KitchenAid 9763382 user manual

User manual for the device KitchenAid 9763382

Device: KitchenAid 9763382
Category: Ventilation Hood
Manufacturer: KitchenAid
Size: 0.58 MB
Added : 4/29/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KitchenAid 9763382. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KitchenAid 9763382.

For your convenience

If looking through the KitchenAid 9763382 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KitchenAid 9763382 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KitchenAid 9763382 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KitchenAid 9763382 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KitchenAid 9763382 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KitchenAid 9763382. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


36" (91.4 cm) PRO-LINE SERIES ISLAND RANGE HOOD
Installation Instructions and Use and Care Guide

HOTTE D'ASPIRATION PRO-LINE DE 36" (91,4 cm)
POUR CUISINE CONFIGURÉE EN ÎLOT
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSI

Summary of the content on the page No. 2

TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE . . . . . . . . . . . . . .16 INSTALLATION REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . .4 EXIGENCES D'INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . .18 Outillage et pièces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Tools and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON w

Summary of the content on the page No. 4

INSTALLATION REQUIREMENTS Product Dimensions Tools and Parts Gather the required tools and parts before starting installation. Read and follow the safety instructions provided with any tools 12¹⁄₁₆" 13³⁄₄" listed here. (30.6 cm) (34.9 cm) Tools needed: ■ level ■ drill with 1¹⁄₄" (3.0 cm) drill bit ■ pilot hole drill bit (determined by chimney support attachment method) ■ pencil 26³⁄₈" (65.1 cm) ■ wire stripper or utility knife min. ■ measuring tape or ruler 39" (99.1cm) ■ pliers max. 23⁵⁄₈"

Summary of the content on the page No. 5

Cold weather installations An additional backdraft damper should be installed to minimize Installation Clearances backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house. Make-up air Local building codes may require the use of make-up air systems when usi

Summary of the content on the page No. 6

Calculating Vent System Length Electrical Requirements To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. WARNING Maximum equivalent vent length is 35 feet (10.7 meters). Vent piece 6" (15.2 cm) round 45° elbow 2.5 feet (0.8 m) Electrical Shock Hazard 90° elbow 5.0 feet Disconnect power before servicing. (1.5 m) Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. wall cap 90

Summary of the content on the page No. 7

INSTALLATION INSTRUCTIONS 7. Tape the template (supplied in the chimney support carton) to Install Chimney Support the ceiling and mark the mounting holes, electrical hole and vent location (if used) on the ceiling. Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling. A ■ For plaster or drywall ceilings, the chimney support must be attached to joists. If this is not possible, you must build a B support structure behind the plaster or d

Summary of the content on the page No. 8

3. Attach the extension to the support using the 4 bolts supplied 9. Replace the four screws and tighten securely. with the extension kit. Tighten bolts securely. Make Electrical Connection A WARNING D C B Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. A. Chimney extension frame Failure to do so can result in death or electrical shock. B. Chimney support C. Bolt D. Captive threaded insert 1. Disconnect power. 2. Use twist-on connectors

Summary of the content on the page No. 9

4. Install the two vent extension pieces onto the diverter, pushing them until they stop. Install Chimney Covers A A Vented Installation Option 1. Attach the vent system to the damper. Seal all joints with duct tape. 2. Remove the plastic covering from the chimney covers. A. Vent extensions 3. Slide the upper chimney cover over the chimney support and attach to the top of the support using two screws provided. 5. Discard the lower chimney cover shipped with the hood and use the cover from the R

Summary of the content on the page No. 10

3. Slide the chimney cover provided with the extension kit over 2. From the underside of the hood, plug control cables together the lower chimney support and extension frame and secure to as shown. the top of the extension frame using the two screws provided. A 3. Insert each connected cable into a black plastic connector box half. B 4. Place the top half of the connector box on each and screw the two halves together using the four screws provided for each connector box. A C B A A. Screw B B. Up

Summary of the content on the page No. 11

2. Install grease filters using two hands by first pulling and turning the knob to the left so that the locking lever does not RANGE HOOD USE protrude from the filter. 3. Insert the opposite end of the filter into the retaining channel. Operation 4. Insert knob end and turn knob to the right to lock the filter into place. The hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes a

