Zephyr CPA-E42ASX user manual

User manual for the device Zephyr CPA-E42ASX

Device: Zephyr CPA-E42ASX
Category: Ventilation Hood
Manufacturer: Zephyr
Size: 1.78 MB
Added : 6/14/2013
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Zephyr CPA-E42ASX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Zephyr CPA-E42ASX.

For your convenience

If looking through the Zephyr CPA-E42ASX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Zephyr CPA-E42ASX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Zephyr CPA-E42ASX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Zephyr CPA-E42ASX User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Zephyr CPA-E42ASX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Zephyr CPA-E42ASX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.zephyronline.com
Padova
CPA - E42ASX
CPA - E48ASX
CPA - E54ASX
Model number:
Numéro de modèle: ____________________________________
Número de modelo:
Serial number:
Numéro de série: _____________________________________
Número de serie:
Date of Purchase:
Date d’achat: _____________________________________
Fecha de compra:
Sales Dealer:
Détaillant: _____________________________________
Distribuidor:
LI2ZRA - DEC06.0101
READ AND SAVE THESE INSTRUCTIONS
LISEZ CES INSTRUCTIONS ET CONSERVEZ-L

Summary of the content on the page No. 2

English page 2 French page 28 Spanish page 56 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Safety Warning: Turn off power circuit at service

Summary of the content on the page No. 3

www.zephyronline.com Important Safety Notice .................................................................... 5 Electrical & Installation Requirements ............................................ 6 Electrical requirements .............................................................. 6 Before installing the hood ........................................................... 6 List of Materials ................................................................................. 7 Parts supplied ...

Summary of the content on the page No. 4

Installation - Installing the Duct Covers ......................................... 18 Installation - Hanging the Hood onto the Wall .............................. 19 Installation - Electrical Connection & Final Installation Steps ..... 20 Electrical connection ................................................................ 20 Description of the Hood .................................................................. 21 Features & Controls - Touch Controls & Features ........................ 22

Summary of the content on the page No. 5

READ AND SAVE THESE INSTRUCTIONS www.zephyronline.com CAUTION FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to pr

Summary of the content on the page No. 6

ELECTRICAL REQUIREMENTS IMPORTANT Observe all governing codes and ordinances. It is the customer’s responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended

Summary of the content on the page No. 7

www.zephyronline.com PARTS SUPPLIED • Hood body, with stainless steel baffle filter and halogen light bulbs and incandescent lamp already installed • Two telescopic duct covers and support bracket • Hardware Packet: - 24x53 T1T2 "L" Male monkey spanner (1 piece) - 3.5X9.5 screws to fix the internal blower (4 pieces) - 3.5X9.5 screws to fix the duct cover (4 pieces) - 3.5X9.5 screws to fix the 8" collar plastic round transition duct cover (4 pieces) - 4x8 screws to fix the external blower wiring

Summary of the content on the page No. 8

Only for version with top discharge feature: * Hood with external motor: Over this measurement a hole may be made on the rear section for the passage of the discharge pipe for connection to the external motor. Consult the template for the passage of pipes under this measurement. ** Hood with external motor: Above this measurement a hole may be made on the rear panel for the outward passage of the discharge pipe. Consult the template for the passage of pipes under this measurement. 8 Dimensions a

Summary of the content on the page No. 9

www.zephyronline.com Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS This range hood is designed to exhaust fumes and vapours towards the outside and is ready to be fitted with an internal blower and for discharge towards the top side (Vertical discharge). This range hood can be set for an External Blower and /or to discharge tow

Summary of the content on the page No. 10

Duct pieces Equivalent number Duct pieces Equivalent number lenght x used = Total lenght x used = Total 3 1/4 ” x 10” 1 Ft. x ( ) = Ft. 6" Round 30 Ft. x ( ) = Ft. Rect., wall cap straight with damper 6 ” Round,, 1 Ft. x ( ) = Ft. 6” Round, 30 Ft. x ( ) = Ft. straight roof cap 6” Round to 1 Ft. x ( ) = Ft. 7", 8” 1 Ft. x ( ) = Ft. 3 1/4 ” x 10” Round,, rect. straight transition 3 1/4 ” x 10” 15 Ft. x ( ) = Ft. 6” Round to 16 Ft. x ( ) = Ft. Rect.90° 3 1/4 ” x 10” elbow rect. transition 90° elbo

Summary of the content on the page No. 11

www.zephyronline.com Attention! The installation requires several steps where is asked to temporarily remove some particulars and screws, We recommend to record and keep all of these components in a safe place ready to be used as required. • Remove stainless mesh filters (See relative paragraph on Maintenance section of this manual). • Release the 4 per side threaded knobs and remove the internal left-right side covers. • Unscrew the 4 screws that fix the cover to the Junction box, to access mai

