Tradewins Furniture RNC5-TPD user manual

User manual for the device Tradewins Furniture RNC5-TPD

Device: Tradewins Furniture RNC5-TPD
Category: Ventilation Hood
Manufacturer: Tradewins Furniture
Size: 1.77 MB
Added : 10/8/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tradewins Furniture RNC5-TPD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tradewins Furniture RNC5-TPD.

For your convenience

If looking through the Tradewins Furniture RNC5-TPD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tradewins Furniture RNC5-TPD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tradewins Furniture RNC5-TPD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tradewins Furniture RNC5-TPD User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tradewins Furniture RNC5-TPD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tradewins Furniture RNC5-TPD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODELS RNC5-TPD, RNC5-TPF
TM
HEA HEAT RECO T RECOVER VERY Y VENTILA VENTILAT TO OR R
INSTALLATION INSTRUCTIONS
Shipping and Packing List Application
Heat Recovery Ventilators (HRV) are designed to pro-
Package 1 of 1 contains:
vide fresh air while exhausting an equal amount of stale
1 - Assembled ventilator
air.
1 - Bag assembly containing:
1 - Drain spout assembly (HRV units only)
The HRV is equipped with an aluminum core. The
device uses the stale air that is being exhausted to con-
4 - Hangin

Summary of the content on the page No. 2

Engineering Data Model RNC5-TPD TM Performance (H.V.I. certified) Net supply air flow in cfm (L/s) against external static pressure HEA HEAT T RECO RECOVER VERY Y VENTILA VENTILAT TO OR R E.S.P (external static pressure) [cfm (L/s)] THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE @ 0.1" (25 Pa) 169 (80) The cross-flow heat recovery core transfers heat between the two airstreams. @ 0.2" (50 Pa) 156 (73) @ 0.3" (75 Pa) 149 (70) It is easily removed for cleaning or service. @ 0.4" (100 Pa) 136 (64) M

Summary of the content on the page No. 3

Engineering Data Model RNC5-TPF TM Performance Net supply air flow in cfm (L/s) against external static pressure E.S.P H HEA EAT T RECO RECOVER VERY Y VENTILA VENTILAT TO OR R (external static pressure) [cfm (L/s)] @ 0.1" (25 Pa) 169 (80) THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE @ 0.2" (50 Pa) 156 (73) The cross-flow heat recovery core transfers heat between the two airstreams. It @ 0.3" (75 Pa) 149 (70) is easily removed for cleaning or service. @ 0.4" (100 Pa) 136 (64) @ 0.5" (125 Pa) 126

Summary of the content on the page No. 4

Clearances and Requirements Connecting Appliances to the HRV The following appliances should not be connected to the WARNING HRV: Before installation, careful consideration must • clothes dryer be given to how this system will operate if connected to any other piece of mechanical • range top equipment, i.e. a forced air furnace or air handler, • stovetop fan operating at a higher static. After installation, the • central vacuum system compatibility of the two pieces of equipment must be confirme

Summary of the content on the page No. 5

Installation Suspending the Unit using the Provided Hanging Straps CAUTION Unit must be installed level to ensure proper condensate drainage. Due to the broad range of installation and operational conditions, consideration must be given for the possibility Wide Head Nails WIDE HEAD (not supplied) of condensation forming on the unit or NAILS (not supplied) connecting ducting. Objects below the STRAPS installation may be exposed to condensate. AND SCREWS (supplied) • At least 3' (1 m)

Summary of the content on the page No. 6

Air Duct Design and Installation A well designed and installed ducting system will allow the WARNING HRV to operate at its maximum efficiency. Always try to keep duct runs as short and straight as pos- Include a short length of fabric, flex duct or other non-metallic connector in the “Fresh Air to sible. See Installation Diagrams for various installation Building” hard ducted line in order to keep the options. HRV separately grounded (electrically) from the The inner and outer liners of the

