LG Electronics LA120HPO user manual

User manual for the device LG Electronics LA120HPO

Device: LG Electronics LA120HPO
Category: Air Conditioner
Manufacturer: LG Electronics
Size: 13.63 MB
Added : 11/9/2013
Number of pages: 76
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for LG Electronics LA120HPO. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with LG Electronics LA120HPO.

For your convenience

If looking through the LG Electronics LA120HPO user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LG Electronics LA120HPO on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LG Electronics LA120HPO to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LG Electronics LA120HPO User manual - Online PDF
Advertisement
« Page 1 of 76 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LG Electronics LA120HPO but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LG Electronics LA120HPO. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

website http://www.lgservice.com
LG
LG
Room Air Conditioner
SERVICE MANUAL
MODELS: LAN091CNP (ASNC091F2G0)
LAU091CNP (ASUC091FUG0)
LAN121CNP (ASNC121F2G0)
LAU121CNP (ASUC121FUG0)
LAN091HNP (ASNH091F2G0)
LAU091HNP (ASUH091FUG0)
LAN121HNP (ASNH121F2G0)
LAU121HNP (ASUH121FUG0)
LA090CPI (ASNC091F2G0)
LA090CPO (ASUC091FUG0)
LA120CPI (ASNC091F2G0)
LA120CPO (ASUC091FUG0)
LA090HPI (ASNH091F2G0)
LA090HPO (ASUH091FUG0)
LA120HPI (ASNH121F2G0)
LA120HPO (ASUH121FUG0)
CAUTION
• BEFORE SERVICING THE UNIT, REA

Summary of the content on the page No. 2

Air Conditioner Service Manual TABLE OF CONTENTS Safety Precautions...........................................................................................................................................................3 Dimensions.......................................................................................................................................................................9 Symbols Used in this Manual .....................................................................

Summary of the content on the page No. 3

Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. Meanings of symbols used in this manual are as shown below. Be su

Summary of the content on the page No. 4

Safety Precautions Be cautious when unpacking and For installation, always contact Do not install the product on a installing the product. the dealer or an Authorized defective installation stand. Service Center. • Sharp edges could cause injury. Be • There is risk of fire, electric shock, • It may cause injury, accident, or especially careful of the case explosion, or injury. damage to the product. edges and the fins on the con- denser and evaporator. Be sure the installation area Do not

Summary of the content on the page No. 5

Safety Precautions Use a dedicated outlet for this Grasp the plug to remove the Do not place a heater or other appliance. cord from the outlet. Do not appliances near the power cable. touch it with wet hands. • There is risk of fire or electrical • There is risk of fire or electrical • There is risk of fire and electric shock. shock. shock. Do not allow water to run into Do not store or use flammable Do not use the product in a tight- electric parts. gas or combustibles near the air ly clos

Summary of the content on the page No. 6

Safety Precautions Do not open the inlet grill of the When the product is soaked Ventilate the product from time product during operation. (Do (flooded or submerged), contact to time when operating it togeth- not touch the electrostatic filter, an Authorized Service Center. er with a stove, etc. if the unit is so equipped.) • There is risk of physical injury, • There is risk of fire or eletric • There is risk of fire or electrical electric shock, or product failure. shock. shock. Unplug the

Summary of the content on the page No. 7

Safety Precautions Do not install the product where Use two or more people to lift Do not install the product where the noise or hot air from the out- and transport the air conditioner. it will be exposed to sea wind door unit could damage the (salt spray) directly. neighborhoods. • It may cause a problem for your • Avoid personal injury. • It may cause corrosion on the prod- neighbors. uct. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or ine

Summary of the content on the page No. 8

Safety Precautions Always insert the filter securely. Do not insert hands or other Do not drink the water drained Clean the filter every two weeks objects through the air inlet or from the unit. or more often if necessary. outlet while the air conditioner is plugged in. • A dirty filter reduces the efficiency • There are sharp and moving parts • It is not sanitary and could cause of the air conditioner and could that could cause personal injury. serious health issues. cause product malfunc

