Kobe Range Hoods RA9230SQB user manual

User manual for the device Kobe Range Hoods RA9230SQB

Device: Kobe Range Hoods RA9230SQB
Category: Ventilation Hood
Manufacturer: Kobe Range Hoods
Size: 1.6 MB
Added : 10/11/2013
Number of pages: 68
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kobe Range Hoods RA9230SQB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kobe Range Hoods RA9230SQB.

For your convenience

If looking through the Kobe Range Hoods RA9230SQB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kobe Range Hoods RA9230SQB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kobe Range Hoods RA9230SQB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kobe Range Hoods RA9230SQB User manual - Online PDF
Advertisement
« Page 1 of 68 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kobe Range Hoods RA9230SQB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kobe Range Hoods RA9230SQB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



KOBE Brand Range Hood

os
Model No. / N de modèles / Modelo No.
RA9230SQB
RA9236SQB
RA-092 SERIES – 12" HEIGHT








INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
NOTICE D'INSTALLATION
ET MODE D'EMPLOI
INSTRUCCIONES DE INSTALACIÓN Y
MANUAL DE OPERACIÓN

Summary of the content on the page No. 2

[ENGLISH] ...................................................................................................................... 1 [FRENCH] ..................................................................................................................... 23 [SPANISH] .................................................................................................................... 45 2

Summary of the content on the page No. 3

[ENGLISH] - READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS......................................................................... 2 COMPONENTS OF PACKAGE....................................................................................... 4 INSTALLATION ............................................................................................................... 5 OPERATION INSTRUCTIONS......................................................................

Summary of the content on the page No. 4

IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) Ducted fan

Summary of the content on the page No. 5

What to Do In The Event Of a Range Top Grease Fire � SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. � NEVER PICK UP A BURNING PAN – You May Get Burned. � DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. � Use an extinguisher ONLY if: a) You h

Summary of the content on the page No. 6

COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) Range Hood Box Model No. RA9230SQB (6) Baffle Filter RA9236SQB - 2 (30") (1) KOBE Range Hood – 1 - 3 (36") (2) Warranty Registration Card – 1 (7) Baffle Handle (3) Instructions Manual – 1 - 2 (30") (4) Hood-Mounting Bracket – 2 - 3 (36") (5) Screws Package – 1 (8) Screws Package – 1 (1) (6) (2) (3)

Summary of the content on the page No. 7

INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to TABLE 1. (All calculation in inches.) TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) D = Height of Hood E = Height of the Hood Installation [A – (B+C)] F = Height of Duct Cover [E – D] SAFETY WARNING HOOD MAY

Summary of the content on the page No. 8

Preparation before Installation Figure 1 NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. (Figure 1) - A straight, short venting run will allow the hood to perform more efficiently. - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. - Temporarily wire the hood to test for proper Figure 2 operation before installi

Summary of the content on the page No. 9

4. Secure and tighten the mounting screws. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING. Figure 5 Ductwork Installation 5. Using Reference E from Table 1 and measurements on Page 13, mark the leveling point for duct cover-mounting bracket. 6. Secure the duct cover-mounting bracket to the wall with two screws (not provided). (Figure 6) Make sure all screws are tightened. NOTE: Inner duct cover will cover the duct cover-mounting bracket. 7. Use aluminum or steel pipe (

Summary of the content on the page No. 10

inner duct cover with two (4x8 mm) screws (provided). 12. Fasten outer duct cover to plastic plate on Figure 9 the hood with four (4x8 mm) screws (provided). Install Accessories 13. Place baffle filters underneath the hood. Refer to Figure 10. Final Assembly 14. Turn power ON in control panel. Check all lights and fan operation. 15. Leave this Installation Instructions and Operation Manual for the homeowner. Figure 10 8

Summary of the content on the page No. 11

OPERATION INSTRUCTIONS This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30- second delay shutoff, double horizontal squirrel cage with baffle filters, and two bright 12-volt 20-watt halogen lights. The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control (On/Off). Refer to Figure 11.

