Kobe Range Hoods CH-100 CH0042SQB user manual

User manual for the device Kobe Range Hoods CH-100 CH0042SQB

Device: Kobe Range Hoods CH-100 CH0042SQB
Category: Ventilation Hood
Manufacturer: Kobe Range Hoods
Size: 2.29 MB
Added : 3/15/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kobe Range Hoods CH-100 CH0042SQB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kobe Range Hoods CH-100 CH0042SQB.

For your convenience

If looking through the Kobe Range Hoods CH-100 CH0042SQB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kobe Range Hoods CH-100 CH0042SQB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kobe Range Hoods CH-100 CH0042SQB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kobe Range Hoods CH-100 CH0042SQB User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kobe Range Hoods CH-100 CH0042SQB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kobe Range Hoods CH-100 CH0042SQB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




KOBE Brand Range Hood


Model No.: CH0030SQB (30'')
CH0036SQB (36'')
CH0042SQB (42'')
CH0048SQB (48'')

CH-100 SERIES – 18'' HEIGHT

INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL

Summary of the content on the page No. 2

{THIS PAGE LEFT PURPOSELY BLANK}

Summary of the content on the page No. 3

- READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS.................................................................................... 4 COMPONENTS OF PACKAGE ................................................................................................. 3 INSTALLATION ......................................................................................................................... 4 UNDER THE CABINET INSTALLATION ..............................

Summary of the content on the page No. 4

IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) D

Summary of the content on the page No. 5

What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. • NEVER PICK UP A BURNING PAN – You May Get Burned. • DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. • Use an extinguisher ONLY if:

Summary of the content on the page No. 6

COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) RANGE HOOD BOX KOBE Range Hood – 1 Warranty Registration Card –1 Instructions Manual – 1 Baffle Filter - 2 (30”, 36”, 42”) - 3 (48”) Stainless Steel Spacer - 2 (30”) DUCT COVER KIT (Sold Separately) - 2 (36”) - 3 (42”) Option Of: - 2 (48”) Oil Tunnel – 1 Model No. CH0030DC-12 for 30'' hood KOBE Duct Cover – 1 Ducting

Summary of the content on the page No. 7

INSTALLATION PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to Table 1. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Height of Counter Top to Hood Bottom (Recommended 27'' to 30'') [(A – B) – (D + E)] D = Height of Hood E = Height of the Cabinet - FOR WALL MOUNT (WITH OPTIONAL DUC

Summary of the content on the page No. 8

SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: USING ELECTRICAL SCREWDRIVERS MAY CAUSE DAMAGE TO THE HOOD. Installation Table of Contents UNDER THE CABINET INSTALLATION................................................................................6 Preparation Before Installation................................................................................................6 Hood Inst

Summary of the content on the page No. 9

UNDER THE CABINET INSTALLATION Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance Figure 1 of the hood. • Temporari

Summary of the content on the page No. 10

Ductwork Installation 8. Use 8” round steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 5. Wiring to Power Supply S AF E T Y W AR N I N G RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD Figure 5 MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL

Summary of the content on the page No. 11

14. Turn power ON in control panel. Check all lights and fan operation. 15. Make sure to leave this manual for the homeowner Figure 8 8

Summary of the content on the page No. 12

WALL MOUNT INSTALLATION ***Follow these installations only if installing with an optional duct cover: Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 9. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long

Summary of the content on the page No. 13

mark the leveling point of the hood. Position two mounting screws (not included) on the wall, leaving 1/8” away from the wall. Refer to Figure 13 WALL 2. Align hood-mounting bracket to the two screws on the wall and hook hood into place. Tighten screws to secure hood to the wall. 3. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws

Summary of the content on the page No. 14

Duct Cover Installation 5. Use 8” round steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer Figure 15. Slide the duct cover onto the hood. 6. Use 3/16” x 3/8” screws (included) to attach duct cover to hood. Figure 15 Final Assembly CAUTION: Install heating lamps last. 7. Drop oil tunnel into recess

Summary of the content on the page No. 15

OPERATING INSTRUCTIONS This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30- second delay shutoff, powerful centrifugal squirrel cage with baffle filters, bright 12-volt 20-watt halogen lights, and heating lamp sockets (lamps not included). The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control (On/Off). Refer to Figure 18.

Summary of the content on the page No. 16

MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve the appearance of the hood. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hood

Summary of the content on the page No. 17

To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.             1. Make sure all controls are off, and range hood is unplugged. 2. Place a flat-head screwdriver between light cover and housing  to remove cover . 3. Gently pull defective bulb straight out  and discard. Light bulbs should be 12

Summary of the content on the page No. 18

SPECIFICATIONS MODEL / SIZE CH0030SQB / 30” CH0036SQB / 36” CH0042SQB / 42” CH0048SQB / 48” DESIGN 18-Gauge Seamless Commercial Stainless Steel CONSUMPTION / AMPERE 702W / 5.85A – 30”, 36” 722W / 6.02A – 42”, 48” VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 FAN TYPE: CENTRIFUGAL Squirrel Cage EXHAUST Top Transition Rectangular to 8” Round x 1 CONTROLS Electronic Control (4 Buttons) – 10-Second Standby Startup 3-Minute Delay Shutoff HALOGEN LIGHTS 30” / 36” - 12V20W x 2

Summary of the content on the page No. 19

MEASUREMENTS & DIAGRAMS All ( ) are in millimeter. All inch measurements are converted from millimeters. Inch measurements are estimated. - FOR UNDER THE CABINET - MODEL NO: CH0030SQB CH0036SQB CH0042SQB CH0048SQB 16

Summary of the content on the page No. 20

- FOR UNDER THE CABINET – (Cont.) 17


Alternative user manuals
# User manual Category Download
1 Kobe Range Hoods CH-100 CH0036SQB User manual Ventilation Hood 1
2 Kobe Range Hoods CH0130SQB User manual Ventilation Hood 0
3 Kobe Range Hoods CH0030SQB (30") User manual Ventilation Hood 0
4 Kobe Range Hoods CH0130SQB (30") User manual Ventilation Hood 0
5 Kobe Range Hoods CH-100 CH0048SQB User manual Ventilation Hood 0
6 Kobe Range Hoods CH-191 User manual Ventilation Hood 0
7 Kobe Range Hoods CH0142SQB User manual Ventilation Hood 0
8 Kobe Range Hoods CH0136SQB User manual Ventilation Hood 0
9 Kobe Range Hoods CH2748SQB User manual Ventilation Hood 0
10 Kobe Range Hoods CH2236SQ User manual Ventilation Hood 0
11 Kobe Range Hoods CH2230SQ User manual Ventilation Hood 0
12 Kobe Range Hoods CH2730SQB User manual Ventilation Hood 0
13 Kobe Range Hoods CH7636SQB User manual Ventilation Hood 0
14 Kobe Range Hoods CH2736SQB User manual Ventilation Hood 0
15 Kobe Range Hoods CH7630SQB User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0