Summary of the content on the page No. 9

Dimensions Dimensions Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. This symbol indicates special notes. NOTICE Indoor Unit Hanger Hole W D H Fix Hole Pipe Hole Model INDOOR UNIT Dimension W mm(inch) 600(23.6) H mm(inch) 600(23.6) D mm(inch) 146(5.7) Service Manual 9

Summary of the content on the page No. 10

Dimensions Outdoor Unit L2 W L3 Gas side (3-way valve) Liquid side (2-way valve) MODEL 9k, 12k Models DIM unit W mm 770(30.3) H mm 540(21.3) D mm 245(9.6) L1 mm 285(11.2) L2 mm 64(2.5) L3 mm 518(20.4) L4 mm 10(0.4) L5 mm 100(3.9) 10 Room Air Conditioner H L1 D L4 L5

Summary of the content on the page No. 11

Product Specifications Product Specifications AS-C091F2G0(LA091CNP) AS-C121F2G0(LA121CNP) AS-H091F2G0(LA091HNP) AS-H121F2G0(LA121HNP) Models AS-C091F2G0(LA090CP) AS-C121F2G0(LA120CP) AS-H091F2G0(LA090HP) AS-H121F2G0(LA120HP) Cooling Capacity kW 2.87 3.37 2.87 3.37 (Min~Rating~Max) Btu/h 9,800 11,500 9,800 11,500 Heating Capacity kW - - 2.87 3.37 (Min~Rating~Max) Btu/h - - 9,800 11,500 Power Input Cooling/Heating W 980 1,100 980/980 1,100/1,100 Running Current Cooling/Heating A 9.4 10 9.4/9.4

Summary of the content on the page No. 12

Installation Installation Read carefully, and then follow step by step. Installation Parts Installation guide map Type "A" screw and plastic anchor Type "B" screw Remote control holder Installation Tools Figure Name Figure Name Screw driver Ohmmeter Electric drill Hexagonal wrench Measuring tape, Knife Ammeter Hole core drill Leak detector Thermometer, Spanner Horizontal meter Torque wrench Flaring tool set 12 Room Air Conditioner

Summary of the content on the page No. 13

Installation Installation Map NOTICE Installation parts you should purchase. More than More than More than 3.9"(10cm) 3.9"(10cm) 7.9"(20cm) More than 19.6"(50cm) (Left and right Sleeve are identical) Bushing-Sleeve Putty(Gum Type Sealer) Bend the pipe as close as possible on the wall but be careful so that it may not break. Vinyl tape (Wide) • To carry out the drainage test, remove the air filter and pour water into the heat exchanger. Saddle • Apply after carrying out a drain

Summary of the content on the page No. 14

Installation Confirm The Refrigerant 1. Check the quality label on the indoor and outdoor unit. 2. Make certain that the refrigerant is R-410A. NOTICE THIS PRODUCT CONTAINS R-410A REFRIGERANT 1) Different compressor oil - R-410A(Polyol ester) / R-22(Mineral). - Do not mix the existing mineral oil. - Do not apply used pipe, tools and gauges covered with the existing mineral oil. 2) Absorption of moisture -Compressor’s oil has the high absorption rate of moisture. 3) Composition - R-410A(R32:R125=

Summary of the content on the page No. 15

Installation Select the best Location Indoor unit 1. Do not have any heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit. More than More than 7.9"(20cm) 3. Make sure that condensation drainage can be conve- 19.6"(50cm) niently routed away. 4. Do not install near a doorway. 5. Ensure that the interval between a wall and the left More than (or right) of the unit is more than 19.6"(50cm). The More than unit should be installed as high as possible on

