Zephyr CTP-E 60SX user manual

User manual for the device Zephyr CTP-E 60SX

Device: Zephyr CTP-E 60SX
Category: Ventilation Hood
Manufacturer: Zephyr
Size: 0.66 MB
Added : 6/14/2013
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Zephyr CTP-E 60SX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Zephyr CTP-E 60SX.

For your convenience

If looking through the Zephyr CTP-E 60SX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Zephyr CTP-E 60SX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Zephyr CTP-E 60SX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Zephyr CTP-E 60SX User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Zephyr CTP-E 60SX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Zephyr CTP-E 60SX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.zephyronline.com
Trapeze
CTP-E 48SX
CTP-E54SX
CTP-E 60SX
Model number:
Serial number:
Date of Purchase:
Sales Dealer:
© Zephyr Corporation.
MAY07.0101
Use, Care, and Installation Guide

Summary of the content on the page No. 2

www.zephyronline.com

Summary of the content on the page No. 3

SAFETY NOTICE .............................................. 2 LIST OF MATERIALS ....................................... 3 INSTALLATION Ducting Calculation Sheet ............................... 4 Mounting Height and Clearance ..................... 5 Ducting .................................................................. 6 Specifications ....................................................... 7 Internal Blower .................................................... 8 - 9 Prepar

Summary of the content on the page No. 4

www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE TH E R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT USE TH IS FAN W ITH ANY S O LID-S TATE SPE E D CONTROL DEV IC E. WARNING TO RE DUCE TH E R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO P E R SON S, O B S E RVE TH E FO LLOW ING: a. Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer. b. Before servicing or cleaning unit, switch power off at service panel

Summary of the content on the page No. 5

MODEL: CTP-ExxS 1 - Hood 2 - Baffle Filters 4 - GU-10, 120V 50 W, halogen bulbs 2 - Utensil Rails 2 - Telescopic Duct Covers 4 - Telescopic Rods Sets 4 - Angle Bra ckets (27 3/8”) 4 - Angle Bra ckets (35 3/8”) 1 - Ceiling MountingBra cket 1 - Internal Flange 1 - Motor Housing 1 - HARDWARE PACKET 4 - Couplers 4 - Anchors 4 - 2” Wood Screws 4 - 2 1/2” Wood Screws 4 - 1/2” Washers 26 - 1/2” Self Tapping Screws 4 - 1/2” Screws 5x15mm 4 - 5mm Internal Diameter Washers 4 - Adhesive Fasteners 4 - Cable

Summary of the content on the page No. 6

www.zephyronline.com Equivalent number Equivalent number Duct pieces Duct pieces length x used = Total length x used = Total 31/4”x10” 1 Ft. x ( ) = Ft. Ft. 6” Round 30 Ft. x ( ) = Rect., wall cap straight with damper 7” Round, 1 Ft. x ( ) = Ft. 6” Round, 30 Ft. x ( ) = Ft. straight roof cap Ft. 7” Round, 1 Ft. x ( ) = 6” round to 1 Ft. x ( ) = Ft. straight 31/4”x10” rect. transition 31/4”x1

Summary of the content on the page No. 7

Minimummountheight between range top to hood bot- tom should be no less than 28". Maximum mountheight should be no higher than 36". Min 34"-Max 52" It is importantto install the hood at the proper mounting height. Hoods mountedtoo low could result in heat damage and fire hazard; while hoods mountedtoo high will be hard to reach and will loose its performance and efficiency. 9" If available, also refer to range manufacturer's height clearance requirements and recommendedhood Min 28"-Max 36" mount

Summary of the content on the page No. 8

www.zephyronline.com WARNING FIRE HAZARD NEV E R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape. Some Ducting Options: External Blower side wall cap w/ gravity damper Soffit or crawl space RoofPitch w/ Flashing& Cap External Blower Soffit or crawl space

Summary of the content on the page No. 9

13/8” R 41/8” 9“ 32“ 15 3/4” 26 5/8” 11 3/4“ 32” 10“ 9“ 2” Min 21” - Max 40” 7/64” 12 1/8” 13/32” 2” 48” , 54” , 59 1/8” 7 O 1021/64” 6“ 9“ Min 34“ - Max 52” 107/16” 91/2” 15/32” 9“ Installation-Specifications

Summary of the content on the page No. 10

www.zephyronline.com ATTENTION The following are intructions for installing internal blower model CBI-600. For instructions on preparing for external blower model CBE-1000 please turn to page “10”. Before installing, verify that motor spins freely. The internal blower kit consists of the blower 1. Remove existing screws from blower and capacitor box with wiring. housing. 2. Att ach capacitor box to blower housing 3. Att ach motor connector to capacitor box using the removed screws. connector. 4

Summary of the content on the page No. 11

6. Attach junction box to internal flange using 7. Attach grounding wires from junction box provided 1/2” self tapping screws and 4mm and motor to grounding screw as shown. internal diameter washers. 8. Place blower with attached flange into 9. Attach using 1/2” self tapping screws to motor housing as shown on Fig-A. secure in place. 10. Att ach other end of capacitor box connector and junction box connector to control board box and wiring box connector inside hood. Continue to page “11” for hoo

