Rangemaster RMG2H90SS user manual

User manual for the device Rangemaster RMG2H90SS

Device: Rangemaster RMG2H90SS
Category: Ventilation Hood
Manufacturer: Rangemaster
Size: 0.54 MB
Added : 5/17/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Rangemaster RMG2H90SS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Rangemaster RMG2H90SS.

For your convenience

If looking through the Rangemaster RMG2H90SS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Rangemaster RMG2H90SS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Rangemaster RMG2H90SS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Rangemaster RMG2H90SS User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Rangemaster RMG2H90SS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Rangemaster RMG2H90SS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



















RMG2H60SS
RMG2H90SS

Instructions Manual




www.rangemaster.co.uk


Summary of the content on the page No. 2

Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................3 CHARACTERISTICS..............................................................................................................................................................4 INSTALLATION .................................................................................................................................

Summary of the content on the page No. 3

RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from in- correct or improper installation.  The minimum safety distance between the cooker top and the extractor hood is 450 mm.  Check that the mains voltage corresponds to that indicated on th

Summary of the content on the page No. 4

CHARACTERISTICS Dimensions 4 EN 4

Summary of the content on the page No. 5

Components Ref. Q.ty Product Components  1 1 Hood Body, complete with: Controls, Light,  Blower, Filters 2 1 Telescopic Chimney comprising:  2.1 1 Upper Section     2.2 1 Lower Section 9 1 Reducer Flange ø 150-120 mm 10 1 Adapting ring ø 120-125 mm 14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets  7.3 1 Air Outlet Connection Support  11 6 Wall Plugs  12

Summary of the content on the page No. 6

INSTALLATION Wall drilling and bracket fixing      Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.  Draw a horizontal line at 1040 mm above the hob.  Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit align- ing the centre (notch) with the vertical reference line.  Mark the wall at the centres of the holes in the

Summary of the content on the page No. 7

Mounting the hood body  Before attaching the hood body, tighten the two screws Vr lo-  cated on the hood body mounting points.  Hook the hood body onto the screws 12a.  Fully tighten support screws 12a.  Adjust screws Vr to level the hood body.  Connections DUCTED VERSION AIR EXHAUST SYSTEM     When installing the ducted version, connect the hood to the  chimney using either a flexible or rigid pipe ø 150 or 125 mm,  the choice of which is left to the installer.

Summary of the content on the page No. 8

ELECTRICAL CONNECTION  Connect the hood to the mains through a two-pole switch hav- ing a contact gap of at least 3 mm.  Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. 7.2.1 Flue assembly 12c Upper exhaust flue  Slightly widen the two sides of the upper flue and hook them 2.1 behind the brackets 7.2.1, making sure that they are well 2 seated. 12c  Secure

Summary of the content on the page No. 9

USE       Control Panel The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button. KEY LED FUNCTIONS L 0/1 Light Turns lighting on and off. T1 0/1 Motor on First speed. When pressed for about 1 seconds the motor is switched off. T2 Speed on Second speed. T3 Speed on Third speed. T4 Speed Fixed Max. speed Flashing Intensive speed. Suitable for the strongest cooking vapours and odours. Th

Summary of the content on the page No. 10

MAINTENANCE REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type.  Do not place the remote control near to heat sources.  Used batteries must be disposed of in the proper manner. Cleaning the Comfort Panels  Pull the Comfort Panel to open it.  Disconnect the panel from the hood canopy by sliding the fix- ing pin lever.  The comfort panel must never be washed in a dishwas

Summary of the content on the page No. 11

Grease filters CLEANING METAL SELF- SUPPORTING GREASE FIL- TERS Alarm signal reset  Switch off the lights and extractor motor.  Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters  The filters are washable and must be cleaned at least every 2 months of operation, or more frequently for particularly heavy usage.  Pull the Comfort Panel to open it.  Remove the filters one at a time by pushing them to- wards the back of the group and pullin

Summary of the content on the page No. 12

Activated charcoal filter (Recirculation version) The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is swi- tched on. Alarm signal activation  In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off.  Disconnect the Hood using the Main switch or the double-pol

Summary of the content on the page No. 13

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Summary of the content on the page No. 16

AGA RANGEMASTER LTD. 436004188_ver1


Alternative user manuals
# User manual Category Download
1 Rangemaster ELTSHDC110SG User manual Ventilation Hood 1
2 Rangemaster L 540 720 User manual Ventilation Hood 0
3 Rangemaster GLX490 RM User manual Ventilation Hood 0
4 Rangemaster GLX390 User manual Ventilation Hood 0
5 Rangemaster L2 515 695 User manual Ventilation Hood 0
6 Rangemaster L1 512 692 User manual Ventilation Hood 0
7 Rangemaster L1 400370 User manual Ventilation Hood 0
8 Rangemaster LEIHDS120SC User manual Ventilation Hood 0
9 Rangemaster RMDD3004EX User manual Ventilation Hood 0
10 Rangemaster E64000 User manual Ventilation Hood 1
11 Rangemaster RMDD3604EX User manual Ventilation Hood 0
12 Rangemaster RMDD3004 User manual Ventilation Hood 0
13 Rangemaster RMDD4804 User manual Ventilation Hood 0
14 Rangemaster RMDD3604 User manual Ventilation Hood 0
15 Rangemaster RMDD4804EX User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0