REI MDC-900 user manual

User manual for the device REI MDC-900

Device: REI MDC-900
Category: Ventilation Hood
Manufacturer: REI
Size: 0.92 MB
Added : 5/17/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for REI MDC-900. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with REI MDC-900.

For your convenience

If looking through the REI MDC-900 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual REI MDC-900 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual REI MDC-900 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
REI MDC-900 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual REI MDC-900 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to REI MDC-900. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Version 4 27 Feb 08



MDC-900
MDC-2100






OWNER’S GUIDE








RESEARCH ELECTRONICS INTERNATIONAL
455 Security Drive
Algood, TN 38506 U.S.A.
+1 931-537-6032
http://www.reiusa.net/
REI MDC-2100/MDC-900 1

Summary of the content on the page No. 2

Version 4 27 Feb 08 TABLE of CONTENTS TABLE OF CONTENTS .................................................................................................... 2 TABLE OF FIGURES ........................................................................................................ 2 INTRODUCTION ............................................................................................................... 3 INSTALLING THE MDC-2100/MDC-900 .................................................

Summary of the content on the page No. 3

Version 4 27 Feb 08 INTRODUCTION The OSCOR Microwave Downconverter option (MDC-2100) expands the OSCOR ’s frequency range limit to 21GHz. The MDC-900 extends the OSCOR ’s range to 9GHz. Note: General descriptions of the MDC-2100 in this guide may not always include exceptions for the MDC-900, which does not cover the 9 to 21GHz spans. Microwave signals tend to be directional; therefore, the MDC-2100 features an array of high gain directional antennas. The MDC is compatible with t

Summary of the content on the page No. 4

Version 4 27 Feb 08 MDC-900 only 3 6 9 12 15 18 21 4.5 7.5 10.5 13.5 16.5 19.5 0 1.5 Antennas All Numbers 3-9* in GHz. 9-15 15-21 *The MDC-900 only covers the band 1 frequency range. Figure 2: ILLUSTRATION OF THE MDC-2100 DOWNCONVERSION PROCESS The OSCOR (version 5.0) displays up to six 1.5GHz (1500MHz) windows simultaneously, or the spectrum may be separated into three an

Summary of the content on the page No. 5

Version 4 27 Feb 08 Installing the MDC-2100/MDC-900 In order to use the MDC with the OSCOR, a special connector (the OEP-2100) must be installed in the connector tray of the OSCOR. This connector should be installed permanently into the connector tray and provides for easy connection of the MDC while not affecting the OSCOR normal operation. Note the step numbers on Figure 4 below to assist in the installation. To install the OEP-2100: 1. Turn the OSCOR off and wait at least 30 seco

Summary of the content on the page No. 6

Version 4 27 Feb 08 Operational Control of the MDC-2100/MDC-900 OSCOR Version 4.0 Operational control of the MDC-2100 is provided by the OSCOR keypad using the normal OSCOR functional control. For example, in the OSCOR SWEEP or ANALYZE modes, pressing the F1 button will toggle through all of the OSCOR inputs including the MDC- 2100 frequency bands. Furthermore, in the SWEEP mode, pressing the RECALL button will display the OSCOR available inputs including the MDC inputs. Some of the o

Summary of the content on the page No. 7

Version 4 27 Feb 08 o You can choose to begin with MDCB-all if you wish. You must view both MDCA- all and MDCB-all to see the entire spectrum. • Set the span to 1.5GHz, if necessary. If a smaller span initially displays, press SWEEP/ANALYZE (CONTROL area) to select SWEEP. Press SHIFT (DATA FUNCTIONS area) and EXPAND (CONTROL area). • Notice any signals displayed. • Select MDCB-all. Use the same options discussed above. • Set the span to 1.5GHz. • Notice any signals displ

Summary of the content on the page No. 8

Version 4 27 Feb 08 Figure 6A: ANALYZING AN MDC SIGNAL (OSCOR 4.0) Figure 6B: ANALYZING AN MDC SIGNAL (OSCOR 5.0) FIGURE 7: USING “IDENTIFY” TO VERIFY A SIGNAL (OSCOR 5.0) OSCOR Sweep and Analyze Modes with the MDC In the Sweep mode, the cursor frequency is no longer representative of a single frequency because of the folding principle described in the introduction of this manual. Therefore, when the entire frequency spectrum is displayed from 3 to 21GHz (MDC-2100) or 3 to 9G

Summary of the content on the page No. 9

Version 4 27 Feb 08 the F4 button to further analyze the signal, it is possible to analyze which antenna and filter that is actually receiving the signal. Figure 9 shows the proper antenna selected and the proper filter selected which corrects the signal shape. Furthermore, the unusual signal shape of Figure 8 indicates that this signal should be a Filter B signal. Note: The OSCOR 5.0 software will not allow this type signal to be displayed. The frequency span limits are always b

