Trane VUV 1500 CFM user manual

User manual for the device Trane VUV 1500 CFM

Device: Trane VUV 1500 CFM
Category: Ventilation Hood
Manufacturer: Trane
Size: 1.86 MB
Added : 10/8/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane VUV 1500 CFM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane VUV 1500 CFM.

For your convenience

If looking through the Trane VUV 1500 CFM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane VUV 1500 CFM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane VUV 1500 CFM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane VUV 1500 CFM User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane VUV 1500 CFM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane VUV 1500 CFM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
Owner
Maintenance
Vertical Unit Ventilator
Classroom Unit Ventilator
Model VUV
Models
“A” and later Design Sequence
VUVE
750 CFM – 1500 CFM
October 2007 UV-SVN03D-EN

Summary of the content on the page No. 2

Notice NOTICE: Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully. WARNING – Indicates a potentially hazardous situation ! which, if not avoided, could result in death or serious injury. ! CAUTION – Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION – Indicates a situation that may result in equipment or property-damage-only a

Summary of the content on the page No. 3

Contents Installation/Startup/Commissioning 4 Pre-installation Checklist 4 5 General Information 7 Dimensions/Weights 14 Installation Instructions 24 Electrical Requirements 26 Pre-Startup Checklist 27 Maintenance 30 Warranty Information 31 Troubleshooting Checklist 33 Unit Wiring UV-SVN03D-EN 3

Summary of the content on the page No. 4

Pre-installation Checklist Jobsite Inspection Always perform the following checks before accepting a unit: 1. Verify that the nameplate data matches the data on the sales order and bill of lading (including electrical data). 2. Verify that the power supply complies with the unit nameplate specifications. 3. Visually inspect the exterior of the unit, for signs of shipping damage. Do not sign the bill of lading accepting the unit(s) until inspection has been com- pleted. Check for damage prompt

Summary of the content on the page No. 5

General Information Unit Nameplate nance (oiling is not needed), and/or The unit nameplate is located in the bearing replacement. left hand end pocket, behind the con- Filters trol box. It includes the unit model Filter sizing for the unit ventilator are number, serial number, electrical char- an off-the-shelf design to reduce or acteristics, and other pertinent unit da- help eliminate local stocking of the fil- ta. ters. Factory Shipment Sliding Fan Deck Before shipment, each unit is leak

Summary of the content on the page No. 6

General Information OA/RA Actuator (Option) Table 1: OA/RA actuator specification Table 2: Face-bypass actuator specification The OA/RA actuator provides true spring return operation for positive close-off of the OA/RA damper. The spring return system of the actuator closes the outside damper if power is Power Supply 24 VAC ± 20% 50/60 HZ lost to the building. When ordered Power Supply 24 VAC ± 20% 50/60 HZ with factory controls, the actuator is a 24 VAC ± 10% 3-point floating design.

Summary of the content on the page No. 7

Dimensions/Weights/ Clearance ! WARNING Improper Unit Lift! Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result in death or serious injury or possible equipment or property-only damage. Table G1: VUVE general data Description Unit Size 0750 1000 1250 1500 Unit Length w/o end covers (inches) 69 81 93 105 Unit Depth - Standard (inches) 16 5/8

Summary of the content on the page No. 8

Dimensions Standard Depth Unit 8 UV-SVN03D-EN

Summary of the content on the page No. 9

Dimensions Falseback Unit UV-SVN03D-EN 9

Summary of the content on the page No. 10

Dimensions Dynamic Air Barrier Unit 10 UV-SVN03D-EN

Summary of the content on the page No. 11

Dimensions End Covers UV-SVN03D-EN 11

Summary of the content on the page No. 12

Dimensions Wall Boxes 12 UV-SVN03D-EN

Summary of the content on the page No. 13

Dimensions Crossover Piping 16 5/8" DEPTH UNIT 7/8" I.D. FIELD CONN. W/ SHUT 1 1/2" FLUSH RETURN OFF VALVE 3" S R SUPPLY 3 1/2" 24" 4 1/2" 19 3/8" TOP VIEW 3 5/8" 5 3/8" SIDE VIEW 21 1/4" DEPTH UNIT 7/8" I.D. FIELD 1 1/4" CONN. W/ SHUT FLUSH RETURN OFF VALVE 3" SUPPLY S R 24" 19 3/8" 3 1/2" 4 1/2" TOP VIEW 8 1/4" 10" SIDE VIEW Notes: 1-3/8" o.d. and 2-1/8" o.d. crossover piping 1 Crossover piping is available for all 2 or 4-pipe coils selections. Trane pro- vides the crossover for the cold water

