Lifebreath RNC120D user manual

User manual for the device Lifebreath RNC120D

Device: Lifebreath RNC120D
Category: Ventilation Hood
Manufacturer: Lifebreath
Size: 3.07 MB
Added : 11/1/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lifebreath RNC120D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lifebreath RNC120D.

For your convenience

If looking through the Lifebreath RNC120D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lifebreath RNC120D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lifebreath RNC120D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lifebreath RNC120D User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lifebreath RNC120D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lifebreath RNC120D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics
RNC Series
Models
RNC95
RNC155
RNC200
RNC10
RNC20
RNC120D
RNC5-TPD
Residential Heat Recovery Ventilators (HRV)
Manufactured with
2 Speed RNC Electronics
TI-RNC
0108

Summary of the content on the page No. 2

Table of Contents Introduction Introduction.........................................................................2 The Lifebreath HRV (Heat Recovery Ventilator) is designed to introduce fresh outdoor air into a building while exhausting an Engineering Data - RNC95 .............................................3-4 equal amount of stale indoor air. Engineering Data - RNC155...............................................5 During the heating season, heat energy from the stale Engineering Data - R

Summary of the content on the page No. 3

Engineering Data - HRV Model RNC95 THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for Net supply air flow in cfm (L/s) against external static pressure cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has one centrifugal blower driven by a common PSC motor. 2 speed fan operation. @ 0.1" (25 Pa) 76 (36) FILTERS Washable air

Summary of the content on the page No. 4

Port Configuration and Airflow Model RNC95 In order to make the RNC95 as space efficient as possible, the RNC95 Specifications INDOOR supply and return ports are converted from round to The RNC95 HRV (Heat Recovery Ventilator) has been designed oval shape. Overall size of the port remains the same. Simply to allow the installer to choose between two possible positions bend a standard duct fitting to the correct shape, and attach to on the cabinet for the Stale Air Exhaust (from building) port. t

Summary of the content on the page No. 5

Engineering Data - HRV Model RNC155 THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two air streams. Net supply air flow in cfm (L/s) against external static pressure It is easily removed for cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has one centrifugal blower driven by a common PSC motor. 2 speed fan operation. @ 0.1" (25 Pa) 150 (71) FILTERS @ 0.2" (

Summary of the content on the page No. 6

Engineering Data - HRV Model RNC200 THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two air streams. Net supply air flow in cfm (L/s) against external static pressure It is easily removed for cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has one centrifugal blower driven by a common PSC motor. 2 speed fan operation. @ 0.1" (25 Pa) 207 (97) FILTERS @ 0.2" (

Summary of the content on the page No. 7

Engineering Data - HRV Model RNC10 THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two air streams. It is easily removed for Net supply air flow in cfm (L/s) against external static pressure cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has one centrifugal blower driven by a common PSC motor. 2 speed fan operation. @ 0.1" (25 Pa) 177 (83) FILTERS @ 0.2" (50

Summary of the content on the page No. 8

Engineering Data - HRV Model RNC20 THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two air streams. Net supply air flow in cfm (L/s) against external static pressure It is easily removed for cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has one centrifugal blower driven by a common PSC motor. 2 speed fan operation. @ 0.1" (25 Pa) 214 (101) FILTERS @ 0.2" (

Summary of the content on the page No. 9

Engineering Data - HRV Model RNC5-TPD THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (H.V.I. certified) The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for Net supply air flow in cfm (L/s) against external static pressure cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has an independent motorized impeller. 2 speed fan operation. @ 0.1" (25 Pa) 169 (80) FILTERS @ 0.2" (50 Pa) 156 (73)

Summary of the content on the page No. 10

Engineering Data - HRV Model RNC120D THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE Performance (HVI certified) The cross-flow heat recovery core transfers heat between the two airstreams. Net supply air flow in cfm (L/s) against external static pressure It is easily removed for cleaning or service. E.S.P MOTORS AND BLOWERS (external static pressure) [cfm (L/s)] Each air stream has an independent motorized impeller. 2 speed fan operation. @ 0.1" (25 Pa) 142 (67) @ 0.2" (50 Pa) 137 (64) FILTERS @

Summary of the content on the page No. 11

Engineering Data - HRV Model RNC120D Option 1 - Horizontal Duct Configuration Dimensions inches STALE FRESH AIR AIR TO FROM OUTSIDE OUTSIDE HANGING STRAPS STALE AIR FROM BUILDING FRESH AIR TO BUILDING 25 1/8” (637 mm) BOTTOM VIEW FOR HORIZONTAL MOUNT SERVICE CLEARANCE FROM BOTTOM STALE AIR OF UNIT IS MINIMUM 3’0” TO OUTSIDE FRESH AIR TO BUILDING FRESH AIR FROM OUTSIDE STALE AIR FROM BUILDING ALL DUCT COLLARS ACCESS DOOR ARE 5” DIAMETER SIDE VIEW FOR HORIZONTAL MOUNT Connect drain hose to spou

Summary of the content on the page No. 12

Remote Control Devices Optional Main Control Features The Dehumidstat The amount of ventilation required in your home will fluctuate Main controls feature a dehumidistat which is used to reduce high according to the activity level in the house. Higher activity levels indoor humidity levels during the heating season. The control has a require more ventilation. selector knob with setpoints ranging from 20% to 80% relative humidity (RH). Most people are comfortable when indoor relative Main control

