KitchenAid KPEU722M user manual

User manual for the device KitchenAid KPEU722M

Device: KitchenAid KPEU722M
Category: Ventilation Hood
Manufacturer: KitchenAid
Size: 0.69 MB
Added : 2/20/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KitchenAid KPEU722M. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KitchenAid KPEU722M.

For your convenience

If looking through the KitchenAid KPEU722M user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KitchenAid KPEU722M on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KitchenAid KPEU722M to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KitchenAid KPEU722M User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KitchenAid KPEU722M but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KitchenAid KPEU722M. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation Instructions and
Use and Care Guide
30" (76.2 cm)
36" (91.4 cm)
Retractable (Pop-up)
Downdraft Vent Systems
Quick Reference
IMPORTANT:
Table of Contents:
Pages
Read and save
2
Before you start
these instructions.
3 Electrical requirements
4
Product dimensions
4 Cabinet dimensions
IMPORTANT:
5 Countertop cutout dimensions
Installer: Leave Installation Instructions with
6 Vent system requirements
the homeowner.
Interior-mounted vent motor
Homeowner: Keep Installation Instructions for

Summary of the content on the page No. 2

Mobile home installation Parts supplied Before you start... The installation of this downdraft vent system must conform to the for installation: Manufactured Home Construction Your safety and the safety of Safety Standards, Title 24 CFR, others are very important. Part 328 (formerly the Federal We have provided many important Standard for Mobile Home safety messages in this manual Construction and Safety, Title 24, and on your appliance. Always HUD, Part 280) or when such read and obey all safe

Summary of the content on the page No. 3

Electrical requirements IMPORTANT: Observe all E. A U.L.- or C.S.A.-listed, 1/2" governing codes and ordinances. C. Wire sizes and connections (12.7 mm) conduit connector must conform to the It is the customer’s responsibility: must be provided at each end of requirements of the National the power supply cable (at the Electrical Code, ANSI/NFPA 70 — • To contact a qualified electrical downdraft vent and at the latest edition*, or CSA Standards installer. junction box). C22.1-94, Canadian Electri

Summary of the content on the page No. 4

Product dimensions top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm) 8-1/4" (21 cm) retractable vent height 4" (10.2 cm) 1-1/2" (3.8 cm) 16" (40.6 cm) 3/8" (9.5 mm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 8" (20.3 cm) 26-1/8" 5/8" (66.4 cm) (15.9 mm) 3-1/4"x 10" 9" (22.9 cm) Dia. (8.3 cm x 25.4 cm) NOTE: A 10" (2.5 cm) round vent 16" system adapter (40.6 cm) 8" collar attaches over (20,3 cm) this hole. Adapter 16" collar is supplied 5/8" (40.6 cm) with ext

Summary of the content on the page No. 5

Countertop cutout dimensions 1-7/8" 27-1/2" (69.9 cm) for 30" (76.2 cm) vent (4.8 cm) Some models require a 33-1/2" (85.1 cm) for 36" (91.4 cm) vent 1/4" countertop deeper than (6.4 mm) 25" (63.5 cm); see cutout dimensions chart below. 1/2" cooktop A = 1/2" (12.7 mm) (12.7 mm) min. min. backsplash countertop See cutout 1/4" dimensions (6.4 mm) chart below. centerline of downdraft cooktop cutout vent 1/2" (12.7 mm) 3/4" (19.1 mm) max. It is recommended that the cooktop minimum backsplash d

Summary of the content on the page No. 6

Interior-mounted vent motor Vent system Vent system installed under a Installation requirements requirements concrete slab using PVC sewer pipe. 6" (15.2 cm) round metal vent Venting system must terminate to 6" (15.2 cm) transition Island location wall round PVC 6" (15.2 cm) the outside. cap sewer pipe round metal vent Do not terminate the vent system 6" (15.2 cm) in an attic or other enclosed area. 12" (30.5 cm) 16" (40.6 cm) round PVC minimum maximum coupling Do not use 4" (10.2 cm) laundry

