Summary of the content on the page No. 1
KOBE Brand Range Hood
Model No. CH7630SQB (30”)
CH7636SQB (36”)
CH7642SQB (42”)
CH7648SQB (48”)
CH-176 SERIES – 10” HEIGHT
INSTALLATION INSTRUCTI
Summary of the content on the page No. 2
- READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS .........................................................................1 COMPONENTS OF PACKAGE.......................................................................................3 INSTALLATION................................................................................................................4 UNDER THE CABINET INSTALLATION ............................................................
Summary of the content on the page No. 3
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) D
Summary of the content on the page No. 4
What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. • NEVER PICK UP A BURNING PAN – You May Get Burned. • DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. • Use an extinguisher ONLY if: a) You
Summary of the content on the page No. 5
COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) Range Hood Box Duct Cover Box (Sold Separately) {A} KOBE Range Hood {I} KOBE Duct Cover {B} Warranty Registration Card (Model No. CH1120DC) {C} Instruction Manual {J} Inner Duct Cover-Mounting Bracket {D} Baffle Filter {K} Outer Duct Cover-Mounting Bracket -- 2 (30”, 36”, 42”) {L} Screws Package -- 3 (48”) {E} Stainless Steel Spacer {I} -- 0 (30”) -- 1 (36”) Inner
Summary of the content on the page No. 6
INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to TABLE 1 or TABLE 2. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) D = Height of Hood E = Height of the Cabinet - FOR STAND ALONE (WITH OPTIO
Summary of the content on the page No. 7
SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Contents UNDER THE CABINET INSTALLATION ........................................................................6 PREPARATION BEFORE INSTALLATION ................................................................
Summary of the content on the page No. 8
UNDER THE CABINET INSTALLATION Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, Figure 1 PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. • Tem
Summary of the content on the page No. 9
4. Draw electrical wires through cabinet Figure 4 access opening. 5. From inside of the hood, place screw (not provided) into the exact center of each knockout hole and secure to cabinet bottom. Once all mounting screws are in place, finish tightening screws until secure. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING. 6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation,
Summary of the content on the page No. 10
Figure 7 Accessories 9. Drop oil tunnel into recess support near rear of hood. Refer to Figure 6. 10. Install baffle filters and stainless spacer(s). Refer to Measurements and Diagrams on page 22 for baffle filter and stainless spacer placement. Angle baffle filter toward back of hood . Push baffle filter up until almost level . Slide forward into recess behind the front of hood . Lower baffle filter . Slide back until it fits into resting
Summary of the content on the page No. 11
STAND ALONE INSTALLATION *** This installation only applies if installing with the CH1120DC duct cover. Figure 8 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. (Figure 8) • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long run as possibl
Summary of the content on the page No. 12
1. Using references in TABLE 1 and Figure 12 Measurements and Diagrams on pages 19-21, mark the leveling point of the hood. Position two mounting screws (not provided) on the wall, leaving 1/8” space away from the wall. 2. Puncture the knockout wire access hole at the back of the hood and draw the electrical wires through as shown in Figure 12. 3. Align hood-mounting bracket to the screws on the wall and hook hood into place as shown in Figure 13. Tighten sc
Summary of the content on the page No. 13
Duct Cover Installation Figure 15 6. Mark the position of the inner duct cover- mounting bracket {J} (provided). Use reference E from TABLE 2 and Measurements and Diagrams on page 20-21. Attach and secure inner duct cover-mounting bracket {J} with two screws (not provided) to the wall. Refer to Figure 15. NOTE: Inner duct cover will be attached to the mounting bracket. 7. Use 7” round steel pipe (follow building codes in your area) to connect the round exhaust on
Summary of the content on the page No. 14
Figure 19 Final Assembly 14. Turn power ON in control panel. Check all light and fan operation. 15. Make sure to leave this manual for the homeowner. 12
Summary of the content on the page No. 15
OPERATION INSTRUCTIONS This KOBE hood is equipped with six electronic controls, two powerful centrifugal squirrel cages with stainless steel oil tunnel, stainless steel baffle filters and spacer(s), and bright 12- volt 20-watt halogen lights (2 for 30” & 36” and 3 for 42” & 48”). The six electronic buttons control the Light, Speed (QuietMode™, Low, Medium & High) and Power (On/Off). The Power Control offers a 10-second delay startup, 3-minute delay shutoff or immediate shutoff.
Summary of the content on the page No. 16
Figure 21 Turning Fan OFF: The 3-Minute Delay function will only turn off fans. The light settings will not be affected by the delay function. 3-Minute Delay - Press Power Control (On/Off) button once, the LED light for the active speed will flash and fans will shut off after 3 minutes. - During this 3-minute delay, changing speeds will not affect the 3 minute countdown. Immediate Shutoff - Press Power Control (On/Off) button twice, the fans will
Summary of the content on the page No. 17
MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve the appearance of the hood. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel ho
Summary of the content on the page No. 18
To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. 1. Make sure all controls are off, and range hood is unplugged. 2. Place a flat-head screwdriver between light cover and housing to remove cover . 3. Gently pull defective bulb straight out and discard. Light bulbs should
Summary of the content on the page No. 19
SPECIFICATIONS MODEL / SIZE CH7630SQB / 30” CH7636SQB / 36" CH7642SQB / 42” CH7648SQB / 48” COLOR #304 Commercial Grade Stainless Steel CONSUMPTION / AMPERE CH7630SQB – 300W / 3A CH7636SQB – 300W / 3A CH7642SQB – 300W / 3A CH7648SQB – 300W / 3A VOLTAGE 120V 60Hz NUMBER OF MOTORS 2 DESIGN Seamless / Satin Finish MOTOR TYPE Vertical Squirrel Cage EXHAUST Top 7” Round CONTROLS Six Electronic Buttons HALOGEN LIGHTS CH7630SQB - 12V 20W x 2 CH7636SQB - 12V
Summary of the content on the page No. 20
MEASUREMENTS & DIAGRAMS All ( ) are in millimeter. All inch measurements are converted from millimeters. Inch measurements are estimated. - FOR UNDER THE CABINET - MODEL NO: CH7630SQB CH7636SQB CH7642SQB CH7648SQB 18