Summary of the content on the page No. 13

31" (787) Locating and Suspending the HRV Location Selection Suspending the HRV The HRV must be located in a heated space where it will be The hanging straps should be attached to the unit at the top end possible to conveniently service the unit. Typically the HRV corners (mounting screws are already located on the HRV case). would be located in the mechanical room or an area close to the Securely fasten the other end of the straps to the floor joists with outside wall where the weather hoods wi

Summary of the content on the page No. 14

Suspending the RNC120D Horizontal Installation ATTENTION The unit must be mounted level for proper drainage of the condensate pans. JOIST FASTENERS (not supplied) STRAPS AND SCREWS (supplied) DETAIL Using full length hanger straps is recommended for vibration control, but can be shorter if required. Vertical Installation Wall Mounting the HRV "L" BRACKETS (not included) may be installed if wall Suspending the RNC120D mounting is desired for the vertical installation. The hanging straps s

Summary of the content on the page No. 15

Drain Connections Drain Connection (HRV Only) "P" Trap (HRV only) During a defrost cycle, the HRV may produce some DRAIN HOSE PLUMBING condensation. This water should flow into a nearby drain, or be PRE-PUNCHED HOLES (2) taken away by a condensate pump. DRAIN PAN DRAIN PAN CAUTION DRAIN DRAIN SPOUT SPOUT The HRV and all condensate lines must be installed in a space where the temperature is ZIP TIE TEE 1/2 " I.D. CONNECTOR maintained above the freezing point or freeze DRAIN HOSE protection

Summary of the content on the page No. 16

Installation Methods The Three Methods of Installation Air Duct Design and Installation The three methods of installation for the HRV system are the A well designed and installed ducting system will allow the Simplified, Partially Dedicated and Fully Dedicated HRV to operate at its maximum efficiency. Installations. Refer to the installation illustrations in this manual. Always try to keep duct runs as short and straight as possible. See Installation Diagrams for various installation options. S

Summary of the content on the page No. 17

The Simplified Installation (Return/Return Method) It is mandatory that the furnace run continuously or HRV • operation be interlocked with the furnace. WARNING Check local codes/authority having jurisdiction for  HRV must be balanced. acceptance. Refer to “Airflow Balancing” in this manual. FOUR PORT MODELS DIRECT CONNECTION of both the HRV SUPPLY AIR STREAM and EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN RETURN AIR 40" (1m) MINIMUM 3' (1 m) min. recommended Outdoors Cool Air Re

Summary of the content on the page No. 18

The Partially Dedicated Installation Stale air drawn from key areas of home  WARNING (bathroom, kitchen, laundry) Fresh air supplied to return air duct of air handler HRV must be balanced.  Refer to “Airflow Balancing” in this manual. FOUR PORT MODELS DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN (Stale air drawn from key areas of home) EXHAUST AIR from various parts of home. i.e. bathrooms (if required), kitchens (if required). Return Air 3' (1 m) min . Outdo

Summary of the content on the page No. 19

The Fully Dedicated Installation Stale air drawn from key areas of home  WARNING (bathroom, kitchen, laundry) Fresh air supplied to main living areas of house HRV must be balanced.  Refer to “Airflow Balancing” in this manual. FOUR PORT MODELS - Models RNC155/RNC200 Fresh air to house - main living areas... bedrooms, living room, Stale Air from various rec. room etc. parts of home. i.e. bathrooms (if required) kitchens (if required) Outdoors *Unit is normally balanced on HIGH speed wi

Summary of the content on the page No. 20

Grilles and Weatherhoods Lifebreath Grilles REMOVABLE Adjustable grilles should be used to balance the flow rates into and out of Kitchen Grille FILTER various rooms. 6” x 10” Kitchen Grille Part No. 10-002 Grilles or diffusers should be positioned high on the wall or in the ceiling. Kitchen exhaust grilles must never be connected to a range hood. They Replacement Grease Filter should be installed at least 4 feet (1.2m) horizontally away from the stove. Part No. 10-002-2 This grille includes a r


Alternative user manuals
# User manual Category Download
1 Lifebreath 100 FN User manual Ventilation Hood 3
2 Lifebreath 2500EFD User manual Ventilation Hood 0
3 Lifebreath 300TRV User manual Ventilation Hood 2
4 Lifebreath 195TRV User manual Ventilation Hood 2
5 Lifebreath 120ERV User manual Ventilation Hood 2
6 Lifebreath 300DCS User manual Ventilation Hood 2
7 Lifebreath 195DCS User manual Ventilation Hood 0
8 Lifebreath 2500IFD User manual Ventilation Hood 0
9 Lifebreath 94-EXCHANGER User manual Ventilation Hood 5
10 Lifebreath 99-129 User manual Ventilation Hood 1
11 Lifebreath Indoor Air Systems2500IFD User manual Ventilation Hood 0
12 Lifebreath 94-EXCHANGER-MD User manual Ventilation Hood 0
13 Lifebreath 99-MD-KIT User manual Ventilation Hood 0
14 Lifebreath Clean Air Furnace CAF-02-MB User manual Ventilation Hood 1
15 Lifebreath RNC120F User manual Ventilation Hood 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0