Zephyr ATI-M90ABX user manual

User manual for the device Zephyr ATI-M90ABX

Device: Zephyr ATI-M90ABX
Category: Ventilation Hood
Manufacturer: Zephyr
Size: 2.16 MB
Added : 6/14/2013
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Zephyr ATI-M90ABX. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Zephyr ATI-M90ABX.

For your convenience

If looking through the Zephyr ATI-M90ABX user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Zephyr ATI-M90ABX on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Zephyr ATI-M90ABX to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Zephyr ATI-M90ABX User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Zephyr ATI-M90ABX but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Zephyr ATI-M90ABX. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.zephyronline.com
Tilt
ATI-M90ASX
ATI-M90ABX
RANGE HOOD - Installation instructions

Summary of the content on the page No. 2

www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 23 CAMPANA EXTRACTORA - Manual de utilización...Pag. 45 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 67 - 2 -

Summary of the content on the page No. 3

SAFETY INSTRUCTIONS..................................................................................................pag. 4 LIST OF MATERIALS...........................................................................................................pag. 7 DUCTING CALCULATION SHEETS...............................................................................pag. 8 HOOD SPECIFICATION.....................................................................................................pag. 9 INSTALL

Summary of the content on the page No. 4

www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents. Suitable for use in household cooking area WARNING - To reduce the

Summary of the content on the page No. 5

settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, fi lters and grease laden surface clean. F. Use high range setting on range only when necessary.Heat oil slowly on low to medium settin

Summary of the content on the page No. 6

www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducte

Summary of the content on the page No. 7

Top Cover Front Panel Electrical Junction Box Control Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 1/4" x 2-3/4" 6 D - 7 - List of Materials

Summary of the content on the page No. 8

www.zephyronline.com Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 8 - Ducting Calculation Sheet

Summary of the content on the page No. 9

front of hood side of hood top of hood - 9 - Hood Specifi cations

Summary of the content on the page No. 10

www.zephyronline.com NOTE! The device in this version (with internal suction motor) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by following the steps indicated in the following paragraphs; upon reaching step 7, the motor plate must not be rotated, there- fore skip steps 8 and 9 and proceed from step 10 directly. The following instructions are for installing the internal b

Summary of the content on the page No. 11

6. Remove the 6” round metal knockout pla- te from the blower plate by using a fl at head screwdriver. See. Fig.4 7. Remove the (10 ) screws securing the blo- wer plate to the blower housing and remo- ve blower plate. See. Fig.5 (Note! If air is discharged from the top, do not rotate the plate; proceed from step 10 in- stead). 8. Remove the rectangular plate and the fi - xing bracket from the motor plate by loo- sening the 6 screws. Fig.6 9. Rotate the motor plate by 90° and fi x the rectang

Summary of the content on the page No. 12

www.zephyronline.com 13. Secure Green/Yellow ground wire connected to the cable to the provided capacitor to blower plate. (type A) Fig. 11 14. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing. See Fig.12 15. Install the blower and plate on the inside of the blower housing: carry out the instruc- tions at step 3 in re- verse order then use the screws provided to complete installa- tion.(Tot. 16 type B) Fig.13 1

Summary of the content on the page No. 13

NOTE! The device in this version (with external motor) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the follow- ing paragraphs; upon reaching step 7, the motor plate must be rotated and installed in the opposite direction. The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1

Summary of the content on the page No. 14

www.zephyronline.com 5. Close the front panel while holding it by its external sides until it shuts. 6. Remove the metal motor plate by striking it with the aid of a slotted screwdriver. Fig. 4 7 . Remove the (10) screws securing the blo- wer plate to the blower housing and re- move blower plate. See Fig.5 8. (if air is discharged from the top, rotate the motor plate by 90° and fi x the rectan- gular plate and the fi xing bracket in the opposite direction.) Install the chosen flange: rec

Summary of the content on the page No. 15

Note: Carry out the power supplly con- nection in accordance with the national electric code, ANSI/NFPA 70-1999. Note1: A cable lock (not included) may be required by local codes. Please review lo- cal codes for more information. 12. Attach 6 pin male molex connectors to 6 pin female molex connectors inside blo- wer housing. See Fig 11 Note2: Check local codes to determine mi- nimum wire gauge. See manual included with external and in-line blower for instructions on installing the blowe -

Summary of the content on the page No. 16

www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certif ed Silver Tape or Duct Tape. Some Ducting Options - 16 - Installation - Ducting Options

Summary of the content on the page No. 17

MOUNTING HEIGHTS The range hood must be installed at a minimum height of 22 inches (56 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot    air or fumes from another appliance. Before pro- ceeding with the assembly instructions remove the decorative mesh fi lters so that the range hood is  esier to handle.

Summary of the content on the page No. 18

www.zephyronline.com WARNING: In order to facilitate their connection, make sure that the power supply conduits are not obstructed by the hood. 3. When the hood has been adjusted tighten the screws to secure the hood in place. 4. Once the adjustment has been completed, fi x the hood defi nitely using another (2 type D) screws. NOTE: Screws must be fastened into wooden studs so wood blocking may be necessary. If using wall anchors make sure to check your local codes for suita- bility and typ

Summary of the content on the page No. 19

GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Remove the power supply cover by undoing the (2) screws Fig. 17. 2. Break through the hole on the box. 3. Pass the wires through the hole in the box and fasten the power supply conduit. Fig.18 4. Connect the wires of the hood to tho

Summary of the content on the page No. 20

www.zephyronline.com MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance. • The decorative mesh fi lters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use. In order to p


Alternative user manuals
# User manual Category Download
1 Zephyr AK11005 User manual Ventilation Hood 2
2 Zephyr AK7500ASX User manual Ventilation Hood 0
3 Zephyr AK7548ASX User manual Ventilation Hood 0
4 Zephyr AK11245 User manual Ventilation Hood 1
5 Zephyr AK8100AS User manual Ventilation Hood 1
6 Zephyr AK11365 User manual Ventilation Hood 0
7 Zephyr AK8100S User manual Ventilation Hood 0
8 Zephyr AK7536ASX User manual Ventilation Hood 1
9 Zephyr AK8000AS User manual Ventilation Hood 1
10 Zephyr AK8200AS User manual Ventilation Hood 2
11 Zephyr AK8300ASX User manual Ventilation Hood 1
12 Zephyr ALL-E42ABX User manual Ventilation Hood 0
13 Zephyr ALL-E42AW X User manual Ventilation Hood 0
14 Zephyr ALL-M90ABX User manual Ventilation Hood 1
15 Zephyr APN-M90ABX User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0