Summary of the content on the page No. 7

Stale Air Exhaust System Drain Connection (HRV Only) The stale air exhaust system draws air from the points in During a defrost cycle, the HRV may produce some con- the house where the worst air quality problems occur. densation. This water should flow into a nearby drain, or Stale air ducts should be installed in the bathroom, be taken away by a condensate pump. kitchen, and laundry room. Applications such as green- houses, atriums, swimming pools, saunas, etc. have CAUTION unique ventilation r

Summary of the content on the page No. 8

Application Illustrations Partially Dedicated System for HRV ● Staleairdrawnfromkeyareasof home(bathroom,kitchen,laundry) WARNING HRVmustbebalanced. ● Freshairsuppliedtoreturn airductofairhandler DIRECTCONNECTIONoftheSUPPLYAIRSTREAMtotheAIRHANDLERCOLDAIRRETURN (Staleairdrawnfromkeyareasofhome) STALEAIRfromvariouspartsofhome. i.e.bathrooms(ifrequired),kitchens(ifrequired). Outdoors StaleAirToOutside ReturnAir 3'min. recommended FreshAir

Summary of the content on the page No. 9

Application Illustrations Simplified Installation for HRV (Return/Return Method) ● It is mandatory that the air handler blower WARNING run continuously or HRV operation be interlocked with the air handler blower. HRV must be balanced. ● Check local codes/authority having jurisdiction for acceptance. DIRECT CONNECTION of both the HRV SUPPLY AIR STREAM and EXHAUST AIR STREAM to the AIR HANDLER COLD AIR RETURN *Unit is normally balanced on Return Air HIGH speed with air handler 40" (1m) M

Summary of the content on the page No. 10

Application Illustrations Fully Dedicated System for HRV ● Staleairdrawnfromkeyareasof home(bathroom,kitchen,laundry) WARNING HRVmustbebalanced. ● Freshairsuppliedtomainliving areasofhouse STALEAIRfromvariouspartsofhome. i.e.bathrooms(ifrequired),kitchens(ifrequired). Outdoors StaleAirToOutside FreshAirToBuilding FreshAirFromOutside *UnitisnormallybalancedonHIGHspeed withairhandlerblowerON. NOTES: 1.Weatherhoodarrangementisfordrawingpu

Summary of the content on the page No. 11

Electrical The HRV unit should be plugged into a standard designat- ed (120VAC) electrical outlet with a ground. The outlet WARNING should be serviced by a separate 15 amp/120V circuit. An In order to prevent electric shock when cleaning extension cord should not be used with this appliance. A or servicing the HRV, it is extremely important to qualified service technician should make any required confirm the polarity of the power line that is electrical connections. switched by the safety (di

Summary of the content on the page No. 12

Remote Control Devices Optional Main Controls The Dehumidstat Dial The amount of ventilation required in your home will fluctu- Main controls feature a dehumidistat dial. The dehumidistat ate according to the activity level in the house. Higher activity is used to reduce high winter humidity levels. The dehumidis- levels require more ventilation. tat activates high speed ventilation when the indoor humidity level exceeds selected setting. Main controls can be mounted in a central location of the

Summary of the content on the page No. 13

Wiring the Controls 2040 ON/OFF Dehumidistat Ventilation Dehumidistat Control (DVC) Remove Remove Red to Red Red to Red factory installed factory installed jumper when jumper when Orange to Orange to installing this Orange installing this Orange control* control* Black to Black Black to Black Low Fan to Blue Circuit Board Circuit Board Terminal Strip** Terminal Strip** Recirculation Control Remote Dehumidistat Red to Red Red to Red Remove factory Factory Orange to installed jumper Oran

Summary of the content on the page No. 14

Operation For most installations the HRV will normally be set to oper- Self Test ate continuously on low speed. To suit various lifestyles, The ventilator will automatically initiate a self test the HRV offers a selection of operating modes (See sequence when power is applied. Fan motor is cycled and "Operation Mode Selection" on this page). then damper motor is cycled. (RNC5-TPD only) Duration: Approximately 1.5 mins. Method of Operation Good - intermittent operation at all times How much venti

