Siemens 125-5033 user manual

User manual for the device Siemens 125-5033

Device: Siemens 125-5033
Category: Ventilation Hood
Manufacturer: Siemens
Size: 0.23 MB
Added : 8/21/2014
Number of pages: 35
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens 125-5033. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens 125-5033.

For your convenience

If looking through the Siemens 125-5033 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens 125-5033 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens 125-5033 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens 125-5033 User manual - Online PDF
Advertisement
« Page 1 of 35 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens 125-5033 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens 125-5033. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






Two-State Constant Volume
Fume Hood Controller
Owner’s Manual
125-5033 Rev. AA, September 2007

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Rev. AA, September 2007 NOTICE The information contained within this document is subject to change without notice and should not be construed as a commitment by Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. assumes no responsibility for any errors that may appear in this document. All software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. WARNING This equipment generates, us

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Table of Contents How To Use This Manual ............................................................................................. VII Manual Organization ................................................................................................. VII Manual Conventions .................................................................................................. VII Manual Symbols ............................................................................................

Summary of the content on the page No. 6

Applications .................................................................................................................. 11 Fume Hood Controller: 2-Position Constant Volume ............................................... 11 Basic Operation ............................................................................................................ 12 High and Low Exhaust Flow Control ......................................................................... 12 Control Loops ..........

Summary of the content on the page No. 7

How To Use This Manual This section covers manual organization, conventions, and symbols used in the manual, and other information that will help you understand and use a Laboratory Room Controller — Electronic Output. Manual Organization This manual contains the following sections: • Chapter 1 Product Overview describes the hardware components and the accessories that are used with the controller. • Chapter 2 Applications describes the control applications available in the controll

Summary of the content on the page No. 8

Manual Symbols The following table lists symbols that are used to draw your attention to important information. Notation Symbol Meaning CAUTION: Indicates that equipment damage or loss of data may occur if the user does not follow a procedure as specified. WARNING: Indicates that personal injury or loss of life may occur to the user if a procedure is not performed as specified. Datamate Software Datamate is a customer software tool for all controller communications. There are tw

Summary of the content on the page No. 9

1 Product Overview Introduction The Fume Hood Controller is an equipment controller designed to provide Direct Digital Control (DDC) for 2 position fume hoods. The controller consists of a controller board and a controller enclosure. The controller board (Figure 1) is the central computing/controlling component of the system. Related Equipment • Operator Display Panel (ODP) • Laboratory Exhaust Air Terminal • Venturi Air Valve • Differential Pressure Transmitter (See NOTE) • Air

Summary of the content on the page No. 10

Fume Hood Controller Owner's Manual Table 1. Fume Hood Controller – Electronic Output Applications. Application Description 940 2 Position Fume Hood Controller Ordering Notes Fume Hood Controller – Electronic Output (940) 546-00750 Figure 1. Fume Hood Controller Board . 2 Siemens Building Technologies, Inc.

Summary of the content on the page No. 11

Product Overview Hardware Inputs Analog • Differential pressure transmitter Digital • Operator Display Panel (ODP) • ATTN.UNATTN (through DI1) • OCC.UNOCC (through DI1) Hardware Outputs Analog • AO-E/AO-P module (Floating Control) • Operator Display Panel (ODP) • AO2 (Flow Signal, 1 to 10 Vdc) Digital • FLN communications trunk • DO3 (24 Vac, Alarm/Hi.Low Output) Power Wiring The controller is powered by 24 Vac. Power wiring connects to the three screw terminals on the controll

Summary of the content on the page No. 12

Fume Hood Controller Owner's Manual FLN TRUNK +- S (SHIELD) (SHIELD) (-) (-) 24V COMMON (+) (+) 24V HOT GROUND Figure 2. Power Wiring. Figure 3. Communication Wiring. Controller LED Indicators The controller has six Light Emitting Diode (LED) indicators. See Table 2. Table 2. Controller LEDs. LED Type Label Indication (if present)* DO LED 1 - LED 3 Indicates the ON/OFF status of the DO associated with it. A glowing LED indicates that the DO is energized. Transmit TX Indicates, w

Summary of the content on the page No. 13

Product Overview Pressing the Emergency Purge button a second time reverts the Fume Hood Controller to normal operation for the current conditions. HI/LO: HI/OFF Select button – Pressing this button changes the controller from a high flow setpoint to a low flow setpoint and back again or changes the controller from a high flow setpoint to and OFF state and back again. Auxiliary Button – The Auxiliary buttons are not used currently. For more information on the ODP, see the Fume Hood Contro

