Zephyr COK-E42SX user manual

User manual for the device Zephyr COK-E42SX

Device: Zephyr COK-E42SX
Category: Ventilation Hood
Manufacturer: Zephyr
Size: 0.91 MB
Added : 6/14/2013
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Zephyr COK-E42SX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Zephyr COK-E42SX.

For your convenience

If looking through the Zephyr COK-E42SX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Zephyr COK-E42SX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Zephyr COK-E42SX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Zephyr COK-E42SX User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Zephyr COK-E42SX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Zephyr COK-E42SX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.zephyronline.com
Okeanito
CO K-E36SX
CO K-E42SX
CO K-E48SX
Model number:
Serial number:
Date of Purchase:
Sales Dealer:
©
Zephyr Corporation.
MAY07.0101
Use, Care, and Installation Guide

Summary of the content on the page No. 2

www.zephyronline.com

Summary of the content on the page No. 3

SAFETY NOTICE .............................................. 2 LIST OF MATERIALS ....................................... 3 INSTALLATION Ducting Calculation Sheet ............................... 4 Mounting Height and Clearance ..................... 5 Ducting .................................................................. 6 Specifications ....................................................... 7 Internal Blower .................................................... 8 - 9 Prepar

Summary of the content on the page No. 4

www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE TH E R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT USE TH IS FAN W ITH ANY S O LID-S TATE SPE E D CONTROL DEV IC E. WARNING TO RE DUCE TH E R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO P E R SON S, O B S E RVE TH E FO LLOW ING: a. Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer. b. Before servicing or cleaning unit, switch power off at service panel

Summary of the content on the page No. 5

MODEL:COK-ExxS 1 - Hood 1 - Baffle Filter (2 on 48” model) 2 - 50W 120V Halogen Light Bulbs GU-10 2 - 40W 120V Appliance Bulbs 1 - Utensil Rail 2 - Telescopic Duct Covers 1 - Ceiling Mounting Bracket (pre attached to duct cover) 1 - Wall Mounting Bracket 1-HARDWAREPACKET 7 - 2” Wood Screws 7 - Anchors 7 - 1/2” Washers 4 - 1/2” Screws 5x15mm 4 - 10mm Washers 1 - SMALL HARDWARE PACKET 1 - T ool 3 - Short Set Screws (4 on 48” Model) 1 - HARDWARE PACKET, EXTERNAL BLOWER KIT 1 - 8” Collar 1 - Externa

Summary of the content on the page No. 6

www.zephyronline.com Equivalent number Equivalent number Duct pieces Duct pieces length x used = Total length x used = Total 31/4”x10” 1 Ft. x ( ) = Ft. Ft. 6” Round 30 Ft. x ( ) = Rect., wall cap straight with damper 7” Round, 1 Ft. x ( ) = Ft. 6” Round, 30 Ft. x ( ) = Ft. straight roof cap Ft. 7” Round, 1 Ft. x ( ) = 6” round to 1 Ft. x ( ) = Ft. straight 31/4”x10” rect. transit

Summary of the content on the page No. 7

Minimum mount height between range top to hood bot- tom should be no less than 28". Min 32"-Max 52" Maximum mount height should be no higher than 36". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high 14 1/2" will be hard to reach and will loose its performance and efficiency. Min 96"-Max 124” Min 28"-Max 36" If available, also refer to range manufacturer's height clearance requiremen

Summary of the content on the page No. 8

www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape. Some Ducting Options: External Roof Pitch w/ Blower Flashing & Cap side wall External cap with Blower gravity damper Soffit or crawl space Soffit or crawl

Summary of the content on the page No. 9

15 /32” 1/4” R 4 1/8” O5/16” R 4 11/32” 19 3/4” 10” 19 3/4” 16 5/8” 13 3/8” 14 1/2” LOGO CHENG DESIGN BY ZEPHIR 95° 11 7/8” 36” , 42” , 48” 22 5/8” 5" - 36" 8"- 42" 31/2"-48" 6" 15” 8 5/16” 9 3/16” 7 1“ 7 3/8” Installation - Specifications

Summary of the content on the page No. 10

www.zephyronline.com ATTENTION The following are intructions for installing internal blower model CBI-600. For instructions on preparing for external blower model CBE-1000 please turn to page “10”. Before installing, verify that motor spins freely. The internal blower kit consists of the blower 1. Position blower as shown. and capacitor box with wiring. 2. Att ach blower to flange as shown using 3. P osition capacitor box as shown. the provided 1/2” 5x15mm screws with washers. 4. Secure capacit

Summary of the content on the page No. 11

5. Remove existing grounding screw and 6. Re-attach grounding screw to finish attach grounding wire from capacitor box. installation of capacitor box. Refer to Fig-A on previous page. 7. Attach short capacitor connector to blower 8. Att ach long capacitor connector to control connector. board connector. 9. Use plastic tie to hold wiring together. 10. Remove wood block Final view of internal blower install. Continue to page “12” for hood installation instructions. 9 Installation - Intern