Summary of the content on the page No. 7

easily assemble the downdraft 6" (15.2 cm) round level vent system. Remove parts vent system packages, downdraft vent and mark 90° elbows 6 ft. (1.8 m) blower box from carton and set on protective surface. Remove all transition shipping materials, tape and protective film from downdraft 2 ft. (0.6 m) vent and blower box. over counter support arm 6. Move support legs down Maximum length = 35 ft. (8.9 m) against cabinet floor. Place a level 1 - wall cap = 0 ft. (0 m) against front of downdraft ven

Summary of the content on the page No. 8

12. Disconnect power. WARNING bracket for rear venting Excessive Weight Hazard green ground Use two or more people to move screw and install downdraft vent. Failure to do so can result in back or other injury. d. Remove screws attaching brackets to each side of blower. 10. Insert downdraft vent Reposition brackets on blower into countertop cutout. Two people as shown. Then reinstall screws. are recommended to support the wiring e. Reinstall blower in blower box box weight of the downdraft vent c

Summary of the content on the page No. 9

16. Turn the control knob on To get the most efficient use 17. Connect vent system to side of vent to check the from your new retractable blower. Vent system must end with operation and speed of blower. a wall or roof cap. Use duct tape to downdraft vent, read the Use seal all joints. If blower does not operate: and Care Information section on page 12. • Check that filter or filters are pressed in as far as they will go. Keep Installation Instructions 18. Install cooktop according and Use an

Summary of the content on the page No. 10

Recommended standard cabinet floor. Align top of legs fittings with pencil marks on face of support leg downdraft vent. Tighten screws in legs. 7. Attach 10" (25.4 cm) round vent collar plate (supplied with exterior blower system) to front of 90° elbow = 45° elbow = 4. Attach support legs to side of 5 ft. (1.5 m) 2.5 ft. (0.8 m) downdraft vent using 4 hex washer downdraft vent with two screws in nuts. each leg. Do not tighten screws. Installation steps 8. Remove the 2 Phillips-head screws attac

Summary of the content on the page No. 11

10. Insert retractable 15. Reconnect power. downdraft vent into countertop cutout. Two people are microswitches behind filters vent box ON/OFF recommended to support the knockout button weight of the downdraft vent wiring box during lifting. Position downdraft cover vent so it is centered in cutout and parallel to edge of cutout. Check green that downdraft vent is vertical. Then green blower ground ground control attach lower support legs to cabinet screw wire knob floor with screws. filter or f

Summary of the content on the page No. 12

Use and Care Information The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. For the best results, the vent should be operating before cooking is started. If you use large or tall utensils, place them on the large rear element or burner surface. A higher heat setting than normally used may be needed when the downdraft vent is operating. WARNING — TO REDUCE THE RISK OF FIRE, Use proper pan size. Always use cookware ELECTRIC SHOCK, OR

Summary of the content on the page No. 13

If retractable downdraft vent does not operate after clean filters Accessories have been reinstalled: available from your dealer Push the filter in as far as it will go. When the filter is removed, NOTE: Instructions are included the microswitch behind the filter with each kit. is inactivated. This safety feature stops the blower and raising mechanism until the filter is For model series For model series properly reinstalled. KIRD & YKIRD 801, 802 GZ & YGZ 7930 30" (76.2 cm) one-piece trim: 30

Summary of the content on the page No. 14

WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or ® furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for FSP replacement parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. ITEMS WHIRLPOOL WILL NOT

Summary of the content on the page No. 15

Requesting Assistance or Service in U.S.A. Identify the brand of your vent system and, as Installation information • appropriate, call the KitchenAid Customer Use and maintenance procedures • Interaction Center toll-free at 1-800-422-1230 or call Accessory and repair parts sales • the Whirlpool Customer Interaction Center toll-free Specialized customer assistance (Spanish • at 1-800-253-1301. Our consultants are available to speaking, hearing impaired, limited vision, etc.) assist you. Referrals

