Summary of the content on the page No. 1
KOBE Brand Range Hood
Model No.: CH0130SQB
CH0136SQB
CH0142SQB
CH0148SQB
CH-101 SERIES – 18” HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
Summary of the content on the page No. 2
Summary of the content on the page No. 3
- READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS.................................................................................... 1 COMPONENTS OF PACKAGE ................................................................................................. 3 INSTALLATION ......................................................................................................................... 4 UNDER THE CABINET INSTALLATION ..............................
Summary of the content on the page No. 4
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) Duc
Summary of the content on the page No. 5
What to Do In The Event Of a Range Top Grease Fire - SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. - NEVER PICK UP A BURNING PAN – You May Get Burned. - DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. - Use an extinguisher ONLY if: 1) Yo
Summary of the content on the page No. 6
COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) RANGE HOOD BOX KOBE Range Hood – 1 Warranty Registration Card –1 Instructions Manual – 1 Baffle Filter - 2 (30”, 36”, 42”) - 3 (48”) Stainless Steel Spacer - 0 (30”) - 1 (36”) - 2 (42”, 48”) 3/16" X 3/8" (8 pc) Oil Tunnel – 1 Ducting Transition – 1 DUCT COVER KIT (Sold Separately) Screw Package
Summary of the content on the page No. 7
INSTALLATION PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to Table 1. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) [(A – B) – (D + E)] D = Height of Hood E = Height of the Cabinet - FOR STAND ALONE (
Summary of the content on the page No. 8
SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: USING ELECTRICAL SCREWDRIVERS MAY CAUSE DAMAGE TO THE HOODS. Installation Table of Contents UNDER THE CABINET INSTALLATION................................................................................6 Preparation Before Installation................................................................................................6 Hood
Summary of the content on the page No. 9
UNDER THE CABINET INSTALLATION Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long runs Figure 1 as possible. This may reduce the performance of the hood. • Tempo
Summary of the content on the page No. 10
Ductwork Installation 7. Use 8” aluminum or steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to seal and secure joints as shown in Figure 5. Wiring to Power Supply S AF E T Y W AR N I N G TO PREVENT THE RISK OF ELECTRICAL SHOCK OR Figure 5 INJURY, ALL RANGE HOODS SHOULD BE PROPERLY GROUNDED AND INSTALLED BY A TRAINED PROFESSIONAL WHO IS KNOWLEDGEABLE ABOUT AP
Summary of the content on the page No. 11
15. Install heating lamps (not provided), 120 Volts 250 Watts max. each. 16. Turn power ON in control panel. Check all lights and fan operation. 17. Make sure to leave this manual for the homeowner Figure 8 8
Summary of the content on the page No. 12
STAND ALONE INSTALLATION ***Follow these installations only if installing with an optional duct cover: Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 9. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long
Summary of the content on the page No. 13
2. Align hood-mounting bracket to the two screws WALL on the wall and hook hood into place. Tighten screws to secure hood to the wall. 3. For safety purpose, extra knockout holes on the back of the hood are provided for a more secure installation. Knock out as many holes as needed and secure with screws (not provided) from the inside of hood. CAUTION: MAKE SURE HOOD IS SECURE BEFORE RELEASING. Figure 13 Wiring to Power Supply SA
Summary of the content on the page No. 14
Duct Cover Installation 5. Use 8” aluminum or steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to seal and secure joints as shown in Figure 15. Slide the duct cover onto the hood. 6. Use 3/16” x 3/8” screws (provided) to attach duct cover to hood. Figure 15 Final Assembly CAUTION: Install heating lamps last. 7. Drop Oil Tunnel into suppo
Summary of the content on the page No. 15
OPERATING INSTRUCTIONS This KOBE hood is equipped with touch-sensor screen and features 3 minute delay shutoff, powerful centrifugal squirrel cage with baffle filters, bright 12-volt 20-watt halogen lights and heating lamp capability (heating lamps not included). The touch-sensor screen has Heat Lamp Control, Light Control, Speed Control (QuietMode™, Low, Medium and High), and Power Control. Refer to Figure 18. Heat Lamp Light Control Speed Control Power Control
Summary of the content on the page No. 16
Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control sign once, the symbol flashes and after 3 minutes, the hood will turn off leaving only the sign lit. Speed Control: • There are four speeds: QuietMode™, Low, Medium, and High. To activate the speed, touch the control under the speed sign. For example, if turning on hood at low speed, gently touch the symbol under the sign. If you want to switch from low to high speed, touch the symbol under the sign and
Summary of the content on the page No. 17
MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For optimal operation, clean range hood surface and stainless steel baffle filters regularly. Cleaning Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. Regular care will help preserve the appearance of the hood. 1) Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2) If hood looks splotchy (stainless steel hood), use an or
Summary of the content on the page No. 18
Cleaning Stainless Oil Tunnel, Baffle Filters and Spacers CAUTION: DRAIN OIL BEFORE RESIDUE CAN OVERFLOW. 1. Remove the baffle filter (reverse the order of baffle installation). 2. Carefully remove oil tunnel. 3. Discard oil and residue. 4. Wash oil tunnel, baffle filters and spacers with warm soapy water. 5. Dry thoroughly and put back. NOTE: Oil Tunnel, baffle filters and spacers are top rack dishwasher safe. Replacing Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY B
Summary of the content on the page No. 19
SPECIFICATIONS MODEL / SIZE CH0130SQB / 30“ CH0136SQB / 36“ CH0142SQB / 42“ CH0148SQB / 48“ COLOR #304 Commercial Grade Stainless Steel CONSUMPTION / AMPERE 900W / 8A VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 DESIGN 18 Gauge Seamless / Satin Finish FAN TYPE: CENTRIFUGAL Squirrel Cage EXHAUST Top Transition Rectangular to 8” Round x 1 CONTROLS Touch Sensor Screen HALOGEN LIGHTS 30” / 36” /42” - 12V20W x 2 48” - 12V20W x 3 HEATING LAMPS 120V 250W Max. x 2 (Light Bulbs Not Included)
Summary of the content on the page No. 20
8" (203) 2 - 1/8" (54) 1 - 7/8" (48) 1/ " (12 2 ) 1 - 1/4" (32) 6 - 1/2" (166) 4 - 1/2" (114) 1" (25) 12" (305) 24" (610) MEASUREMENTS & DIAGRAMS *** Inch measurements converted from millimeter. Inch measurements are estimated. - FOR UNDER THE CABINET - MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 17 6 - 1/2" (165) 1 - 1/4"(32) 1 " ) 1 - /4 (32 12" (306) 1 - 1/4" (32) 3 " 36 4 " / 48" 0 / " / 2 18" (457) 3 - 1/8" (79.5)