NuTone NP50000 user manual

User manual for the device NuTone NP50000

Device: NuTone NP50000
Category: Ventilation Hood
Manufacturer: NuTone
Size: 1.51 MB
Added : 4/29/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for NuTone NP50000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with NuTone NP50000.

For your convenience

If looking through the NuTone NP50000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual NuTone NP50000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual NuTone NP50000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
NuTone NP50000 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual NuTone NP50000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to NuTone NP50000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

NP50000
Series
ENGLISH .......................................2
FRANÇAIS .................................12
ESPAÑOL ..................................22
Broan-NuTone LLC. 926 West State Street, Hartford, WI 53027
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227
To Register this Product Visit www.Nutone.com

Summary of the content on the page No. 2

READ AND SAVE THESE INSTRUCTIONS ! ! INTENDED FOR DOMESTIC COOKING ONLY WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When

Summary of the content on the page No. 3

! CAUTION 1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 5. To avoid motor bearing damage and noisy and/or unbalanced impellers,

Summary of the content on the page No. 4

8 - Mounting Screws PREPARE THE HOOD (4.8 x 38mm Pan Head) 4 - Mounting Screws Unpack hood and check contents. (3.9 x 9.5mm Pan Head) You should receive: 8 - Drywall Anchors 1 - Hood 1 - Plenum 1 - Decorative Flue Assembly 4 - Mounting Screws 1 - Adapter (3.4 x 15mm Flat Head) 2 - Non-ducted recirculation filters 2 - Mounting Screws 1 - Parts Bag (B080810471) containing: (3.9 x 6mm Flat Head) 1 - Mounting Bracket 1 - Installation Instructions 1 - Discharge Collar 1 - Flue Mounting Bracket ADAPT

Summary of the content on the page No. 5

INSTALL THE DUCTWORK ROOF CAP (DUCTED HOODS ONLY) ROUND NOTE: To reduce the risk of fire, use only DUCT metal ductwork. 1. Decide where the ductwork will run between the hood and the outside. DECORATIVE WALL 2. A straight, short duct run will allow the hood FLUE CAP to perform most efficiently. 3. Long duct runs, elbows, and transitions will HOOD reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 6” 24”

Summary of the content on the page No. 6

36 3/4” to 42 3/4” above cooktop INSTALL MOUNTING BRACKET FRAMING BEHIND DRYWALL 1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure: a) the framing is centered over installation location. b) the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown. 2. After wall surface is finished, secure mounting bracket to framing using dimensions shown. 36 3/4"= bottom of hood 24" above cooktop NOTE: 42 3/4"= b

Summary of the content on the page No. 7

2. Attach an adequate length of 6” round steel UPPER UPPER ducting to the range hood duct connector. FLUE FLUE Fig.6 VENTS 3. Duct tape all joints to make them secure EXPOSED and air tight. LOWER FLUE UPPER FLUE 4. Carefully place the lower decorative flue VENTS into the recessed area of the range hood CONCEALED top. Fig. 7 5. Carefully slide the upper decorative flue down inside the lower flue. Fig. 7 fig.7 PREPARE THE HOOD NON - DUCTED CONFIGURATION Note: The following materials must be purc

Summary of the content on the page No. 8

PREPARE THE HOOD PLENUM NON - DUCTED CONFIGURATION, cont’d. 8. Carefully place the lower decorative flue into the recessed area of the range hood top. Fig.7 9. Carefully slide the upper decorative flue down inside the lower flue. Note: air vents must be up. Fig.7 4 FLAT 10.Secure the recirculation plenum to the HEAD upper flue with (4) flat head screws. Fig.9 SCREWS (3.4x15 mm) UPPER FLUE fig.9 INSTALL THE HOOD Note: at least two people will be required to mount the hood. 1. Raise the hood in