Summary of the content on the page No. 15

Wiring Diagrams Model RNC5-TPD RED BLUE TO MOTORS INTERFACE RELAY CONTACTS DEFROST DETAILS Model RNC5 (Only) PCB PLUG - IN 12 P1 PLUG IN CONNECTOR 3 4 BLACK BLACK ORANGE ORANGE PIN 1 - RED RED RED PIN 2 - ORANGE PIN 3 - BLACK BI-DIRECTIONAL PIN 4 - SPARE DAMPER MOTOR 15

Summary of the content on the page No. 16

Wiring Diagrams Model RNC5-TPF LOW SPEED RED BLUE WHITE BLACK TO TO EXHAUST SUPPLY MOTOR MOTOR 16 BROWN

Summary of the content on the page No. 17

Interlocking HRV Operation to an Airhandler/Furnace Blower When using the Interface relay contacts to initiate blower operation on a fur- nace, certain thermostats will initiate the outdoor cooling condenser when R and G are closed. Use this wiring configuration to prevent the Interface relay contacts from initializing the condenser unit. This problem can occur at the thermostat because the Y terminal is connected to the G terminal internal to the stat. When R and G are closed at the furnace (by

Summary of the content on the page No. 18

Defrost Operation Damper Defrost Fan Defrost MODEL RNC5-TPD MODEL RNC5-TPF The damper defrost HRV has an electronically controlled The fan defrost HRV is equipped with an electronically damper defrost mechanism. The defrost timer is activated controlled fan defrost system to remove frost that collects when the outside temperature drops below 27°F (-3°C). A on the warm air side of the aluminum heat transfer sur- motor driven damper door mechanism closes off the sup- faces of the heat exchanger co

Summary of the content on the page No. 19

Air Flow Balancing It is necessary to have balanced air flow in an HRV. The vol- The first step is to operate all mechanical systems on high ume of air brought in from the outside must equal the volume speed, which have an influence on the ventilation system, i.e. of air exhausted by the unit. If the air flow is not properly bal- the HRV itself and the air handler, if applicable. This will pro- anced, then: vide the maximum pressure that the HRV will need to overcome, and allow for a more accura

Summary of the content on the page No. 20

Pitot Tube and Gauge Pitot Tube Air Flow Balancing Kit with magnehelic gauge, DUCT Pitot tube, hose and carry case. AIR FLOW Pitot tube Magnehelic gauge High Pressure Side Low Pressure Side Placement of Pitot Tube HRV NOTE: Graphic is for illustrative purposes only. Duct connection ports may vary. STALE AIR from various parts of home. i.e. bathrooms (if required), kitchens (if required). Stale Air To Outside Fresh Air From Outside 20 MAGNEHELIC MAGNEHELIC MAGNEHELIC


Alternative user manuals
# User manual Category Download
1 Tradewins Furniture RNC15 User manual Ventilation Hood 0
2 Tradewins Furniture RNC10 User manual Ventilation Hood 0
3 Tradewins Furniture RNC5-TPF User manual Ventilation Hood 0
4 Tradewins Furniture RNC95 User manual Ventilation Hood 0
5 Tradewins Furniture RNC25 User manual Ventilation Hood 0
6 Tradewins Furniture RNC20 User manual Ventilation Hood 0
7 Sony SH-L35W User manual Ventilation Hood 0
8 Air King AIF8X User manual Ventilation Hood 3
9 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
10 Air King AIF10X User manual Ventilation Hood 0
11 Agilent Technologies 31A User manual Ventilation Hood 0
12 Air King 500CFM User manual Ventilation Hood 0
13 Agilent Technologies 6610XA User manual Ventilation Hood 1
14 Air King AIK14X User manual Ventilation Hood 0
15 Agilent Technologies HP 83621A User manual Ventilation Hood 0