Summary of the content on the page No. 1
I n s t a l l a t i o n G u i d e
81004 Ventura Bath Ventilator Fan With Light
READ and SAVE THESE INSTRUCTIONS
41787-01 1/11/2006
Summary of the content on the page No. 2
W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: 1. Use this unit only in a manner intended by the manufacturer. such as those published by the National Fire Prevention If you have questions, contact the manufacturer at the phone Association (NFPA), and the American Society for Heating, number or address listed in the warranty. Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 2. Before installing, servicing, or cle
Summary of the content on the page No. 3
95047-02-000 Check all the parts. D 95047-02-000 If damaged, call D 1-888-830-1326 77864-02 E 77864-02 for replacements. E 03242-07-133 F 03242-07-133 F A x4 A 96261-01-000 x4 G 96261-01-000 G 74508-03-133 B x2 H * 74508-03-133 B x2 H * 3/8" Cable Connector 95776-01-000 3/8" Cable Connector I 95776-01-000 I C * 75184-01-133 C J * 75184-01-133 J 96258-01/02/03-008 x2 H Extra Screws K 96258-01/02/03-008 x2 H Extra Screws K NOTE: Strain relief cable connector 75171-01/02/03-000 * L
Summary of the content on the page No. 4
New Construction Installation A2 A1 D Loosen screw securing motor. Remove the motor/blower from the housing. A3 A4 Remove packing material. Remove the pre-loaded screw tip covers. A5 A6 F Back out the pre-loaded screw tips until flush with the Remove the wiring cover screw. side of the housing. 41787-01 1/11/2006 4
Summary of the content on the page No. 5
A8 A7 E D Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. A9 A10 D C 5/8 5/8 1/2 1/2 B Insert the strain relief into the housing and secure Position the correct depth mark at the bottom edge with the washer. of the joist–based on the thickness of your sheet rock. OPTION A11 Screw pre-loaded screws into joist or framing. Nail the tabs on both sides to joist or framing so that the housing will be flush with the finished ceiling. (Nails are not provided.)
Summary of the content on the page No. 6
A12 A13 Tighten the strain relief screws. Pull the wires through the strain relief. Ground A14 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A15 A0 16 D D E F Install the wiring cover plate. Make sure all wiring Connect a 4” duct and vent to the outside. Tape joints. connections are inside the box or under the wiring cover plate. If duc
Summary of the content on the page No. 7
ON OFF 0000 A17 A18 0000 D D G G Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A20 A19 H Secure the motor by tightening the 2 screws. Turn on the power source. A21 A22 Go to step C1 on page 12 to attach grille. Test the motor. If the motor does not run, check the plug connection. 41787-01 1/11/2006 7
Summary of the content on the page No. 8
7.25” Existing Construction Installation D Use the motor housing as a template to mark position. Cut out an opening for the housing. Existing Fan B1 D Remove the existing fan and check to make sure the Loosen screw securing motor. opening is large enough to accommodate the new motor housing (7.25” x 7.75”). B3 B2 Remove packing material. Remove the motor/blower from the housing. 41787-01 1/11/2006 8 7.75”
Summary of the content on the page No. 9
B4 B5 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. B6 B7 E E Remove the wiring cover screw. Remove the wiring cover. B8 B9 D C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. 41787-01 1/11/2006 9
Summary of the content on the page No. 10
B11 B10 D Move the housing into position above the ceiling. Pull the wires through the strain relief and tighten the strain relief screws. B12 B13 D Attach existing ducting to duct connector. Tape joints. Fit housing into the opening and secure by tightening the If ducting does not fit securely, pre-loaded screws into the joist. an adapter may need to be purchased. Note: Install the box flush with the sheetrock (ceiling). B14 D Connect the wiring. 41787-01 1/11/2006 10 2 1
Summary of the content on the page No. 11
Ground B15 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. B16 B17 D D F E Install the wiring cover plate. Make sure all wiring Connect wiring from the motor to the wiring cover plate. connections are inside the box or under the wiring cover plate. B19 B18 0000 D H G Reinstall the motor by inserting the tabs and pushing up Secure the mot
Summary of the content on the page No. 12
ON OFF B20 B21 Test the motor. If the motor does not run, Turn on the power source. check the plug connection. B22 Go to step C1 to attach grille. Attaching the Grille C1 C2 I J K L Remove the thumbscrews. Remove glass dome. 41787-01 1/11/2006 12
Summary of the content on the page No. 13
C3 C4 I I Connect wiring harness. Slide light mount over posts. C5 C6 I J Attach thumbscrews. Install 2 Max 60 Watt A15 bulbs (Not Included). WARNING: To reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. C7 C8 K L Align glass dome and push up. Screw glass dome into position. 41787-01 1/11/2006 13
Summary of the content on the page No. 14
Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Light does not come on. Solution: • Replace the light bulb with a new bulb. • Turn power on, repl
Summary of the content on the page No. 15
Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed
Summary of the content on the page No. 16
2500 Frisco Avenue, Memphis, Tennessee 38114 Printed in China 41787-01 1/11/2006
Summary of the content on the page No. 17
DESDE G u í a d e i n s t a l a c i ó n Ventilador para baño 81004 Ventura con luz LEA y CONSERVE ESTAS INSTRUCCIONES 41787-021/11/2006
Summary of the content on the page No. 18
A D V E R T E N C I A PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA O LESIONES, OBSERVE LO SIGUIENTE: normas de seguridad, como las de la Asociación Nacional de 1. Utilice esta unidad sólo de la manera indicada por el fabricante. Protección contra Incendios (NFPA), la Asociación de Ingenieros Si tiene alguna pregunta, contacte con el fabricante en el Americanos en Calefacción y Aire acondicionado (ASHRAE), y teléfono o la dirección indicados en la garantía. los códigos locales.
Summary of the content on the page No. 19
Check all the parts. 95047-02-000 D If damaged, call 95047-02-000 D 1-888-830-1326 77864-02 E for replacements. 77864-02 E 03242-07-133 F 03242-07-133 x4 A F 96261-01-000 x4 A G 96261-01-000 G 74508-03-133 B x2 H * 74508-03-133 B Conector de cable de 3/8” x2 H * 95776-01-000 I Conector de cable de 3/8” 95776-01-000 C I * 75184-01-133 C J * 75184-01-133 J x2 H 96258-01/02/03-008 Tornillos adicionales K x2 H 96258-01/02/03-008 Tornillos adicionales NOTA: K Debe estar instalado el * 75171-01/02
Summary of the content on the page No. 20
Instalación para construcción nueva A2 A1 D Afloje el tornillo que asegura el motor. Retire el motor/soplador del alojamiento. A3 A4 Retire las cubiertas de las puntas de tornillo precargadas. Retire el material de embalaje. A5 A6 F Retire las puntas de tornillo precargadas hasta que estén Retire el tornillo de la cubierta del cableado. a nivel con el lado del alojamiento. 41787-02 1/11/2006 4