Summary of the content on the page No. 12

MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. Cleaning Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. DO NOT USE PAPER TOWEL ON STAINLESS STEEL. For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly. *** Regular care will help preserve the appearance of the hood. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks spl

Summary of the content on the page No. 13

To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. NOTE: DO NOT TOUCH HALOGEN LIGHT WITH BARE HANDS, WHICH MIGHT CAUSE OVER HEAT AND SHORTEN THE LIFT OF LIGHT BULBS.     1. Make sure all controls are OFF, and range hood is unplugged. 2. Place the flat-head screwdriver into the groove between the halogen light glass covering and the

Summary of the content on the page No. 14

SPECIFICATIONS MODEL / SIZE RA9230SQB / 30" RA9236SQB / 36" COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE RA9230SQB - 215W / 1.79A RA9236SQB - 215W / 1.79A VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 DESIGN 18-Gauge Seamless / Satin Finish FAN TYPE Double Horizontal Squirrel Cage EXHAUST Top 6" Round CONTROLS Electronic Control (4 Buttons) – 10-Second Standby Startup 30-Second Delay Shutoff HALOGEN LIGHTS RA9230SQB - 12V 20W x 2 RA9236SQB - 12V 20W x 2 HOO

Summary of the content on the page No. 15

MEASUREMENTS & DIAGRAMS  All ( ) are in millimeter.  All inch measurements are converted from millimeters. Inch measurements are estimated. Front View Bottom View 13

Summary of the content on the page No. 16

PARTS LIST MODEL NO.: RA9230SQB RA9236SQB NO. DESCRIPTION MODEL / PART NO. SIZE 1 Duct Cover-Mounting Bracket C1-0203-0092 2 Duct Cover RA9236DC B102-0192 3 Plastic Plate C1-0506-0092 4 6" Round Plastic Exhaust C1-0505-0001 5 Hood-Mounting Bracket C1-0221-0001 6 Rubber Stand C1-0510-0101 7 Hood Casing RA9230SQB RA-2530-A RA9236SQB RA-25900-A 8 Halogen Lights (12V 20W) C1-0403-0001 9 Control Panel C1-0404-4110-B 10 Control Panel Bracket C11-0207-5300-A 11 Air Chambe

Summary of the content on the page No. 17

MODEL NO.: RA9230SQB RA9236SQB 15

Summary of the content on the page No. 18

CIRCUIT DIAGRAM MODEL NO.: RA9230SQB RA9236SQB 16

Summary of the content on the page No. 19

TROUBLE SHOOTING Issue Possible Cause Solution After Installation, The power is not on. Make sure the circuit breaker and the unit’s power is both motors and ON. Use a voltage meter to check the power supply. lights are not The wire connection is not secure. Check and tighten wire connection. working. The control panel and processor board Check wire continuity from control panel to processor wiring are disconnected. board. The motor transformer is defective. Check the power input and

Summary of the content on the page No. 20

DISCLAIMER 1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM. Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with necessary forms for filing a claim.


Alternative user manuals
# User manual Category Download
1 Kobe Range Hoods CH-100 CH0036SQB User manual Ventilation Hood 1
2 Kobe Range Hoods CH0130SQB User manual Ventilation Hood 0
3 Kobe Range Hoods CH0030SQB (30") User manual Ventilation Hood 0
4 Kobe Range Hoods CH0130SQB (30") User manual Ventilation Hood 0
5 Kobe Range Hoods CH-100 CH0048SQB User manual Ventilation Hood 0
6 Kobe Range Hoods CH-191 User manual Ventilation Hood 0
7 Kobe Range Hoods CH0142SQB User manual Ventilation Hood 0
8 Kobe Range Hoods CH-100 CH0042SQB User manual Ventilation Hood 0
9 Kobe Range Hoods CH0136SQB User manual Ventilation Hood 0
10 Kobe Range Hoods CH2748SQB User manual Ventilation Hood 0
11 Kobe Range Hoods CH2236SQ User manual Ventilation Hood 0
12 Kobe Range Hoods CH2230SQ User manual Ventilation Hood 0
13 Kobe Range Hoods CH2730SQB User manual Ventilation Hood 0
14 Kobe Range Hoods CH7636SQB User manual Ventilation Hood 0
15 Kobe Range Hoods CH2736SQB User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0