Summary of the content on the page No. 12

www.zephyronline.com ATTENTION The following are instructions on preparing your hood for installation with external blower model CBE-1000. For instructions on installing internal blower model CBI-600 please turn to page “8”. The external blower kit consists of an 8” 1. P osition and attach external blower wiring collar, external flange and external blower box and junction box using provided 1/2” self wiring box. The external blower is purchased tapping screws and 4mm internal diameter separately

Summary of the content on the page No. 13

Ceiling CL Mounting Holes Marking for Coupler Narrow End CL Tabs Add Blockings Tabs Ceiling Bracket 1. Using the cardboard template from top of box, mark the center point in between the (4) mounting holes. Determine the location for mounting your hood, place template on ceiling and mark/drill the center point for the ceiling mounting bracket and the foud corner holes where the telescopic rod couplers will attach to the ceiling. 2. Cut out hole for the duct work. 3. Add and secure wood blocking

Summary of the content on the page No. 14

www.zephyronline.com 1. Mount motor housing to the range hood b ody using (10) 1/2” self tapping screws. 2. Determine height of hood, measure and select either 27 3/8” or 35 3/8” angle brac kets and attach (4) of them to the motor housing using (8) 1/2” self tapping screws (2) for each angle bracket. 3. Slide duct covers over motor housing. Make sure bottom duct cover with cut-out is facing the front and back of the hood. 12 Installation - Mounting the Hood

Summary of the content on the page No. 15

Tab [a] Ductwork Electrical wiring [b] 5. Lift assembled unit and attach all (4) angle brackets to ceiling bracket. Make sure the tabs on each angle brackets are facing the outside. The angle brackets will fit between the slots on the ceiling bracket. One half of the angle bracket will be on the outside of the ceiling bracket and the other half will be on the inside of the ceiling bracket. Attach using provided1/2” self tappingscrews. Re fer to diagram [a]. 6. Slide duct covers up and attach d

Summary of the content on the page No. 16

www.zephyronline.com TelescopicRodInstallation Set 1. Install telescopic rod (thicker end down) into coupler screws on top of hood and secure with medium set screw. Attach screw using provided tool. 2. Extend telescopic rod towards the ceiling and insert thin end of rod into ceiling coupler. Attach a medium set screw in the middle where the two rods attach to each other. 3. Attach medium set screw into the ceiling coupler to secure it in place. Repeat these steps for each telescopic rod. Tool Se

Summary of the content on the page No. 17

www.zephyronline.com 1. Blower On/Off By pressing , the blower is switched On and Off. 2. Speed Selection The 3 speed levels are selected by presing to decrease and to increase speed level. T he display indicates level selected. 3. Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated. Press once, a dot flashes in the lower right hand side of display indicating the function is on. The hood will completely

Summary of the content on the page No. 18

FilterCleanReminder(StandardBaffleFiltersfitted): A set of baffle filters are fitted by the factory. These Baffle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The FilterCleanReminder function in the microprocessor will automatically indicate by a flashing when the metal filters need to be cleaned after every 30 hrs. of use. Filters can be cleaned by hand with non-abrasive soap or in a dishwashe

Summary of the content on the page No. 19

www.zephyronline.com Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine ble

Summary of the content on the page No. 20

ReplacingLightBulbs: CAUTION: Lightbulbsbecomeextremelyhotwhenturnedon. DONOT touchbulbsuntilswitchedoff andcooled.Touchinghotbulbsmaycauseseriousburns. Make sure all power is turned off and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the light socket will now extend from the hood allowing you to remove the bulb.(Becarefulwhenreleasingretainingclipasitisunderpressuretoholditinplace) Replacement bulbs are available at most stores which sell light bul


Alternative user manuals
# User manual Category Download
1 Zephyr AK11005 User manual Ventilation Hood 2
2 Zephyr AK7500ASX User manual Ventilation Hood 0
3 Zephyr AK7548ASX User manual Ventilation Hood 0
4 Zephyr AK11245 User manual Ventilation Hood 1
5 Zephyr AK8100AS User manual Ventilation Hood 1
6 Zephyr AK11365 User manual Ventilation Hood 0
7 Zephyr AK8100S User manual Ventilation Hood 0
8 Zephyr AK7536ASX User manual Ventilation Hood 1
9 Zephyr AK8000AS User manual Ventilation Hood 1
10 Zephyr AK8200AS User manual Ventilation Hood 2
11 Zephyr AK8300ASX User manual Ventilation Hood 1
12 Zephyr ALL-E42ABX User manual Ventilation Hood 0
13 Zephyr ALL-E42AW X User manual Ventilation Hood 0
14 Zephyr ALL-M90ABX User manual Ventilation Hood 1
15 Zephyr APN-M90ABX User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0