Wells VENTLESS HOOD WVSW user manual

User manual for the device Wells VENTLESS HOOD WVSW

Device: Wells VENTLESS HOOD WVSW
Category: Ventilation Hood
Manufacturer: Wells
Size: 0.55 MB
Added : 3/6/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Wells VENTLESS HOOD WVSW. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Wells VENTLESS HOOD WVSW.

For your convenience

If looking through the Wells VENTLESS HOOD WVSW user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Wells VENTLESS HOOD WVSW on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Wells VENTLESS HOOD WVSW to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Wells VENTLESS HOOD WVSW User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Wells VENTLESS HOOD WVSW but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Wells VENTLESS HOOD WVSW. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

531
OWNERS MANUAL

MODEL
WVSW
VENTLESS
HOOD
For
CONVEYOR
WARMERS



Includes
INSTALLATION
USE & CARE
SERVICE
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.

THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APP

Summary of the content on the page No. 2

LIMITED WARRANTY STATEMENT Unless otherwise specified, all commercial cooking equip- thorized personnel. The prices charged by Wells Mfg. Co. ment manufactured by WELLS MFG. CO. is warranted for its products are based upon the limitations in this war- against defects in materials and workmanship for a period of ranty. Seller’s obligation under this warranty is limited to the one year from the date of original installation or 18 months repair of defects without charge by a Wells Mfg. Co. fact

Summary of the content on the page No. 3

TABLE OF CONTENTS WARRANTY xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 AGENCY LISTING INFORMATION 3 PRECAUTIONS & GENERAL INFORMATION 4 INSTALLATION 5 OPERATION

Summary of the content on the page No. 4

FEATURES & OPERATING CONTROLS WVSW VENTLESS HOOD Fig. 1 Features & Operating Controls 2

Summary of the content on the page No. 5

FEATURES & OPERATING CONTROLS (continued) ITEM DESCRIPTION CANOPY Removable canopies aid in vapor capture at entry and exit of the conveyor warmer. Canopies hang from mounting pins at each end of the hood. ELECTRICAL The hood plugs into a NEMA 5-15R (120V) or 6-15R (208/240V) receptacle with a 6' power cord. An illuminated power switch on the front panel is used to start/stop the hood fan. EXHAUST The hood uses an exhaust fan to provide air movement. The fan exhausts through a screen

Summary of the content on the page No. 6

PRECAUTIONS AND GENERAL INFORMATION This appliance is intended for use in commercial establishments WARNING: only. Electric Shock hazard This appliance is intended as a smoke and odor control device, designed for use with specified warming equipment. No other use is All servicing requiring recommended or authorized by the manufacturer or its agents. access to non-insulated Operators of this appliance must be familiar with the appliance use, electrical components limitation

Summary of the content on the page No. 7

INSTALLATION UNPACKING & INSPECTION NOTE: DO NOT discard the carton or other packing Carefully read all instructions in this manual before starting any materials until you have installation. inspected the hood for hidden Carefully remove the hood from the carton. damage and tested it for proper operation. IMPORTANT: Appliance weighs 92 lbs (42.7 kg). Use appropriate Refer to SHIPPING DAMAGE care when removing from carton and installing on conveyor warmer. CLAIM PROCEDURE o

Summary of the content on the page No. 8

INSTALLATION (continued) ELECTRICAL INSTALLATION WARNING! Electric Refer to the nameplate. Verify the electrical power source. Voltage Shock hazard and phase must match the nameplate specifications. Plugging the All servicing requiring hood into the wrong voltage can severely damage the unit . access to non-insulated Your hood is equipped with a grounded electrical cord. This cord electrical components must be plugged into a properly grounded NEMA 5-15R (120V) or must be p

Summary of the content on the page No. 9

OPERATION OPERATING CONTROLS Controls include a lighted POWER SWITCH and an amber REPLACE FILTER indicator light. Press POWER SWITCH to ON anytime conveyor warmer is operating. When power is first turned on, the REPLACE FILTER light will glow. As the fan comes up to speed and air flow is established, the REPLACE FILTER light will go out. If the REPLACE FILTER light does not go out, the filters must be replaced. However, the fan will continue to operate when the

Summary of the content on the page No. 10

CLEANING INSTRUCTIONS CAUTION! PREPARATION Unplug hood and conveyor warmer Allow to cool completely before cleaning Personal Injury Hazard FREQUENCY Daily Disconnect power from hood TOOLS Mild Detergent and conveyor warmer before Soft Cloth or Sponge cleaning. 1. Disconnect power from hood and conveyor warmer before cleaning. IMPORTANT: DO NOT spill or po

Summary of the content on the page No. 11

TROUBLESHOOTING SUGGESTIONS SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Plug cord into appropriate power No operation, no lights Cord unplugged receptacle. Circuit breaker off or tripped Reset circuit breaker Damaged power cord or plug Replace power cord Damaged power switch Replace power switch REPLACE FILTER light remains Filters dirty Replace filters lit (never shuts off) If filters are clean New filter still in plastic wrapper Remove plastic wrapper and fan is operating Clear

Summary of the content on the page No. 12

SERVICE INSRTUCTIONS IMPORTANT: VACUUM DIAGRAM DO NOT store anything on top of the hood. DO NOT block the exhaust opening. Filter operation is monitored by a vacuum switch and a system of vacuum hoses. The switch energizes the REPLACE FILTER light if airflow through the filters is insufficient for efficient operation. The light is a warning only, and does not control the operation of the hood. 10

Summary of the content on the page No. 13

PARTS & SERVICE DESCRIPTION PART NO. IMPORTANT: Use only factory authorized service HIGH EFFICIENCY FILTER 16 x 20x 4 22862 parts and replacement filters. CHARCOAL (CARBON) FILTER 14 x 20 x 7/8 22403 For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Manufacturing Co. 2 Erik Circle P. O. Box 280 Verdi,

Summary of the content on the page No. 14


Alternative user manuals
# User manual Category Download
1 Wells WVF-886 User manual Ventilation Hood 0
2 Wells WVSW VENTLESS HOOD User manual Ventilation Hood 0
3 Sony SH-L35W User manual Ventilation Hood 0
4 Air King AIF8X User manual Ventilation Hood 3
5 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
6 Air King AIF10X User manual Ventilation Hood 0
7 Agilent Technologies 31A User manual Ventilation Hood 0
8 Air King 500CFM User manual Ventilation Hood 0
9 Agilent Technologies 6610XA User manual Ventilation Hood 1
10 Air King AIK14X User manual Ventilation Hood 0
11 Agilent Technologies HP 83621A User manual Ventilation Hood 0
12 Air King 380 CFM User manual Ventilation Hood 38
13 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2
14 Air King AD series User manual Ventilation Hood 1
15 AEG DD 8665 User manual Ventilation Hood 4