Smeg KSE912XU user manual

User manual for the device Smeg KSE912XU

Device: Smeg KSE912XU
Category: Ventilation Hood
Manufacturer: Smeg
Size: 0.23 MB
Added : 10/23/2014
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Smeg KSE912XU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Smeg KSE912XU.

For your convenience

If looking through the Smeg KSE912XU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Smeg KSE912XU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Smeg KSE912XU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Smeg KSE912XU User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Smeg KSE912XU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Smeg KSE912XU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Manuel d’Instructions
Instructions Manual
Manual de instrucciones
KSE912XU

Summary of the content on the page No. 2

INDEX WARNINGS AND REQUIREMENTS .....................................................................................................................................3 RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................6 DIMENSIONS and MAIN PARTS...........................................................................................................................................7 INSTALLATION

Summary of the content on the page No. 3

READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local electrical inspec- tors’ use. READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Alw

Summary of the content on the page No. 4

W A R N I N G � Venting system MUST lead the air outside the building. � DO NOT expel the air through a ductwork in an attic or other enclosed space. � DO NOT use 4" laundry-type wall caps. � Flexible-type ductwork is NOT recommended. � DO NOT obstruct the flow of combustion and ventilation air. � Failure to follow venting requirements may result in a fire. ELECTRICAL REQUIREMENTS A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A timedel

Summary of the content on the page No. 5

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, In- cluding Fire-Rated Construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards su

Summary of the content on the page No. 6

RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION � The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation. � Check that the main voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. � The electrical supply must be properly

Summary of the content on the page No. 7

DIMENSIONS and MAIN PARTS Dimensions       Components   Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters    2 1 Telescopic Chimney comprising:  2.1 1 Upper Section 2.2 1 Lower Section 8a 1 Right Air Outlet Grill Aria 8b 1 Left Air Outlet Grill Aria   10 1 Damper  14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection   Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Se

Summary of the content on the page No. 8

INSTALLATION Wall drilling and bracket fixing         Wall marking: � Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the center of the area in which the hood will be installed. � Draw a horizontal line at 24” above the hob. � Place bracket 7.2.1 on the wall as shown about 1/16” from the ceiling or upper limit aligning the center (notch) with the vertical reference line. � Mark the wall at the centers of the holes in the

Summary of the content on the page No. 9

Mounting the hood body  � Before attaching the hood body, tighten the two screws Vr lo- cated on the hood body mounting points. � Hook the hood body onto the screws 12a. � Fully tighten support screws 12a.  � Adjust screws Vr to level the hood body. Note: The Hood body should be secured to wall studs. If neces- sary, install a wood support behind the dry wall, flush mounted between 2 studs. This will provide the necessary structure and support for mounting. Connections DUCTED VERSION

Summary of the content on the page No. 10

ELECTRICAL CONNECTION � Remove the cover from the Field Wiring Compartment with a    phillips screwdriver.     � Feed the Power Supply Cable through the electrical knockout.     Connect the Power Supply Cable to the range- hood cable. At- tach the Power Supply Cable grounding lead to the green screw provided. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connec- tor. Attach the Black lead of th

Summary of the content on the page No. 11

USE Control board Key Function Display A Switches the motor on and off at the latest Indicates the selected speed selected speed B Decreases the suction speed. - C Increases the suction speed. - D By pressing this key it is possible to start the HI and the remaining time appear alternately. intensive speed from any previously selected The spot down at the right side flashes once a speed. This speed has been timed at 10 min- second. utes. After that time the system activates auto- mat

Summary of the content on the page No. 12

CARE Metal grease filters Filters can be washed in the dishwasher. They need to be washed when FF-sign appears on the display or in any case every 2 months, or even more frequently in case of particularly intensive use of the hood. Alarm reset � Press the G-key for at least 2 seconds. Cleaning � Remove the filters one at a time, supporting them with one hand and turning the safety knobs (pull and turn). � Wash the filters. Pay attention not to bend them. Make sure that filters are co

Summary of the content on the page No. 13

Charcoal filter (ductless version) This filter cannot be washed or regenerated. It has to be replaced when the EF appears on the display or at least once every 4 months. Activation of the alarm signal � In the recycling version hoods the filter saturation alarm has to be activated during the in- stallation or later. � Switch off the hood and the lights. � Press the E-key for about 5 seconds until the LED on the display start to move. � Press the B-key within 5 seconds until a confirmatio


Alternative user manuals
# User manual Category Download
1 Smeg Arco Isola Plus KSEIV96X User manual Ventilation Hood 4
2 Smeg KA9X-1 User manual Ventilation Hood 6
3 Smeg KIV950RX User manual Ventilation Hood 5
4 Smeg KI1207X User manual Ventilation Hood 5
5 Smeg KIV90XT User manual Ventilation Hood 1
6 Smeg KIV90X User manual Ventilation Hood 1
7 Smeg KCVR9NE User manual Ventilation Hood 1
8 Smeg KSE 61X User manual Ventilation Hood 2
9 Smeg K2 User manual Ventilation Hood 0
10 Smeg KSE 71X User manual Ventilation Hood 6
11 Smeg KR37X User manual Ventilation Hood 1
12 Smeg KSE 91X User manual Ventilation Hood 9
13 Smeg KSE90XT User manual Ventilation Hood 2
14 Smeg Kitchen Hood KSE9600XL User manual Ventilation Hood 3
15 Smeg KSE912X User manual Ventilation Hood 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0