Kuppersbusch USA IKD 12250.0 user manual

User manual for the device Kuppersbusch USA IKD 12250.0

Device: Kuppersbusch USA IKD 12250.0
Category: Ventilation Hood
Manufacturer: Kuppersbusch USA
Size: 0.79 MB
Added : 10/11/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kuppersbusch USA IKD 12250.0. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kuppersbusch USA IKD 12250.0.

For your convenience

If looking through the Kuppersbusch USA IKD 12250.0 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kuppersbusch USA IKD 12250.0 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kuppersbusch USA IKD 12250.0 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kuppersbusch USA IKD 12250.0 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kuppersbusch USA IKD 12250.0 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kuppersbusch USA IKD 12250.0. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GB Instructions Booklet
FR Mode d’emploi
IKD 12250.0

Summary of the content on the page No. 2

Summary of the content on the page No. 3

READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local electrical inspectors’ use. READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always tur

Summary of the content on the page No. 4

WARNING  Venting system MUST terminate outside the home.  DO NOT terminate the ductwork in an attic or other enclosed space.  DO NOT use 4" laundry-type wall caps.  Flexible-type ductwork is not recommended.  DO NOT obstruct the flow of combustion and ventilation air.  Failure to follow venting requirements may result in a fire. ELECTRICAL REQUIREMENTS A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker is recomme

Summary of the content on the page No. 5

Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers

Summary of the content on the page No. 6

CHARACTERISTICS Dimensions      GB 6             

Summary of the content on the page No. 7

Components Ref. Q.ty Product Components  1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising:  2.1 1 Upper Section  2.2 1 Lower Section  7.1 1 Telescopic frame complete with extractor,  consisting of:  7.1a 1 Upper frame 7.1b 1 Lower frame   8a 1 Right Air Outlet Grill 8b 1 Left Air Outlet Grill  14.1 1 Air Outlet Connection Extension   15 1 Air Outlet Connection 24 1 Junction box  25 2 Pipe clamps   Ref. Q.ty Installa

Summary of the content on the page No. 8

INSTALLATION Drilling the Ceiling/shelf and fixing the frame DRILLING THE CEILING/SHELF • Use a plumb line to mark the centre of the hob on the ceiling/support shelf.  Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template is in the correct position by lining up the axes of the template with those of the hob.  Mark the centres of the holes in the template.  Drill the holes at the points marked:  For concrete ceilings, drill for plugs appropriate t

Summary of the content on the page No. 9

FIXING THE FRAME  Loosen the two screws fastening the lower chimney and remove this from the lower frame.  Loosen the two screws fastening the upper chimney and remove this from the upper frame. If you wish to adjust the height of the frame, proceed as follows:  Unfasten the eight metric screws joining the two columns, located at the sides of the frame.  Adjust the frame to the height required, then replace all the screws removed as above.    Insert the upper chimney stack from above,

Summary of the content on the page No. 10

Flue assembly - Mounting the hood body  Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c (2,9 x 9,5) provided.   Similarly, position the lower chimney section and fix the lower part to the frame using the 2 screws 12c (2,9 x 9,5) provided. Recirculation version  Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets.  If this is not the case, remove the lower chimney section

Summary of the content on the page No. 11

USE Control panel      L Light Switches the lighting system on and off. S Led Motor running led. V1 Motor Switches the extractor motor on and off at low speed. Used to provide a continuous and silent air change in the presence of light cooking vapours. V2 Speed Medium speed, suitable for most operating conditions given the optimum treated air flow/noise level ratio. V3 Speed Maximum speed, used for eliminating the highest cooking vapour emission, including long periods. MAINTENANCE Greas

Summary of the content on the page No. 12

Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER  This filter is not washable and cannot be regen- erated, and must be replaced approximately every four months of operation, or more frequently with heavy usage.  Remove the metal grease filters.  Remove the saturated activated carbon filter by releasing the fixing hooks.  Fit the new filter by hooking it into its seating.  Replace the metal grease filters. Lighting LIGHT REPLACEMENT • 20 W halogen lig

Summary of the content on the page No. 13

LISEZ BIEN CETTE FICHE AVANT D’INSTALLER LA HOTTE AVERTISSEMENT - POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA TABLE DE CUISSON : Ne jamais laisser un élément de la table de cuisson fonctionner sans sur- veillance à la puissance de chauffage maximale; un renversement/déborde-ment de matière graisseuse pourrait provoquer une inflammation et le génération de fumée. Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d’huile. Actionner toujours la hotte quand on f

