KitchenAid W10029780 user manual

User manual for the device KitchenAid W10029780

Device: KitchenAid W10029780
Category: Ventilation Hood
Manufacturer: KitchenAid
Size: 0.91 MB
Added : 3/15/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KitchenAid W10029780. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KitchenAid W10029780.

For your convenience

If looking through the KitchenAid W10029780 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KitchenAid W10029780 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KitchenAid W10029780 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KitchenAid W10029780 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KitchenAid W10029780 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KitchenAid W10029780. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

30" (76.2 CM) AND 36" (91.4 CM) WALL-MOUNT
CANOPY RANGE HOOD
Installation Instructions and Use & Care Guide
HOTTE DE CUISINIÈRE POUR MONTAGE
MURAL 30" (76,2 CM) ET 36" (91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY .................................................................3 SÉCURITÉ DE LA HOTTE D’ASPIRATION ................................15 INSTALLATION REQUIREMENTS ................................................4 EXIGENCES D'INSTALLATION...................................................17 Tools and Parts ............................................................................4 Outillage et pièces..........................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON when

Summary of the content on the page No. 4

INSTALLATION REQUIREMENTS T ools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed Have a qualified technician install the range hood. It is the here. installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating Tools needed plate is located inside the ran

Summary of the content on the page No. 5

Non-vented (recirculating) Installations *NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the For non-vented (recirculating) installations, optional Recirculating distance “X” between the bottom of the range hood and the Chimney Kit Part Number 8212713 (Stainless Steel), 8212714 cooking surface. For higher ceilings, a 40" (101.6 cm) Chimney (White), or 8212715 (Black) must be used. These kits include a Extension Kit Part Num

Summary of the content on the page No. 6

Example vent system Venting Methods Wall cap 6 ft (1.8 m) 90 elbow This canopy range hood is factory set for venting through the roof or wall. A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round. 2 ft (0.6 m) NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance. Vent system can terminate either through the roof or wall. To vent The following examp

Summary of the content on the page No. 7

INSTALLATION INSTRUCTIONS Prepare Location ■ It is recommended that the vent system be installed before 2. Mark 2 points on each side of the horizontal line hood is installed. 4⁹⁄₁₆" (11.6 cm) from the vertical centerline. 3. Drill pilot holes. ■ Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent. ■ If installing into wood, drill 2 - ¹⁄₈" (3.2 mm) pilot holes. ■ Check your ceiling height and the hood height maximum ■ If installing into plaste

Summary of the content on the page No. 8

2. Place the other chimney bracket on the wall so that its lower 4. Fit the diverter over the vent motor exhaust outlet and push edge is 16³⁄₁₆" (41.1 cm) from the ceiling or soffit and level. down to seat on outlet. Check that the diverter exhaust outlets are parallel with the vent motor sides so that they will Align the center notches of the bracket and the centerline. align with the vent cover openings in the lower chimney. Mark the centers of the bracket holes. A B A. Diverter 3. Drill

Summary of the content on the page No. 9

Make Electrical Connection WARNING WARNING Fire Hazard Electrically ground the blower. Electrical Shock Hazard Use copper wire. Disconnect power before servicing. Connect ground wire to green ground screw in terminal box. Replace all parts and panels before operating. Failure to do so can result in death, fire, or Failure to do so can result in death or electrical shock. electrical shock. 1. Disconnect power. 8. Connect green (or bare) ground wire from home power supply 2. Remove termina

Summary of the content on the page No. 10

Install Lower Chimney Cover 3. Press the On/Off button (A) to turn the fan on. The speed setting will appear in the display. 1. Slightly spread the sides of the cover apart and hook them behind the upper chimney and the wall. 4. Press the “+” or “-” minus buttons to increase or decrease the fan speed. 2. Attach the cover to the hood with 2 mounting screws. 5. Press the On/Off button (A) to turn off the fan. 3. Securely tighten screws. 6. If range hood does not operate, check to see whether a

