de plafond en la Fil de Masse poussant fermement vers l’intérieur, vers le châssis, jusqu’à ce qu’elle soit à effleurement du matériau du mur ou du plafond. (Figure 17). Blanc Fil Chaud 3. Rétablissez le courant et testez votre installation. (Noir) SECTION 11 Figure 16 Utilisation et entretien AVERTISSEMENT : ASSUREZ-VOUS QUE LE COURANT 4. Installez à nouveau le couvercle électrique en vous assurant EST COUPE A PARTIR DU PANNEAU ELECTRIQUE AVAN

Summary of the content on the page No. 15

GARANTIE LIMITÉE Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. Cette garantie ne couvre pas de coûts de transport ou de main d’œuvre ou l

Summary of the content on the page No. 16

DIAGRAMME DES PIÈCES DE REMPLACEMENT 3 1 10 2 9 8 16 11 7 15 12 5 17 14 4 13 6 Pièces de remplacement pour ensemble de Pièces de remplacement pour ensemble de ventilateur à lumière à halogène ventilateur à lampe fluorescente # de pièce # de pièce # Qté. Description de remplacement # Qté. Description de remplacement 1 1 Moteur - AIK14XL 5S7635038 1 1 Moteur - AIK14XF 5S7635038 1 Moteur - AIK26YL 5S7635002 1 Moteur - AIK26YF 5S7635002 2 1 Plaque de finition - AIK14XL 5S7635029 2 1 Plaque de finiti


Alternative user manuals
# User manual Category Download
1 Air King AIF8X User manual Ventilation Hood 3
2 Air King AIF10X User manual Ventilation Hood 0
3 Air King 500CFM User manual Ventilation Hood 0
4 Air King AIK14X User manual Ventilation Hood 0
5 Air King 380 CFM User manual Ventilation Hood 38
6 Air King AD series User manual Ventilation Hood 1
7 Air King AIG6 User manual Ventilation Hood 0
8 Air King AIK24Y User manual Ventilation Hood 0
9 Air King AIF6Y User manual Ventilation Hood 0
10 Air King AK200LS User manual Ventilation Hood 0
11 Air King AK863FL User manual Ventilation Hood 0
12 Air King AK100LSL User manual Ventilation Hood 1
13 Air King AK965FL User manual Ventilation Hood 2
14 Air King AK960 User manual Ventilation Hood 0
15 Air King AK100L User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0