Summary of the content on the page No. 16

Installation Piping Length and Elevation Standard Max. Max. Additional Pipe Size Capacity Length Elevation length Refrigerant (Btu/h) Suction Evap m(ft) B m(ft) A m(ft) g/m(oz/ft) 9k, 12k Ø12.7mm(1/2") Ø6.35mm(1/4") 7.5(25) 7.5(25) 15(49) 20(0.22) Indoor unit Outdoor unit Outdoor unit A A Oil trap B Indoor unit Outdoor unit Indoor unit B B If piping length is more than 16.4ft(5m) CAUTION: Capacity is based on standard length and maximum allowance length is on the basis of reliability. Oil trap s

Summary of the content on the page No. 17

Installation Preparing Work for Installation Open panel front 1. Pull the upper part of the front panel. 2. Lift up the panel. 3. To detach the front panel, remove the two screws at the lower part. 4. Detach the front panel from the body. 5. To detach the panel, disconnect the connector at the upper part. Panel Front Connector Cover pipe and cover side remove 1. Please remove the screw of the center tuning cover. 2. Pull up the side cover of desired connecting direction, then cover side is sep

Summary of the content on the page No. 18

INSTALLATION GUIDE MAP INSTALLATION GU INSTAIIATION GUIDE MAP INSTALLATION GUIDE MAP INSTALLATION GUIDE MAP Installation Fixing Indoor Unit 1. Attach an Installation guide map on the 2. Look at suited horizon by horizontal desired surface. meter on the horizontal setting line, and INSTALLATION GUIDE MAP fix lightly the map by adhesive tape. Horizontality 3. Make a hole with a diameter of 6mm and 4. Drill the pierted part as a diameter of 50mm depth of 30-35mm by piercing a screw for connect

Summary of the content on the page No. 19

Flaring work and connection of piping Flaring work and connection of piping Flaring Work Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure. Cutting the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally. 2. Measure the distance between the indoor and the Copper Slanted Uneven Rough pipe outdoor unit. 90° 3. Cut the pipes a little longer than measured distance. 4. Cut the cable 4.9ft(1.5m) lo

Summary of the content on the page No. 20

Flaring work and connection of piping Check Smooth all round 1. Compare the flared work with the figure by. Inside is shiny without scratches 2. If a flared section is defective, cut it off and do flaring work again. = Improper flaring = Inclined Surface Cracked Uneven damaged thickness Even length all round Connecting the Piping Indoor Preparing the indoor unit's piping and drain hose for installation through the wall. 1. Route the indoor tubing and the drain hose in the direction of rear left


Alternative user manuals
# User manual Category Download
1 LG Electronics 3828A20025V User manual Air Conditioner 45
2 LG Electronics -BKE 7630 NS G User manual Air Conditioner 18
3 LG Electronics 3828A20025U User manual Air Conditioner 11
4 LG Electronics 230/208V User manual Air Conditioner 23
5 LG Electronics 6710 YS User manual Air Conditioner 28
6 LG Electronics 3828A22005P User manual Air Conditioner 13
7 LG Electronics A3UH363FA0, A3UC363FA0, AMNH093D4A0, AMNC093D4A0, AMNH123DEA0, AMNC123DEA0, AMNH093APM0, AMNC093APM0, AMNH123APM0, AMNC123APM0 User manual Air Conditioner 1
8 LG Electronics 6720 YS User manual Air Conditioner 0
9 LG Electronics User manual Air Conditioner 7
10 LG Electronics A2UH243FA0(LMU240HE) User manual Air Conditioner 2
11 LG Electronics 3828A30087S User manual Air Conditioner 1
12 LG Electronics A2UC243FA0 (LMU240CE) User manual Air Conditioner 0
13 LG Electronics AMNC093APM0(LMAN090CNS) User manual Air Conditioner 0
14 LG Electronics AMNH123APM0(LMAN120HNS) User manual Air Conditioner 0
15 LG Electronics AMNH093APM0(LMAN090HNS) User manual Air Conditioner 0
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21