Summary of the content on the page No. 9

NON-DUCTED RECIRCULATION FILTERS INSTALLATION 1.Non-ducted recirculation filters (B03300487) is included. 2. Position the filters over the blower. 3. Rotate to lock filters in place. NON-DUCTED RECIRCULATION FILTERS fig.12 MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit. Grease Filter The grease filter should be cleaned frequently. Use a warm detergent solution. Grease filter is dishwasher safe. GREASE FILTER Remove filter by pushing filter towards the

Summary of the content on the page No. 10

OPERATION BLOWER LIGHT SWITCH SWITCH PILOT Controls LAMP The hood is operated using the slide controls under the bottom of the hood. The light switch turns the lamps on and off. 01 01234 The blower switch: makes it possible to select the motor operating speed. Position 0: motor off. The pilot lamp lights up whenever the blower is on. fig.14 HEAT SENTRY™ Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessiv

Summary of the content on the page No. 11

WARRANTY BROAN-NUTONE LLC ONE YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone LLC will, at its option, repair or r

Summary of the content on the page No. 12

LISEZ ET CONSERVEZ CES INSTRUCTIONS ! ! SEULEMENT POUR UTILISATION DOMESTIQUE AVERTISSEMENTS POUR REDUIRE LES RISQUES D’INCENDIE, DE DECHARGES ELECTRIQUES OU DE DOMMAGES AUX PERSONNES, OBSERVEZ LES INSTRUCTIONS SUIVANTES: 1. N’utilisez cet appareil que comme cela est indiqué par le constructeur. Si vous avez des problèmes, contactez le fabriquant à l’adresse ou au numéro de téléphone indiqués dans la garantie. 2. Avant de pourvoir à l’entretien ou au nettoyage de votre appareil, éteig

Summary of the content on the page No. 13

4. Utilisez un extincteur SEULEMENT si: A. Vous savez que vous avez un extincteur Classe ABC, et vous en connaissez déjà le mode d’emploi. B. Ce n’est pas un très gros incendie et qu’il se limite à l’endroi où il a explosé. C. Vous êtes en train d’avertir les pompiers. D. Vous avez la possibilité d’essayer d’éteindre l’incendie en ayant le dos tourné vers une issue. * D’après les “Suggestions concernant la Sécurité contre les incendies des cuisines” publiées par NFPA. ! ATTENTION 1. Pour

Summary of the content on the page No. 14

8 - Vis d’assemblage PREPAREZ LA HOTTE (4.8 x 38mm Tête ronde) 4 - Vis d’assemblage Enlever la hotte dans l’emballage et (3.9 x 9.5mm Tête ronde) controller le contenu. 8 - Chevilles Vous devez recevoir : 1 - Espacement 1 - Hotte 4 - Vis d’assemblage 1 - Conduit décoratif (3.4 x 15mm Tête plate) 1 - Adaptateur 2 -Vis d’assemblage 2 - Filtres version recyclant l’air (3.9 x 6mm Tête plate) 1 - Sachet (B080810471) avec: 1 - Instructions pour l’installation 1 -Étrier d’assemblage 1 -Collier d’évacu

Summary of the content on the page No. 15

INSTALLATION DES CONDUITS CHATIÈRE AU (UNIQUEMENT POUR LES HOTTES PLAFOND CARÉNÉES) CONDUIT ROND REMARQUE: pour réduire les risques d’incendie, utilisez uniquement des conduits métalliques. 1. Choisissez l’endroit où passera le conduit CARNEAU CHATIÈRE DÉCORATIF pour relier la hotte à l’extérieur. MURALE 2. Un conduit court et droit permet un HOTTE meilleur rendement de la hotte. 3. En revanche, les longs conduits formant des coudes et plusieurs sections réduisent ses performances. Utilisez le n