Summary of the content on the page No. 16

NOTES Part No. 4329225/9763381 Printed in Italy. © 2005 Whirlpool Corporation ® Registered trademark/™ trademark of KitchenAid, U.S.A., KitchenAid Canada licensee in Canada 10/2005 16

Summary of the content on the page No. 17

Instructions d’installation et Guide d’utilisation et d’entretien Système rétractable d’aspiration par le bas 76,2 cm (30 po) 91,4 cm (36 po) Référence rapide IMPORTANT : Table des matières : Pages Lire et conserver 2 Avant de commencer... ces instructions. 3 Alimentation électrique 4 Dimensions du produit 4 Dimensions du placard IMPORTANT : 5 Ouverture à découper Installateur : Remettre les instructions d’installation au propriétaire de l’appareil. 6 Système de décharge - Ventilateur intérie

Summary of the content on the page No. 18

Assurer l’étanchéité au niveau de Pièces fournies chaque ouverture découpée dans le Avant de commencer... plancher ou le mur pour l’installation pour l’installation : du système d’aspiration. Votre sécurité et celle des Une liaison électrique entre la terre et autresest très importante. le système est nécessaire. Voir à la Nous donnons de nombreux messages de page 3 “Alimentation électrique” . sécurité importants dans ce manuel, et sur Lors de l’installation du système votre appareil ménager. A

Summary of the content on the page No. 19

Alimentation électrique IMPORTANT : Respecter les prescriptions de tous les codes et E. Un connecteur de conduit de C. Le calibre des conducteurs et règlements en vigueur. 12,7 mm (1/2 po) (homologation UL les connexions doivent satisfaire les ou ACNOR) doit être installé à chaque prescriptions du Code national des C’est au client qu’incombe la extrémité du câble d’alimentation installations électriques ANSI/NFPA responsabilité de : (sur le système d’aspiration et sur la 70 - dernière édition*,

Summary of the content on the page No. 20

Dimensions du produit garniture supérieure pour modèle 76,2 cm (30 po), modèle 91,4 cm (36 po) 21 cm (8 1⁄4 po) hauteur de déploiement/ rétraction 10,2 cm 3,8 cm (4 po) (1 1/2 po) 9,5 mm (3/8 po) 68,6 cm (27 po) pour modèle de 76,2 cm (30 po) 40,6 cm 83,8 cm (33 po) pour modèle de 91,4 cm (36 po) (16 po) 20,3 cm (8 po) 66,4 cm (26 1/8 po) 8,3 cm x 25,4 cm 22,9 cm (9 po) (3 1/4 po x 10 po) 15,9 mm Diamètre (5/8 po) 40,6 cm NOTE : Une (16 po) collerette d'adaptation de 10 20,3 cm po (2,5 cm)


Alternative user manuals
# User manual Category Download
1 KitchenAid KPEU722M User manual Microwave Oven 1
2 KitchenAid 30 User manual Ventilation Hood 4
3 KitchenAid 36"(91.4CM) ISLAND RANGE HOOD User manual Ventilation Hood 6
4 KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood User manual Ventilation Hood 4
5 KitchenAid 36 User manual Ventilation Hood 1
6 KitchenAid 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) Wall-Mount Canopy Range Hood User manual Ventilation Hood 7
7 KitchenAid 4329223 User manual Ventilation Hood 1
8 KitchenAid 4360369 User manual Ventilation Hood 1
9 KitchenAid 30" and 36" Retractable Downdraft Vent Systems User manual Ventilation Hood 7
10 KitchenAid 6899551 User manual Ventilation Hood 1
11 KitchenAid 48 User manual Ventilation Hood 1
12 KitchenAid 883297 User manual Ventilation Hood 1
13 KitchenAid 883298 User manual Ventilation Hood 2
14 KitchenAid 42 User manual Ventilation Hood 0
15 KitchenAid 6899552 User manual Ventilation Hood 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0