Summary of the content on the page No. 12

Replacing a halogen lamp This hood uses four 12-volt, 20 watt halogen lamps. RANGE HOOD CARE Turn off the range hood and allow the halogen lamps to cool. Replace bulb using a tissue to handle bulb, or wearing cotton Cleaning and Maintenance gloves. Do not touch bulb with bare fingers. Be sure lights are cool before cleaning the hood. 1. Disconnect power. Exterior surfaces 2. Remove 2 screws from the circular metal trim around the ■ Do not use steel wool or soap-filled scouring pads. lamp assemb

Summary of the content on the page No. 13

REQUESTING ASSISTANCE OR SERVICE If you need assistance or service in U.S.A. If you need assistance or service in Canada Call the KitchenAid Customer Interaction Center toll-free at For product related questions, please call the KitchenAid Canada 1-800-253-1301. Our consultants are available to assist you. Inc. Customer Interaction Center toll free: 1-800-461-5681 Monday to Friday 8:00 a.m. – 6:00 p.m. (EST). When calling: Please know the purchase date, and the complete Saturday 8:30 a.m. – 4:30

Summary of the content on the page No. 14

® KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter ì KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. ITEMS KITCHENAID WILL NOT PAY FOR 1. Service ca

Summary of the content on the page No. 15

WIRING DIAGRAM 15

Summary of the content on the page No. 16

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte

Summary of the content on the page No. 17

IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla

Summary of the content on the page No. 18

EXIGENCES D'INSTALLATION La hotte d'extraction a été configurée à l'usine pour la décharge à travers le toit ou à travers le mur. Pour une installation avec Outillage et pièces recyclage, voir “Installation avec recyclage, à la section Rassembler les outils et pièces nécessaires avant de commencer “Installation du cache-cheminée”. l'installation. Lire et suivre les instructions fournies avec les outils indiqués ici. On devra assurer l'étanchéité de toutes les ouvertures (plafond et mur) découp

Summary of the content on the page No. 19

■ Ne pas connecter ensemble deux raccords coudés. Dégagements de séparation à respecter ■ Assurer l'étanchéité de chaque jointure du circuit d'évacuation avec du ruban adhésif pour conduit. ■ Utiliser un calfeutrant pour assurer l'étanchéité autour de la bouche de décharge à l'extérieur, entre le conduit et l'ouverture à travers le toit ou le mur. Installation dans une région à climat froid Il convient d'installer un clapet anti-reflux additionnel pour minimiser les reflux d'air froid, et d'inst

Summary of the content on the page No. 20

Calcul de la longueur effective du circuit Spécifications électriques d'évacuation Pour calculer la longueur effective du circuit d'évacuation AVERTISSEMENT nécessaire, ajouter les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. La longueur équivalente du circuit ne doit pas dépasser 35 pieds (10,7 mètres). Composant du circuit Conduit rond dia. 6" (15,2 cm) Risque de choc électrique Coude à 45° 2.5 pi Déconnecter la source de courant électrique avant (0,


Alternative user manuals
# User manual Category Download
1 KitchenAid 30 User manual Ventilation Hood 4
2 KitchenAid 36"(91.4CM) ISLAND RANGE HOOD User manual Ventilation Hood 6
3 KitchenAid 36" (91.4 cm) 48" (121.9 cm) Island Canopy Range Hood User manual Ventilation Hood 4
4 KitchenAid 36 User manual Ventilation Hood 1
5 KitchenAid 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) Wall-Mount Canopy Range Hood User manual Ventilation Hood 7
6 KitchenAid 4329223 User manual Ventilation Hood 1
7 KitchenAid 4360369 User manual Ventilation Hood 1
8 KitchenAid 30" and 36" Retractable Downdraft Vent Systems User manual Ventilation Hood 7
9 KitchenAid 6899551 User manual Ventilation Hood 1
10 KitchenAid 48 User manual Ventilation Hood 1
11 KitchenAid 883297 User manual Ventilation Hood 1
12 KitchenAid 883298 User manual Ventilation Hood 2
13 KitchenAid 42 User manual Ventilation Hood 0
14 KitchenAid 6899552 User manual Ventilation Hood 1
15 KitchenAid 9763388 User manual Ventilation Hood 1
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0