Summary of the content on the page No. 14

AVERTISSEMENT  Le système d’évacuation DOIT sortir à l’extérieur.  N’ÉVACUEZ PAS le conduit soit dans une mansarde soit dans un espace enfermé.  N’UTILISEZ PAS un clapet de séchoir à 4 pouces.  N’utilisez pas un conduit flexible.  N’ENCOMBREZ PAS la circulation d’air.  Faute de suivre cet avertissement pourrait occasionner un feu. FICHE TECHNIQUE ÉLECTRIQUE Le raccordement électrique doit se faire avec un circuit séparé de 15 ampères fusible à 120V, 60 Hz, courant alternant. On recommande

Summary of the content on the page No. 15

appareils à combustion. Suivez les conseils et mesures de sécurité du fournisseur tels que ceux publiés par l’Association Nationale de la Sauvegarde contre l’Incendie et l’Association Américaine d’Ingénieurs de Chauffage, Frigorifaction et Air Climatisé ainsi que les codes municipaux. En perçant un mur veillez à ne pas perforer un autre fil électrique. Une hotte à évacuation extérieure doit être raccordée à l’extérieur. AVERTISSEMENT  Une prise à terre est nécessaire pout cette hotte.  N’utili

Summary of the content on the page No. 16

CARACTERISTIQUES Encombrement      FR 16             

Summary of the content on the page No. 17

Composants Réf. Q.té Composants de Produit  1 1 Corps Hotte équipé de: Comandes, Lumière, Filtres 2 1 Cheminée Télescopique formée de :  2.1 1 Cheminée Supérieure   2.2 1 Cheminée Inférieure 7.1 1 Treillis télescopique avec Aspirateur, formé par:  7.1a 1 Treillis supérieur  7.1b 1 Treillis inférieur   8a 1 Grille en Direction Droite Sortie Air 8b 1 Grille en Direction Gauche Sortie Air 14.1 1 Rallonge Raccord Sortie Air  15 1 Raccord Sortie Air   24 1 Boîte connexions 2

Summary of the content on the page No. 18

INSTALLATION Perçage Plafond/Étagère et Fixation Treillis PERÇAGE PLAFOND/ÉTAGÈRE  À l’aide d’un Fil à plomb, reporter sur le Plafond/Étagère de support le centre du Plan de Cuisson.  Poser contre le Plafond/Étagère le Gabarit de Perçage 21 fourni avec l’appareil, en faisant coïncider son centre avec le centre projeté et en alignant les axes du Gabarit avec les axes du Plan de Cuisson.  Marquer les centres des Trous du Gabarit.  Percer les trous qui ont été marqués:  Plafond en Béton massif

Summary of the content on the page No. 19

FIXATION TREILLIS  Dévisser les deux vis qui fixent la cheminée inférieure et sortir cette dernière du treillis (depuis la partie inférieure).  Dévisser les deux vis qui fixent la cheminée supérieure et sortir cette dernière du treillis (depuis la partie supérieure). Si l’on souhaite régler la hauteur du treillis, effectuer les opérations suivantes:  Dévisser les huit vis métriques qui unissent les deux co- lonnes, qui se trouvent sur les côtés du treillis.  Régler la hauteur souhaitée du tr

Summary of the content on the page No. 20

Montage Cheminée - Montage Corps Hotte  Positionner la Cheminée supérieure et fixer cette der- nière dans la partie supérieure du Treillis à l’aide de 2 Vis 12c (2,9 x 9,5) fournies avec l’appareil.   De la même façon, positionner la Cheminée inférieure et fixer cette dernière dans la partie inférieure du Treillis à l’aide de 2 Vis 12c (2,9 x 9,5) fournies avec l’appareil. Version Filtrante  S’assurer que la sortie des rallonges raccord 14.1 se trouve au niveau des bouches de la chem


Alternative user manuals
# User manual Category Download
1 Kuppersbusch USA IKD 1157.1 GE-UL User manual Ventilation Hood 12
2 Kuppersbusch USA KD 6500.1 User manual Ventilation Hood 20
3 Kuppersbusch USA Kitchen Hoods User manual Ventilation Hood 7
4 Sony SH-L35W User manual Ventilation Hood 0
5 Air King AIF8X User manual Ventilation Hood 3
6 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
7 Air King AIF10X User manual Ventilation Hood 0
8 Agilent Technologies 31A User manual Ventilation Hood 0
9 Air King 500CFM User manual Ventilation Hood 0
10 Agilent Technologies 6610XA User manual Ventilation Hood 1
11 Air King AIK14X User manual Ventilation Hood 0
12 Agilent Technologies HP 83621A User manual Ventilation Hood 0
13 Air King 380 CFM User manual Ventilation Hood 38
14 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2
15 Air King AD series User manual Ventilation Hood 1