Summary of the content on the page No. 1
www.zephyronline.com
Cypress
AK7836ASX
AK7842ASX
AK7848ASX
INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA.
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
AUG08.0101 © Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS
Use, Care, and Installation Guide
Summary of the content on the page No. 2
www.zephyronline.com
Summary of the content on the page No. 3
SAFETY NOTICE ................................................................. 2-3 LIST OF MATERIALS ....................................................... 4 INSTALLATION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ........................................................... 7 Specifi cations ............................................................... 8 Electrical ..........................
Summary of the content on the page No. 4
READ AND SAVE THESE INSTRUCTIONS www.zephyronline.com WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being swit
Summary of the content on the page No. 5
WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair, fi ngers and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installat
Summary of the content on the page No. 6
www.zephyronline.com MODELS: AK7836ASX, AK7842ASX, AK7848ASX PARTS SUPPLIED 1 - Hood 3 - Baffl e fi lters (4 for AK7848ASX) 2 - Halogen light bulbs (3 for AK7548ASX) (pre-installed) 1 - 10” round transition adapter (for dual internal and external blowers) 1 - External blower wiring (for external and in-line blower) 1 - Hardware package HARDWARE PACKAGE CONTENTS Suction Cup (1) M4 x 2” (4) M4 x 1-1/2” (4) M4 x 1” (4) M4 x 8 (4) M4 x 16 (4) Wire Caps (3) PARTS NOT SUPPLIED - Ducting, conduit and al
Summary of the content on the page No. 7
Equivalent number Duct pieces Equivalent number Duct pieces length x used = Tota l length x used = Tota l 3-1/ 4” x 10” 1 Ft. x ( ) = Ft. Ft. 6” Round 30 Ft. x ( ) = Rect., wall cap straight with damper 6” Round, 1 Ft. x ( ) = Ft. 6” Round, Ft. 30 Ft. x ( ) = straight roof cap 7”-10” Round, 1 Ft. x ( ) = Ft. Ft. 6” round to 1 Ft. x ( ) = straight 3-1/ 4” x 10” rect. transition Ft. 3-1/ 4” x 10” 15 Ft. x ( ) = 6”
Summary of the content on the page No. 8
www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 30”. Maximum mount height should be no higher than 12”* 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could 18" result in heat damage and fi re hazard; while hoods mounted too high will be hard to reach and will lose its performance and effi ciency. If available, also refer range manufacturer’s height Min 30" - Max 36" clearance requirements and
Summary of the content on the page No. 9
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options Roof Pitch w/ External Flashing & Cap Blower Side wall cap w/ gravity damper In-Line Blower Side wall cap w/ gravity damper Soffit or crawl space 7 Installation – Ducting
Summary of the content on the page No. 10
www.zephyronline.com Marine Grade 316S Body 12” 13 3/16” *10 ” 2 5/16” 1 1/8” 2 1/16” 4 5/16” 2” 5 9/16” 8 9/16” 2 11/16” 6 7/16” 18” ext elec 4” C L blwr k/o k/o 27” *10” transition used with dual, external and in-line blowers. top side 2” 5-7/8” 35 15/16” (36”) 41 15/16” (42”) 47 15/16” (48”) front 8 Installation – Specifi cations
Summary of the content on the page No. 11
ELECTRICAL WARNING All Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded b
Summary of the content on the page No. 12
www.zephyronline.com ! CAUTION: At least two installers are required due to the weight and size of the C/L hood. 1. Measure distance from range top to hood bottom (30” min) Level B wood board and mark line A. 4” 2. Plum and mark center line. 12 3/8” 3. Mark mounting height line B. (12 3/8” from line A) (This is the top of the board used to hang the hood) A 4. Mark center line of wood board and align top of board with line B. Secure wood board to studs using (4) M4 wood screws. Wood Board
Summary of the content on the page No. 13
CBI-600B AND PBI-1100A BLOWER INSTALLATION 1. Position blower plate over bracket on inside 2. Connect male end of blower wire to female plug back of hood and pivot up. Secure plate to hood in the hood. (plug is located inside the hood with (2) 10x3/16” screws. (blower pictured is a behind the control panel) PBI-1100A) 3. Single Blower – Connect 6” round duct work to blower collar. Dual Blower – Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct w
Summary of the content on the page No. 14
www.zephyronline.com CBE-1000 EXTERNAL OR PBN-1000A IN-LINE BLOWER INSTALLATION 2. Install threaded end of external blower wiring 1. Place 10” round adapter on top of hood and through external blower wiring knock out secure with (4) M4x8 screws. Connect 10” located inside the hood. round duct work to 10” round adapter. 3. Place cap over threaded end of external blower 4. Connect 6 pin male connector from external wiring and secure by turning clockwise. blower wiring to 6 pin female connect
Summary of the content on the page No. 15
1 Lights On/Off 2 Adjust Blower Level (2 Speeds) 1 Light On/Off By pressing , the light is switched On and Off. is on, is off. 2 Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Switching the rocker switch to middle will turn off the blower. 13 Features & Controls – Rocker Switch Controls
Summary of the content on the page No. 16
www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly using a micro fi ber or
Summary of the content on the page No. 17
REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are diffi cult to turn due to prolonged use, fi rmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove
Summary of the content on the page No. 18
www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2. Check the power connection with the unit is is not connecting properly. connected properly. 3. The switch board and control board wirings are 3. Make sure the wirings between the switch disconnected. board and control b
Summary of the content on the page No. 19
DESCRIPTION PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baffl e Filter (each) 50210009 Optional Accessories Single Internal Blower CBI-600B Dual Internal Blower PBI-1100A External Blower CBE-1000 In-Line Blower PBN-1000A Vinyl Cover (36”) AK0636AB Vinyl Cover (42”) AK0642AB Vinyl Cover (48”) AK0648AB 12” Duct Cover (36”) AK0736AS 12” Duct Cover (42”) AK0742AS 12” Duct Cover (48”) AK0748AS To order parts, visit us online at http://store.zep