Summary of the content on the page No. 12

www.zephyronline.com ATTENTION The following are intructions on preparing your hood for installation with external blower model CBE-1000. For instructions on installing internal blower model CBI-600 please turn to page “8”. NOTE: Please refer to the CBE-1000 manual for external blower mounting instructions. The external blower kit consists of an 8” 1. Remove screws from internal flange. collar, and external blower wiring box. The external blower is purchased separately. 2. Remove internal flang

Summary of the content on the page No. 13

6. Position cover onto external blower 7. Secure cover to box with provided screw. wiring box. 8. Attach connector from external blower 9. Attach grounding wire from external blower wiring box to control board box connector wiring box to grounding screw of the junction inside hood. box. Refer on Fig-A in diagram below . 10. Final view of external blower preparation Continue to page “12” for hood installation instructions. For external blower installation please refer to the manual included with

Summary of the content on the page No. 14

www.zephyronline.com Duct Cover C/L Ceiling Bracket Duct Cover Ceiling Bracket B 21” C 14 1/2” 7 1/2” A min 28” max 36” C/L Attach screws to C/L ceiling bracket 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2” from line A). This is the top of the hood. 4. Measure up, 7 1/2” from line A and mark mounting spread from C/L Line C. (21”) 5. Follow center line up to the ceiling, measure and mark 6” from the

Summary of the content on the page No. 15

Top gap between bracket and wall B C A Bottom Attach screws to both sides of the duct cove rs and secure to ceiling bracket. 10” Electrical 1. Place wall bracket on line C. Position top of wall bracket so it is even with the 21” mounting spread. Make sure bracket is attached to wall as shown in the diagram. The top of the wall bracket should have a gap between it and the wall. The bottomshould be flush against the wall. Use (3) 2” wood screws to attach bracket to wall. Use anchors if not mountin

Summary of the content on the page No. 16

www.zephyronline.com Set screw Front Back 1. Attach utensil rail to hood canopy. A small hole has been pre-drilled into the canopy to provide a starting point to attach the first utensil rail post. After the first post is lined up with the hole, gently slide the rest of the rail onto the canopy. (note: be careful not to scratch the stainless steel when performing this step, this is why there is a starter hole). 2. Attach a short set screw into eac h post in order to hold utensil rail onto canopy

Summary of the content on the page No. 17

5 www.zephyronline.com 1 Blower On/Off Display (Speed level, Delay Off Indicator, Filter Clean/Change) 2 6 Adjust 3 Speed Levels Mood Light On/Off 4 Lights On/Off/Hold to Dim 3 15 Min Delay Off 1. Blower On/Off By pressing , the blower is switched On and Off. 2. Speed Selection The 3 speed levels are selected by pressing to decrease and to increase speed level. The display indicates level selected. 3. Delay Off This is used for programmed shut down of blower and lights 15 m

Summary of the content on the page No. 18

FilterCleanReminder(StandardBaffleFiltersfitted): A set of baffle filters are fitted by the factory. These Baffle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The FilterCleanReminder function in the microprocessor will automatically indicate by a flashing when the metal filters need to be cleaned after every 30 hrs. of use. Filters can be cleaned by hand with non-abrasive soap or in a dishwashe

Summary of the content on the page No. 19

www.zephyronline.com Surface Maintenance: Clean periodicallywithhot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads whi i ich will scratch and damage surface. For heavier soil use liquiddegreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, topolish and buff out the stainless luster and grain. Always scrub lightly y y with clean cotton cloth, and with the grain. Do not use any product containing chlorine

Summary of the content on the page No. 20

Replacing Light Bulbs: CAUTION: Light bulbs become extremelyhotwhen turnedon. DO NOT touch bulbs untilswitched off and cooled. Touching hotbulbs may cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the light socket will now protude from the hood allowing you to remove the bulb.(Be careful when releasing retain clip as it is under pressure to hold it in place) Replacement halogen bulbs are availab


Alternative user manuals
# User manual Category Download
1 Zephyr AK11005 User manual Ventilation Hood 2
2 Zephyr AK7500ASX User manual Ventilation Hood 0
3 Zephyr AK7548ASX User manual Ventilation Hood 0
4 Zephyr AK11245 User manual Ventilation Hood 1
5 Zephyr AK8100AS User manual Ventilation Hood 1
6 Zephyr AK11365 User manual Ventilation Hood 0
7 Zephyr AK8100S User manual Ventilation Hood 0
8 Zephyr AK7536ASX User manual Ventilation Hood 1
9 Zephyr AK8000AS User manual Ventilation Hood 1
10 Zephyr AK8200AS User manual Ventilation Hood 2
11 Zephyr AK8300ASX User manual Ventilation Hood 1
12 Zephyr ALL-E42ABX User manual Ventilation Hood 0
13 Zephyr ALL-E42AW X User manual Ventilation Hood 0
14 Zephyr ALL-M90ABX User manual Ventilation Hood 1
15 Zephyr APN-M90ABX User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0