Summary of the content on the page No. 10

Version 4 27 Feb 08 Figure 9: SELECTING THE PROPER MDC BAND AND FILTER (OSCOR 4.0) Storing a Sweep Span with the MDC Since the MDC down-conversion process displays multiple frequency bands at once, the easiest way to quickly view a specific frequency span is to type in a desired center frequency and then use the EXPAND and NARROW keys to adjust the span. To store a specific frequency span: 1. Ensure that the OSCOR is in the SWEEP mode and the MDC is connected. 2. Type in the desir

Summary of the content on the page No. 11

Version 4 27 Feb 08 includes the desired frequency span. The table below provides some examples and recommended search span for speed and accuracy. Example of a Desired Frequency Recommended Implementation: Span: 4 – 6GHz 3 – 9GHz (MDCA-1 & MDCB-1/OSCOR 5.0) 6 – 8GHz 3 – 9GHz (MDCA-1 & MDCB-1/OSCOR 5.0) 5.7 – 5.9GHz 5.8 GHz, 250MHz span 8 – 10GHz 3 – 21GHz (MDCA-all & MDCB-all/OSCOR 5.0) 13 – 16GHz 3 – 21GHz (MDCA-all & MDCB-all/OSCOR 5.0) Figure 10; EXAMPLES OF STORING SPANS Stor

Summary of the content on the page No. 12

Version 4 27 Feb 08 Microwave Transmission Considerations for the MDC There are important principles and considerations to understand when dealing with microwave frequency radiators. • As the frequency increases, the penetration of RF signals through building materials, foliage, etc. decreases rapidly. Therefore, microwave signals are considered to be a line-of-sight (LOS) communication link. If you locate a microwave surveillance device, the receiving station will be in the direction

Summary of the content on the page No. 13

Version 4 27 Feb 08 it is absolutely necessary in order to save time. A good rule of thumb is to assume that the MDC has an antenna pattern that is about 100 degrees wide. In other words, it is necessary to point the MDC in at least 4 different directions around the room to cover the perimeter. Also, the MDC should be pointed up and possibly moved around the room to cover the ceiling, and down to cover the floor. Furthermore, if you expect a very sophisticated threat, it is recommende

Summary of the content on the page No. 14

Version 4 27 Feb 08 Using the MTU-2100 Microwave Test Unit The MTU-2100 is designed to provide a simple test to verify that the MDC is working properly. When the button is pressed on the MTU, low power signals are generated at about 5.9, 11.8, and 17.7GHz for 3 minutes. Each transmitted signal contains a modulated tone between 900Hz and 1KHz to verify that the signal is radiating from the MTU-2100. It is important to note that the frequency transmissions from the MTU may drift sligh

Summary of the content on the page No. 15

Version 4 27 Feb 08 MDC-2100/MDC-900 SPECIFICATIONS Specifications MDC-2100 MDC-900 Frequency Range: 3-21GHz 3-9GHz Conversion output: 5MHz to 3005MHz 5MHz to 3005MHz Frequency Bands of Operation: Band 1: 3-9GHz Band 1: 3-9GHz Band 2: 9-15GHz Band 3: 15-21GHz Show All: 3-21GHz Antenna Gain: Band 1: 10 dB Band 1: 10 dB Band 2: 9 dB Band 3: 9 dB MDS - Minimum Detectable Signal including receiver sensitivity, antenna gain, and filtering losses: Band 1: -110 dBm Band

Summary of the content on the page No. 16

Version 4 27 Feb 08 Technical Bulletin 24 April 2002 For the MDC-900 and MDC-2100 This bulletin describes a calibration process to ensure the maximum technical performance for the MDC unit. Technical Background: Most Down-converter products contain a local oscillator (LO) reference signal that is utilized in the down-conversion process. While this LO frequency is vital to the down- conversion process, it also creates a blind spot in the frequency spectrum that cannot be analyze


Alternative user manuals
# User manual Category Download
1 Sony SH-L35W User manual Ventilation Hood 0
2 Air King AIF8X User manual Ventilation Hood 3
3 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
4 Air King AIF10X User manual Ventilation Hood 0
5 Agilent Technologies 31A User manual Ventilation Hood 0
6 Air King 500CFM User manual Ventilation Hood 0
7 Agilent Technologies 6610XA User manual Ventilation Hood 1
8 Air King AIK14X User manual Ventilation Hood 0
9 Agilent Technologies HP 83621A User manual Ventilation Hood 0
10 Air King 380 CFM User manual Ventilation Hood 38
11 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2
12 Air King AD series User manual Ventilation Hood 1
13 AEG DD 8665 User manual Ventilation Hood 4
14 AEG 230 D User manual Ventilation Hood 1
15 Agilent Technologies 51A User manual Ventilation Hood 0