Summary of the content on the page No. 14

Installation Interior Wall Wall Box Installation Installation in Masonry Walls w/ sheetrock The following instructions are general A typical method of installing the wall recommendations for installing wall box in a masonry wall opening is Outside Unit intake boxes. Consult the architectural shown in Figure 1. Wall plans for specific requirements. Grout the top and bottom of the wall Additional materials required to com- box frame as noted. A sloped water plete any specific installations

Summary of the content on the page No. 15

Installation General Installation Checks Location Considerations 5 Internal access to the unit is pro- The checklist below is a summary of Selecting the appropriate location for vided by the removable front pan- the steps required to successfully in- installing a unit is very important. The el. Sufficient space should be stall a unit. This checklist is intended to following factors should be consid- allowed to lift the panel for mainte- acquaint the installing personnel with ered: nance purpo

Summary of the content on the page No. 16

Installation Figure 3: Mounting hole location F E C C B B A D AB C D E F Standard Unit (no Falseback) 1.31 13.50 2.75 66.39 10.38 45.64 075 Standard falseback 1.00 2.13 26.00 67.00 10.00 47.00 29" stepdown falseback 1.00 2.13 24.44 67.00 10.00 47.00 28" stepdown falseback 1.00 2.13 23.44 67.00 10.00 47.00 27" stepdown falseback 1.00 2.13 22.44 67.00 10.00 47.00 26" stepdown falseback 1.00 2.13 21.44 67.00 10.00 47.00 25" stepdown falseback 1.00 2.13 20.44 67.00 10.00 47.00 100 Standard Unit (n

Summary of the content on the page No. 17

Installation Unit Mounting rather than the holes located in the End Panels Note: All wall intake boxes should be unit’s end pockets. When ordered as an option, end cov- installed prior to mounting the unit ers ship already attached to the verti- ventilator. Refer to Page 14 for wall Note: Ensure the unit is level. Coils cal unit ventilator. The following box installation instructions. and drain pans inside the unit are section is for installing end covers pur- pitched properly for draining b

Summary of the content on the page No. 18

Installation Piping Installation 7 After the condensate drain piping Installation Crossover Piping Before installation of piping package, has been completed, check water Crossover piping is available for all hy- the shipping bracket holding the pip- flow to ensure the system proper- dronic coils. It is either 1 3/8’’ \[34.9\] or ing in place, must be removed. ly carries and away all condensate 2 1/8’’ \[54\] in diameter (O.D.) as spec- accumulation. ified by the customer. Crossover pip- Proper

Summary of the content on the page No. 19

Installation Split System Units Steam Piping The following refrigerant piping and When air, water or another product is interconnecting wiring instructions heated, the temperature or heat trans- apply to unit ventilators with direct ex- fer rate can be regulated by a modulat- pansion type cooling coils used in con- ing steam pressure control valve. junction with air-cooled condensing Since pressure and temperature do units. Reference must also be made to not vary at the same rate as load, th

Summary of the content on the page No. 20

Installation Figure 6b: Steam piping Modulating Water Valves (Option) Use the following steps to complete The actuator on the valve is a 24V, 3- cartridge assembly removal: Closed point floating valve. The actuator can 1 Remove valve actuator. be easily removed from the valve body B 2 Remove the cartridge assembly by pressing in on the locking tab and A from the valve body with the en- rotating the actuator 45° counter- closed tool. clockwise (See Figure 6a). The 2-way 3 Solder the valve i


Alternative user manuals
# User manual Category Download
1 Trane Tracer Unit Ventilator User manual Ventilation Hood 1
2 Trane ZN.520 User manual Ventilation Hood 5
3 Trane YCZ035F1 User manual Ventilation Hood 0
4 Trane VUV 750 CFM User manual Ventilation Hood 1
5 Trane YCZ036F1/3M0B User manual Ventilation Hood 0
6 Sony SH-L35W User manual Ventilation Hood 0
7 Air King AIF8X User manual Ventilation Hood 3
8 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
9 Air King AIF10X User manual Ventilation Hood 0
10 Agilent Technologies 31A User manual Ventilation Hood 0
11 Air King 500CFM User manual Ventilation Hood 0
12 Agilent Technologies 6610XA User manual Ventilation Hood 1
13 Air King AIK14X User manual Ventilation Hood 0
14 Agilent Technologies HP 83621A User manual Ventilation Hood 0
15 Air King 380 CFM User manual Ventilation Hood 38