Summary of the content on the page No. 12

Note: for External blower installation disregard the • Install the motor support to the body of the hood instruction in this page and step ahead on page 14. (Rear side) with 4 screws in place of the rear cover previously removed. Note! Lip of motor support must be towards the TOP DISCHARGE inside of the hood in order for screw holes to line (Vertical discharge) up. The hood is ready to be used for vertical discharge, proceed to install the internal blower (See next page). REAR DISCHARGE (Horizon

Summary of the content on the page No. 13

www.zephyronline.com INTERNAL BLOWER INSTALLATION • Fit the blower inside the hood. • Install the blower to the support with 4 screws • Connect the blower to the range hood. (Provided), check that the rectangular outlet of the blower matches with the rectangular slot of the support. Note: The 4 fixing screws must be screwed in from the outside of the hood (See photo below). 13 Installation - Internal Blower

Summary of the content on the page No. 14

Note: for internal blower installation, disregard the • Install the supplied round transition collar to the instruction on this next page and consult the instruction previously installed cover/round transition support on the previous pages (See pages 12-13). plate from inside the hood. Align and attach with 2 Note 2: Refer to the CBE-1000 manual for instructions on screws securely. mounting the external blower to a roof or exterior wall. The manual is available on our website and is included in

Summary of the content on the page No. 15

www.zephyronline.com • Install the external blower junction box with 4 screws. • Install the supplied round transition collar to the previously installed cover/round transition support • Connect the supplied 9 pin male molex plug from the plate. Align and attach with 2 screws securely. external blower wiring to the 9 pin female molex plug on the control board housing. Route wire end through hood and terminate in external blower junction box. See diagram below. EXTERNAL BLOWER ELECTRICAL CONNEC

Summary of the content on the page No. 16

• To attach front panel to hood body, align the 8 threaded studs through the front bodies corresponding holes. Use 8 wing nuts to attach and secure. See diagrams below 4 3 4 1 3 2 2 1 3 6 4 5 5 8 6 7 7 8 x 8 NOTE: The front panel is not supplied with the range hood and must be purchased separately. 16 Installation - Front Panel

Summary of the content on the page No. 17

www.zephyronline.com INSTALLING THE HOOD ONTO THE WALL 1. Disconnect and move freestanding or slide-in range Framing behind drywall from cabinet opening to provide easier access to rear wall. Use a thick, protective covering over countertop, cooktop or range to protect from damage and debris. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it. 2. Mark the centerline on the wall/ceiling where the canopy h

Summary of the content on the page No. 18

13. Optional duct cover installation: Unscrew the 4 screws that fix the section of the Duct Cover (Starting collar) and release all parts. Install the upper section to the support bracket with Support 2 screws. Bracket Note: Check that joined seam is positioned towards the back. Upper Note2: The lower section (Collar) of the duct cover section assembly must be installed at the end of the installation with 2 screws. Lower section (Collar) a. Remove the support bracket from the Duct Cover assembly

Summary of the content on the page No. 19

www.zephyronline.com 14. For internal blower installation ONLY: WARNING a. Horizontal (Rear) discharge: Excessive Weight Hazard - Use three or more people Install from the outside the 3 1/4 ” x 10” Rect. to move and install range hood. Failure to do so can transition on the outlet hole of the blower with 3 result in back or other injury. screws. b. Vertical (Upper) discharge: 16. Secure hood with screws and washers. Install from the outside the 8" plastic round transition, with 4 screws. Install

Summary of the content on the page No. 20

18. Electrical connection 19. Note: disregard this step if the hood has been fitted with an internal blower. WARNING Purchase and install an External blower (See Electrical Shock Hazard paragraph „Before installing the hood - Parts not Warning: Turn off power circuit at the service panel supplied“ for model reference). before wiring this unit. 120 VAC, 15 or 20 Amp circuit required. 20.Check all light bulbs to make sure they are secure in their sockets. ELECTRICAL GROUNDING INSTRUCTIONS THIS APP


Alternative user manuals
# User manual Category Download
1 Zephyr AK11005 User manual Ventilation Hood 2
2 Zephyr AK7500ASX User manual Ventilation Hood 0
3 Zephyr AK7548ASX User manual Ventilation Hood 0
4 Zephyr AK11245 User manual Ventilation Hood 1
5 Zephyr AK8100AS User manual Ventilation Hood 1
6 Zephyr AK11365 User manual Ventilation Hood 0
7 Zephyr AK8100S User manual Ventilation Hood 0
8 Zephyr AK7536ASX User manual Ventilation Hood 1
9 Zephyr AK8000AS User manual Ventilation Hood 1
10 Zephyr AK8200AS User manual Ventilation Hood 2
11 Zephyr AK8300ASX User manual Ventilation Hood 1
12 Zephyr ALL-E42ABX User manual Ventilation Hood 0
13 Zephyr ALL-E42AW X User manual Ventilation Hood 0
14 Zephyr ALL-M90ABX User manual Ventilation Hood 1
15 Zephyr APN-M90ABX User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0