Summary of the content on the page No. 1
ENGLISH ESpAOL
See page 2 Vea la página 21
Installation Guide
ñ
™
90052/90053/90054/90058 Saturn Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
1
41718-01 01/28/2008
028_41718_EngS_1.28.08_Arial.indd 1 1/28/08 10:47:06 AM
Summary of the content on the page No. 2
W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO pERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in a manner intended by the manufacturer. American Society for Heating, Refrigeration and Air-Conditioning If you have questions, contact the manufacturer. Engineers (ASHRAE), and the local code authorities. 2. Before servicing or cleaning the unit, switch power off at ser- 5. When cutting or drilling into wall(s) or ceiling, do not damage vice panel and lock the service
Summary of the content on the page No. 3
95044-01-000 Check all the parts. D If damaged, call 95029-01-000 1-888-830-1326 E for replacements. 75191-01-000 F x4 A 03242-07-133 G 95491-01-000 H B * 74508-03-133 x2 I 3/8” Cable Connector 77521-01 J C * 65219 K x2 I Extra Screws 95583-01/02/03/04-000 L NOTE: Strain relief cable 75184-01-133 * M connector must be installed. Not Included. 94990-01/02/03-000 N Included. Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packin
Summary of the content on the page No. 4
4 3 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. 8 7 F G Remove the wiring cover screw. Remove the wiring cover. 4 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 4 1/28/08 10:47:11 AM
Summary of the content on the page No. 5
9 10 E C B pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 New Construction - attaching to joist A
Summary of the content on the page No. 6
A13 pull wires through the strain relief. A14 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A106 A15 E G Connect 4” duct and vent to the outside. Tape joints. Install the wiring cover plate. Make sure all If ducting does not fit securely, an adapter may need wiring connections are inside the box or under to be purchased. the wiri
Summary of the content on the page No. 7
ON OFF 0000 A17 A18 0000 H Reinstall the motor by inserting the tabs and pushing up into Connect wiring from the motor to the wiring cover plate. position. Make sure the wires are not pinched between the motor and the housing. A19 A20 I Secure the motor by tightening the 2 screws. Turn on the power source. A21 A22 Go to step E1 on page 17 to attach grille. Test the motor. If the motor does not run, check the plug connection. 7 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 7 1/28/
Summary of the content on the page No. 8
New Construction – suspended between joists B12 B11 E D 5/8 5/8 1/2 1/2 Slide the mounting rails into brackets. position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 1/8” Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline. B15 B16 Insert screws, leaving space between the screw Attach the rails onto the screws. head and the joist. Screws are not provided. 8 41718-01 01/28/2008
Summary of the content on the page No. 9
B17 B18 Tighten screws. pull wires through the strain relief. Ground B19 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. B20 B21 F G Connect 4” duct and vent to the outside. Tape joints. Install the wiring cover plate. Make sure all wiring If ducting does not fit securely, an adapter may need connections are inside the box or under the to
Summary of the content on the page No. 10
ON OFF B22 B23 H H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B24 B25 I Secure the motor by tightening the 2 screws. Turn on the power source. B26 B27 Go to step E1 on page 17 to attach grille. Test the motor. If the motor does not run, check the plug connection. 10 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 10 1/28/08 1
Summary of the content on the page No. 11
8” Existing Construction – accessible from above EXISTING FAN NO EXISTING FAN C11 OR Remove an existing fan and check to make sure the Use the motor housing as a template to mark position. opening is large enough to accommodate the new motor housing (8”x 8.5”). C12 E D Cut out an opening for the housing. Slide the mounting rails into brackets. C14 C13 5/8 5/8 1/2 1/2 position the correct depth mark at the bottom edge of the Mark position of screws by using holes as a template. joist based o
Summary of the content on the page No. 12
C15 C16 1/8” Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws. C19 C20 Connect 4” duct and vent to the outside. Tape joints. pull wires through the strain relief. If ducting does not fit securely, an adapter may need to be purchased. 12 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 12 1/28/08 10:47:33 AM
Summary of the content on the page No. 13
C21 Tighten the strain relief screws. C22 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. C23 C24 F H G Install the wiring cover plate. Make sure all wiring Connect wiring from the motor connections are inside the box or under the to the wiring cover plate. wiring cover plate. 13 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.ind
Summary of the content on the page No. 14
ON OFF C26 C25 I H Secure the motor by tightening the 2 screws. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. C27 C28 Turn on the power source. Test the motor. If the motor does not run, check the plug connection. C29 Go to step E1 on page 17 to attach grille. 14 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 14 1/28/08 10:47:38 AM
Summary of the content on the page No. 15
Existing Construction – accessible only from below EXISTING FAN D11 D12 E Remove an existing fan and check to make sure the Move the housing into position above the ceiling. opening is large enough to accommodate the new motor housing (8”x 8.5”). D13 D14 pull wires through strain relief. Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. D15 E Screw pre-loaded screws into joist or framing. 15 41718-01 01/28/2008 0
Summary of the content on the page No. 16
D16 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. D17 D18 F H G Install the wiring cover plate. Make sure all wiring Connect wiring from the motor to the wiring cover plate. connections are inside the box or under the wiring cover plate. D20 D19 I H Reinstall the motor by inserting the tabs and pushing up into Secure the motor
Summary of the content on the page No. 17
ON OFF D22 D21 Turn on the power source. Test the motor. If the motor does not run, check the plug connection. D23 Go to step E1 on page 17 to attach grille. Attaching the Grille E1 E2 E M L Connect wiring harness. Remove the thumbscrews. 17 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 17 1/28/08 10:47:45 AM
Summary of the content on the page No. 18
E3 E4 J K Remove the strain relief bracket screw. position the strain relief bracket under the motor as shown. E5 E6 L Insert the strain relief bracket’s dog-leg tab so that Align posts A, B, C and D (stamped into motor housing) it hooks over the lip of the motor. Reinstall the with posts A, B, C and D (stamped into light fixture). strain relief bracket screw. Slide light fixture over posts. E8 E7 M Attach thumbscrews. Install 2 Max 60 watt A-15 bulbs (Not Included). WARNING: To reduce the
Summary of the content on the page No. 19
E9 E10 N Align glass dome and push up. Screw glass dome into position. Trouble Shooting problem: Fan does not come on. Solution: • Hunter Fan Bath V entilators are extremely quiet. T o confirm that the fan is running, place your hand near the vents to feel the air movement. • T urn power on, replace fuse, or reset breaker . • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. problem: Light does not come on.
Summary of the content on the page No. 20
Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed a