Marley Engineered Products 3038R user manual

User manual for the device Marley Engineered Products 3038R

Device: Marley Engineered Products 3038R
Category: Ventilation Hood
Manufacturer: Marley Engineered Products
Size: 0.32 MB
Added : 12/10/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Marley Engineered Products 3038R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Marley Engineered Products 3038R.

For your convenience

If looking through the Marley Engineered Products 3038R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Marley Engineered Products 3038R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Marley Engineered Products 3038R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Marley Engineered Products 3038R User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Marley Engineered Products 3038R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Marley Engineered Products 3038R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

READ & SAVE THESE INSTRUCTIONS
MODELS
2438, 3038R & 3638R
WHOLE HOUSE VENTILATORS
CEILING INSTALLATION ONLY
NOTE: MODELS 3038R AND 3638R ARE AVAILABLE
FOR CEILING AND WALL INSTALLATION.
HOT AIR OUT
HOT AIR OUT
COOL AIR IN
COOL AIR IN
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
INTRODUCTION
Your Whole House Ventilator is designed and engineered to provide years of satisfactory service
in cooling and ventilating your entire

Summary of the content on the page No. 2

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Do not use this fan with any Solid-State Speed Control Device. 2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 3. Before servicing or cleaning this unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. 4. Installation work and electrical

Summary of the content on the page No. 3

ATTIC AIR INTAKE AND DISCHARGE Your Whole House Ventilator will be discharging a large volume of air into the attic every minute. Provisions must be made to allow this air to escape to the outside. The sketches below illustrate several different types of exhaust vents that are in common usage. Of these types, the under-eave and gable methods are the most prevalent. Under-eave is probably the most satisfactory from the standpoint of simplicity and economical installation. Make sure under-eave ven

Summary of the content on the page No. 4

CEILING INSTALLATION — MODEL 3038 USED WITH AN A3024 SHUTTER ONLY NO FRAMING OR CUTTING OF JOISTS REQUIRED FOR 16” O.C. JOISTS. FAN LOCATION AND MOUNTING STEP 1 - Fan should be located in center of house, preferably in hallway or corridor. This will allow air to be drawn from all parts of living space. (See Fig. 1). Determine tentative location of fan and proceed as shown below. OVERLAP AREA PILOT HOLES FIG. 1 FIG. 2 FAN FIG. 3 18” MIN. CLEARANCE STEP 2 - Determine joist direction and locate cen

Summary of the content on the page No. 5

FOR CEILINGS WITH JOISTS ON 16” CENTERS MODEL A3024 SHUTTER 2 X 2 X 40 FILLERS EXISTING EXISTING 2 X 6 JOISTS FIG. 4 FIG. 5 2 X 4 JOISTS (DO NOT CUT!) (DO NOT CUT!) FOR CEILINGS WITH JOISTS ON 24” CENTERS MODEL A3024 SHUTTER 2 X 6 FRAMING 2 X 6 FRAMING 2 X 2 X 40 FILLER EXISTING FIG. 6 FIG. 7 2 X 6 JOISTS EXISTING (DO NOT CUT!) 2 X 4 JOISTS (DO NOT CUT!) STEP 5A - If the access opening into the attic is not large enough for the fan to pass through, the fan may be disassembled and lifted into the

Summary of the content on the page No. 6

In attic reassemble channels and housing with the original bolts and lockwashers. Tighten these bolts securely. FIG. 8 FIG. 9 STEP 5B - With fan in attic remove adhesive backing from 1/2” x 1/2” gasket material and attach to the two bottom flanges of fan which will rest on the joists. (Fig. 10.) Install grommet in bracket (Fig. 10) and attach on each end of fan, using two of the short screws provided. Position fan over opening so that grom- mets are resting against center joist. Attach fan and b

Summary of the content on the page No. 7

SHUTTER INSTALLATION STEP 7 - Unpack Model A3024 shutter and read instructions included. Note that the first part of the shutter instructions refer to cutting the shutter hole, which you have already done, and so they may be disregard- ed. Follow the remaining instructions to adjust springs so that shutters open and close freely. (See Fig. 12.) SPRING ATTACHED FIG. 12 CONNECTOR SPRING HOLDER LOCKING SCREW SPRING SHOWN UNATTACHED STEP 8 - Mount shutter to joists directly below fan opening with wo

Summary of the content on the page No. 8

CEILING INSTALLATION — ALL OTHER MODELS FAN LOCATION & MOUNTING STEP 1 - Fan should be located in center of house, preferably in hallway or corridor. This will allow air to be drawn from all parts of living space. (See Fig. 1.) FIG. 1 FIG. 2 OVERLAP AREA PILOT HOLE FAN STEP 2 - Lightly mark a square opening on ceiling (with pencil) where shutter is to be located. Select open- ing size from chart below on Page 1. Check to be sure at least 1 1/2 inches of clearance area is available on all sides f

Summary of the content on the page No. 9

MODEL 2438 FOR CEILINGS WITH 2 X 4 FIG. 5 JOISTS ON 16” CENTERS 2 X 6 Determine which ceiling joists are to be cut per STEPS 2 & 3. FRAMING Locate your fan size below and follow specific instructions. MODEL 3038R WITH MODEL 3230 SHUTTER 2 X 2 FILLER 2 X 6 FRAMING Cut ceiling joists to allow 2 x 6 frame box with 24 3/4” x 24 3/4” inside opening. MODEL 3638R FIG. 6 2 X 6 Cut ceiling joists (as shown) to allow 2 x 6 frame box FRAMING with 30 3/4” x 30 3/4” inside opening. Add 2 x 2 filler to each s

Summary of the content on the page No. 10

FOR CEILINGS WITH 2 X 4 JOISTS ON 24” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3. Locate your fan size below and follow specific instructions. Frame inside opening per chart below. FAN MODEL INSIDE OPENING 2438 24 3/4” X 24 3/4” 2 X 6 3038R* 30 3/4” X 30 3/4” FRAMING 3638R 36 3/4” X 36 3/4” FIG. 11 Proceed to STEP 4. FOR CEILINGS WITH 2 X 6 JOISTS ON 24” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3. Locate your fan size below and follow specific

Summary of the content on the page No. 11

SHUTTER INSTALLATION STEP 6 - Unpack shutter and read instructions included. Carefully follow these instructions to adjust the spring tension on your shutter. Make sure the shutter opens and closes freely. STEP 7 - Insert shutter into opening from below and secure with wood screws provided. See Fig. 16. Make sure there is clearance between spring holder on shutter and the fan blade. Again, make sure that shutter opens and closes freely. STEP 8 - Fan installation is now complete. With control in

Summary of the content on the page No. 12

FAN MOTOR OUTLET BOX CONTROL OUTLET BOX FIG. 15 CONTROL BLACK (HI) BLACK (HI) MOTOR BLUE (MED) BLUE (MED) RED (LOW) RED (LOW) WHITE (COM) BROWN BLACK 120V, 60 HZ WHITE GND. SCREW 120V SUPPLY AVAILABLE AT CONTROL STEP 4 - After determining which diagram applies, pull wires to fan. Be sure to secure cable at fan to pre- vent it being caught in the blade. Make connections to fan and control. After wiring of fan and control is completed and checked against the appropriate wiring diagram, replace out

Summary of the content on the page No. 13

STEP 5—Position fan on frame and secure with (4) wood or lag screws (number 12 x 1 1/2” preferred) through holes drilled in STEP 4. DOUBLE 2 X 6 HEADER SECURE UNIT IN PLACE WITH 2” X 2” FURRING STRIPS INSIDE. SEE CHART 2 X 4 FRAMING SECURE UNIT IN PLACE OUTSIDE WITH MOULDING FIG. 5 FIG. 4 STEP 6—Unpack shutter and read the instructions included. Carefully follow these instructions to adjust the spring tension on your shutter. Make sure the shutter opens and closes freely. STEP 7—Stand assembly u

Summary of the content on the page No. 14

ACCESSORY CONTROL MODEL 1012A Timer Switch may be used to control the fan, if it is desirable to run the fan after retiring at night. Time switch can be set manually to run up to 12 hours, turning fan off automatically at the pre-set time. OPERATING HINTS AND SUGGESTIONS 1. Never operate your Whole House Ventilator with all outside doors and windows closed. Air will be drawn down the chimney bringing soot into the house. This could also impair fuel gas ventilation of furnaces, water heaters, et

Summary of the content on the page No. 15

REF. DESCRIPTION QTY. MODEL REF. DESCRIPTION QTY. MODEL NO. USED ON NO. USED ON 133” V-Belt, FHP 4L330 1 2438 14* Screw, 10-16 x 1/4” Type B 2 ALL 33” V-Belt FHP 4L370 1 3038, 3038R 15 Bracket, Capacitor 1 ALL 44” V-Belt FHP 4L440 1 3638, 3638R 16 Capacitor, 10 MFD 370V 1 2438, 3038, 3038R 2 Sheave, 4” OD Motor 1 2438 Capacitor, 12.5 MFD 370V 1 3638, 3638R Sheave, 3.5” OD Motor 1 3038, 3038R 17 Boot, Capacitor Terminal Cover 1 ALL Sheave, 3” OD Motor 1 3638, 3638R 18 Mount, Motor 1 ALL 3 Sheave,

Summary of the content on the page No. 16

LIMITED WARRANTY Dear Customer, Thank you for your interest in Marley Engineered Products products. We’re sure you will 3. The Marley Engineered Products Service Representative will determine the best way enjoy its benefits for many years to come. Please take a minute to fill out the following to resolve the difficulty. information and keep it in your permanent records. Date Purchased Date Installed Products within warranty which have been installed an


Alternative user manuals
# User manual Category Download
1 Marley Engineered Products 2438 User manual Ventilation Hood 0
2 Marley Engineered Products 5200-2409-001 User manual Ventilation Hood 0
3 Marley Engineered Products A24DD User manual Ventilation Hood 0
4 Marley Engineered Products 898L User manual Ventilation Hood 0
5 Marley Engineered Products PATTON GV 16 User manual Ventilation Hood 0
6 Marley Engineered Products Environmental Series User manual Ventilation Hood 0
7 Marley Engineered Products 3638R User manual Ventilation Hood 0
8 Sony SH-L35W User manual Ventilation Hood 0
9 Air King AIF8X User manual Ventilation Hood 3
10 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
11 Air King AIF10X User manual Ventilation Hood 0
12 Agilent Technologies 31A User manual Ventilation Hood 0
13 Air King 500CFM User manual Ventilation Hood 0
14 Agilent Technologies 6610XA User manual Ventilation Hood 1
15 Air King AIK14X User manual Ventilation Hood 0