Summary of the content on the page No. 16

de 36 3/4”(93,5cm) à 42 3/4”(109cm) au-dessus du plan de cuisson INSTALLATION DES ETRIERS CADRE POUR LE MUR D’ASSEMBLAGE 1. Construisez un cadre en bois pour le mur dont les vis-pivot ne dépassent pas. Assurez-vous: a) que le cadre est centré au-dessus de l’emplacement de l’installation. b) la hauteur du cadre permettra que les étriers d’assemblage soient fixés au cadre en respectant les dimensions indiquées. 2. Après avoir terminé la surface du mur, fixez les étriers d’assemblage au cadre en re

Summary of the content on the page No. 17

CONFIGURATION CARÉNÉE PRISES D’AIR CARNEAU SUPÉRIEURES SUPÉRIEUR 1. Installez le collet de refoulement dans le VISIBLES conduit relié à la hotte (fig.6). CARNEAU PRISES INFÉRIEUR 2. Attachez un conduit arrondi en acier D’AIR d’une longueur de 6" au connecteur du SUPÉRIEURES DISSIMULÉES conduit de la hotte (fig.6). 3. Reliez toutes les sections pour empêcher le passage de l’air. 4. Placez précautionneusement le carneau décoratif inférieur dans la partie de la hotte en retrait (fig.7). 5. Faites g

Summary of the content on the page No. 18

PRÉPARATION DE LA HOTTE ESPACEMENT CONFIGURATION NON CARÉNÉE (suite). 8. Placez précautionneusement le carneau décoratif inférieur dans la partie de la hotte en retrait (fig.7). 9. Faites glisser lentement le carneau décoratif à l’intérieur du conduit inférieur. Remarque: les prises d’air doivent être 4 VIS À tournées vers le haut (fig.7). TÊTE 10.Fixez l’espacement de recirculation au FRAISÉE carneau supérieur au moyen de quatre (4) (3.4x15 mm) vis à tête fraisée (fig.9). CARNEAU SUPÉRIEUR fig.

Summary of the content on the page No. 19

ASSEMBLAGE DES FILTRES VERSION RECYCLANT L’AIR 1. Les filtres version recyclant l’air (B03300487) sont fourni. 2. Placez les filtres au-dessus du ventilateur. Grâce à un mouvement rotatif, fixez les filtres à leur place. FILTRES VERSION RECYCLANT L’AIR fig.12 ENTRETIEN Un bon entretien de votre hotte garantira une excellente performance. Filtre anti-graisse Le filtre anti-graisse doit être nettoyé fréquemment. Utilisez une solution contenant un détergent tiède. Le filtre anti-graisse peut être

Summary of the content on the page No. 20

FONCTIONNEMENT BLOWER LIGHT SWITCH SWITCH PILOT Commandes LAMP La hotte peut être manœuvrée à l’aide des curseurs situés sous la partie inférieure de la hotte. 01 01234 L’interrupteur de la lumière allume et éteint les lampes. L’interrupteur du ventilateur permet de sélectionner la vitesse de marche du moteur. Position 0: moteur éteint. Le voyant lumineux s’allume quand le fig.14 ventilateur fonctionne. MC HEAT SENTRY MC Votre hotte est munie d’un thermostat HEAT SENTRY . Ce thermostat est un di


Alternative user manuals
# User manual Category Download
1 NuTone 671R User manual Ventilation Hood 1
2 NuTone 672R User manual Ventilation Hood 0
3 NuTone 695 User manual Ventilation Hood 0
4 NuTone 761WHNT User manual Ventilation Hood 0
5 NuTone 8663RF User manual Ventilation Hood 0
6 NuTone 8663RFT User manual Ventilation Hood 0
7 NuTone 696N User manual Ventilation Hood 1
8 NuTone 8664RP User manual Ventilation Hood 4
9 NuTone 8663RP User manual Ventilation Hood 2
10 NuTone 755NT User manual Ventilation Hood 0
11 NuTone 768CHNT User manual Ventilation Hood 0
12 NuTone 8832SA User manual Ventilation Hood 0
13 NuTone 8814R User manual Ventilation Hood 2
14 NuTone 8673RP User manual Ventilation Hood 0
15 NuTone 8833 User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0