NuTone NP60000 user manual

User manual for the device NuTone NP60000

Device: NuTone NP60000
Category: Ventilation Hood
Manufacturer: NuTone
Size: 1.43 MB
Added : 4/29/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for NuTone NP60000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with NuTone NP60000.

For your convenience

If looking through the NuTone NP60000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual NuTone NP60000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual NuTone NP60000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
NuTone NP60000 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual NuTone NP60000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to NuTone NP60000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
HB0026
NP60000 SERIES
! !
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 11.
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
www.nutone.com
V7450 rev. A

Summary of the content on the page No. 2

! ! WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO PERSONS SHOCK OR INJURY TO PERSONS, OBSERVE IN THE EVENT OF A RANGE TOP GREASE THE FOLLOWING: FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the 1. SMOTHER FLAMES with a close-fitting lid, cookie manufacturer. If you have questions, contact the sheet or metal tray, then turn off the burner. manufacturer at the address or telephone number BE CAREFUL TO PREVENT BURNS. IF THE l

Summary of the content on the page No. 3

TABLE OF CONTENTS 1. SELECT BLOWER OPTION AND INSTALL DUCTWORK............................................................................6 2. MEASURE INSTALLATION...................................................................................................................7 3. PREPARE THE INSTALLATION .............................................................................................................7 4. INSTALL BACKSPLASH ...........................................................

Summary of the content on the page No. 4

- NP60000 SERIES RANGE HOOD SYSTEM - INTERIOR BLOWERS Model 647 Model 634 or 644 Model 437 Model 441 (High capacity roof cap) (10’’ round wall cap) (7” round wall cap) (roof cap) Model 418 Model 415 (10” round adjustable elbow) (7” round adjustable elbow) Model 410 Model 407 (10” round duct—2 ft. sections) (7” round duct—2 ft. sections) Model 427 Model 423 Model 424 Model 454 Model 453 1 1 1 1 1 1 1 1 1 1 (4 /2” x 18 /2” (4 /2” x 18 /2” to (4 /2” x 18 /2” to (4 /2” x 18 /2” (4 /2” x 18 /2” to

Summary of the content on the page No. 5

- NP60000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERS Model 441 Model 437 Model HLB9 (800 cfm) (10” round wall cap) (High capacity roof cap) Model 335 (1200 cfm) or HLB11 (1100 cfm) or 336 (1500 cfm) in-line blower exterior blower Model 331H (600 cfm) (includes two 8” x 12” to or 332H (900 cfm) 10’’ round transitions) exterior blower Model 441 (10” Round wall cap) Model HLB6 (600 cfm) in-line blower (includes two 4 ½” x 18 ½” to 10’’ round transitions) Model 421 Model 418 (10” roun

Summary of the content on the page No. 6

1. SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in-line blower may be used with this hood. The NuTone Premier 60000 Series must be installed with blower models RM325H, RM326H, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately). NOTE: In addition to the blower models listed above, this hood is also compatible with older internal versions 325H and 326H. However, discard the installation instru

Summary of the content on the page No. 7

2. MEASURE INSTALLATION Dimensions for the most common installation are shown below. The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion. Standard 8 ft. (2.44 m) ceiling Standard 18" 18" (457 mm) H (457 mm) over-cooktop 19" cabinet (483 mm) Top of wood mounting strip Hood RMP Series Backsplash (optional) 24" (610 mm) Stan

Summary of the content on the page No. 8

4. INSTALL BACKSPLASH (OPTIONAL) (Optional) RMP Series Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop. (See instructions packed with backsplash.) 5. INSTALL WOOD MOUNTING STRIP Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustratio

Summary of the content on the page No. 9

9. INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL BLOWERS) Run power cable to installation location. Refer to the instructions included with the selected blower or rough-in kit (sold separately) for details on 2 installing the rough-in plate. Install the rough-in plate so that the wiring 1 1 box is located on the right side as you are facing the hood. For ducting through back of hood, remove existing plate from inside 3 4 back of hood and attach it to inside top of hood to cover hole. Secure to 1 t

Summary of the content on the page No. 10

13. INSTALL LIGHT BULBS AND WARMING LAMPS Install (2) heat lamp bulbs. Use BR40 size, 250 W max., infrared bulbs only (sold separately). Install (3) halogen light bulbs. Use PAR20 size, 50 W (sold separately). 14. INSTALL FILTERS CAUTION Remove protective plastic film covering filters before installing them. It is recommended to install side filters first and finish with center one(s). 1. Insert upper end of filter into the hood (finger sized cup side). 2. Raise lower end toward the inside of ho

Summary of the content on the page No. 11

15. USE AND CARE 16. OPERATION Grease Filters Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run The grease filters should be cleaned frequently. Use a for a few minutes to clear the air after you turn off the range. warm detergent solution. Grease filters are dishwasher This will help keep the whole kitchen cleaner and brighter. safe. Wash more often if your cooking style generates greater grease—like frying foods or wok cookin

Summary of the content on the page No. 12

17. SERVICE PARTS 19 20 18 16 17 10 13 21 15 2 19 11 3 5 12 4 7 14 6 6 9 1 8 1 HL0031 KEY PART QTY (HOOD WIDTH) NO. NUMBER DESCRIPTION 30’’ 36’’ 42’’ 48’’ 54’’ 60’’ 66’’ 72’’ 1 V02264 SOCKET LAMP 55 5 5 5 5 5 5 2 V02773 MALE CONNECTOR 11 1 1 1 1 1 1 3 V02772 FEMALE CONNECTOR 11 1 1 1 1 1 1 4 V03435 THERMOSTAT 11 1 1 1 1 1 1 5 V03436 THERMOSTAT BRACKET 11 1 1 1 1 1 1 6 V02563 SPST SINGLE SWITCH FOR WARMING LAMPS 22 2 2 2 2 2 2 7 V03502 SPST DOUBLE SWITCH FOR HALOGEN LAMP 11 1 1 1 1 1 1 8 V03503 S


Alternative user manuals
# User manual Category Download
1 NuTone 671R User manual Ventilation Hood 1
2 NuTone 672R User manual Ventilation Hood 0
3 NuTone 695 User manual Ventilation Hood 0
4 NuTone 761WHNT User manual Ventilation Hood 0
5 NuTone 8663RF User manual Ventilation Hood 0
6 NuTone 8663RFT User manual Ventilation Hood 0
7 NuTone 696N User manual Ventilation Hood 1
8 NuTone 8664RP User manual Ventilation Hood 4
9 NuTone 8663RP User manual Ventilation Hood 2
10 NuTone 755NT User manual Ventilation Hood 0
11 NuTone 768CHNT User manual Ventilation Hood 0
12 NuTone 8832SA User manual Ventilation Hood 0
13 NuTone 8814R User manual Ventilation Hood 2
14 NuTone 8673RP User manual Ventilation Hood 0
15 NuTone 8833 User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0