Summary of the content on the page No. 14

Fume Hood Controller Owner's Manual The terminal is available in diameters ranging from 4 to 18 inches. The terminal is available in a variety of end configurations to match the ductwork construction. It is also available in ® TEFLON coated 18-gauge steel for highly corrosive environments. Figure 5. Laboratory Exhaust Air Terminal. Venturi Air Valves The Venturi Air Valve is a pre-packaged, easy to install airflow measurement and control station. See Figure 6. This assembly combines t

Summary of the content on the page No. 15

Product Overview High Speed Electronic Actuation The High speed electronic actuator assembly consists of two parts, the electronic actuator and the interface board. The actuator is connected to the exhaust flow control device in the fume hood exhaust duct. The electronic actuator assembly is used because of its small size and quick response time. CAUTION: Due to the design parameters and the response time required by the Fume Hood Controller, the assembly must be replaced with the sam

Summary of the content on the page No. 16

Fume Hood Controller Owner's Manual Low Speed Electronic Actuation Alternately, when speed of response is not an issue, slower speed electronic actuation may be used. This can be used when the change-of-state between High and Low can take place in 15 seconds or more. Low Speed Actuator (GMA13x). Pneumatic Actuation The pneumatic actuator is connected to an exhaust flow control device in the fume hood exhaust duct. The standard pneumatic actuator (Figure 8) used with the Fume Hood Con

Summary of the content on the page No. 17

SUPPLY COMMON EXHAUST S R (SUPPLY) (ACTUATOR) 18-30 PSI Product Overview Figure 8. Pneumatic Actuator. Analog Output-Pneumatic (AO-P) Module The Analog Output-Pneumatic (AO-P) Module is an electric-to-pneumatic interface between the Fume Hood Controller and the pneumatic actuator. The AO-P Module translates electrical signals from the Fume Hood Controller into pneumatic signals that command the actuator. The AO-P Module consists of two industrial grade solenoids that supply or bleed air

Summary of the content on the page No. 18

Fume Hood Controller Owner's Manual NOTE: While the pneumatic actuator is being commanded, you may hear a hissing or clicking sound coming from the AO-P module. This is due to the movement of the air valves and the bleeding of air from the actuator. This is normal operation. Differential Pressure Transmitter The differential pressure transmitter is used to send a signal that represents the velocity of air in the duct to the controller. The differential pressure transmitter receives the ve

Summary of the content on the page No. 19

2 Applications Fume Hood Controller: 2-Position Constant Volume Application 940 is designed for use with a constant volume or two-position fume hood in a manifold fume hood exhaust system. In this application, two position fume hoods have an individual exhaust damper or venturi air valve connected to a central fan. The application modulates the exhaust flow control device to maintain a high or low flow setpoint based on inputs from the ODP (Operators Display Panel), Digital Input, a

Summary of the content on the page No. 20

Fume Hood Controller Owner's Manual Basic Operation The Fume Hood Controller provides Direct Digital Control (DDC) technology for controlling fume hood face velocities in a manifolded fume hood exhaust system. High and Low Exhaust Flow Control The Fume Hood Controller can operate at two different setpoints, described as HI flow and LOW flow setpoints. The low setpoint can be set to zero to send the controller into an OFF mode. The OFF mode shuts off the flow alarms and closes the exhaust


Alternative user manuals
# User manual Category Download
1 Siemens 125-1957 User manual Ventilation Hood 8
2 Siemens LU36152UC User manual Ventilation Hood 2
3 Siemens LC479650UC User manual Ventilation Hood 2
4 Siemens LC479050UC User manual Ventilation Hood 5
5 Sony SH-L35W User manual Ventilation Hood 0
6 Air King AIF8X User manual Ventilation Hood 3
7 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
8 Air King AIF10X User manual Ventilation Hood 0
9 Agilent Technologies 31A User manual Ventilation Hood 0
10 Air King 500CFM User manual Ventilation Hood 0
11 Agilent Technologies 6610XA User manual Ventilation Hood 1
12 Air King AIK14X User manual Ventilation Hood 0
13 Agilent Technologies HP 83621A User manual Ventilation Hood 0
14 Air King 380 CFM User manual Ventilation Hood 38
15 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2