Summary of the content on the page No. 11

To Install Charcoal Filter Reset Filter Alert 1. Turn fan and lights off. Check that halogen lamp is cool. 2. Remove the metal grease filters. See “Metal Grease Filters” After 100 hours of use, “C” will appear in the range hood display. section. This “C” indicates that the filter must be cleaned.”C” will only 3. Set metal grease filters aside. appear when turning off the range hood fan. 4. Place charcoal filter into opening. Press back and up on fixing Reset Alarm Display hooks to secure fil

Summary of the content on the page No. 12

WIRING DIAGRAM 12

Summary of the content on the page No. 13

ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your Accessories List appliance. This information will help us to better respond to your request. Charcoal Filter Kit (for non-vented installations only) If you need replacement parts Order Part Number 8285507 If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit Recirculating Chimne

Summary of the content on the page No. 14

WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. This limited warranty

Summary of the content on the page No. 15

SÉCURITÉ DE LA HOTTE D’ASPIRATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte

Summary of the content on the page No. 16

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 17

EXIGENCES D'INSTALLATION Outillage et pièces Exigences d'emplacement Rassembler les outils et pièces nécessaires avant de commencer IMPORTANT : Observer les dispositions de tous les codes et l'installation. Lire et suivre les instructions fournies avec les outils règlements en vigueur. indiqués ici. Confier l'installation de la hotte à un technicien qualifié. C'est à l'installateur qu'incombe la responsabilité de respecter les Outils nécessaires distances de séparation spécifiées sur la plaqu

Summary of the content on the page No. 18

Installations sans décharge à l'extérieur (recyclage) *REMARQUE : La cheminée de la hotte est réglable; on peut l'ajuster en fonction de la hauteur disponible sous plafond ou Pour les installations sans décharge à l'extérieur (recyclage), le kit soffite, et selon la distance “X” entre le bas de la hotte et la de cheminée facultatif pour recyclage, pièce n° 8212713 (acier surface de cuisson. Pour des hauteurs sous plafond plus inoxydable), 8212714 (blanc), ou 8212715 (noir) doit être utilis

Summary of the content on the page No. 19

Air d'appoint Calcul de la longueur effective du circuit d'évacuation Le code du bâtiment local peut exiger l'emploi d'un système d'appoint d'air lors de l'emploi d'un ventilateur d'extraction dont Pour calculer la longueur effective du circuit d'évacuation la capacité d'aspiration est supérieure à un débit (pieds cubes nécessaire, additionner les longueurs équivalentes (pieds/mètres) par minute) spécifié. Le débit spécifié, pieds cubes par minute, de tous les composants utilisés dans le s

Summary of the content on the page No. 20

■ L'appareil doit être alimenté par un circuit de 120 V, CA ■ Le calibre des conducteurs et les connexions doivent être seulement, 60 Hz, 15 ampères, protégé par fusible. compatibles avec la demande de courant de l'appareil spécifiée sur la plaque signalétique. La plaque signalétique ■ Si le domicile est équipé d'un câblage en aluminium, suivre de l'appareil est située derrière le filtre, sur la paroi arrière de les instructions suivantes : la hotte. 1. Connecter une section de câble en cui


Alternative user manuals
# User manual Category Download
1 KitchenAid 30 User manual Ventilation Hood 4
2 KitchenAid 36"(91.4CM) ISLAND RANGE HOOD User manual Ventilation Hood 6
3 KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood User manual Ventilation Hood 4
4 KitchenAid 36 User manual Ventilation Hood 1
5 KitchenAid 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) Wall-Mount Canopy Range Hood User manual Ventilation Hood 7
6 KitchenAid 4329223 User manual Ventilation Hood 1
7 KitchenAid 4360369 User manual Ventilation Hood 1
8 KitchenAid 30" and 36" Retractable Downdraft Vent Systems User manual Ventilation Hood 7
9 KitchenAid 6899551 User manual Ventilation Hood 1
10 KitchenAid 48 User manual Ventilation Hood 1
11 KitchenAid 883297 User manual Ventilation Hood 1
12 KitchenAid 883298 User manual Ventilation Hood 2
13 KitchenAid 42 User manual Ventilation Hood 0
14 KitchenAid 6899552 User manual Ventilation Hood 1
15 KitchenAid 9763388 User manual Ventilation Hood 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0