Hotpoint HHC6.7AB user manual

User manual for the device Hotpoint HHC6.7AB

Device: Hotpoint HHC6.7AB
Category: Ventilation Hood
Manufacturer: Hotpoint
Size: 2.8 MB
Added : 6/26/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hotpoint HHC6.7AB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hotpoint HHC6.7AB.

For your convenience

If looking through the Hotpoint HHC6.7AB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hotpoint HHC6.7AB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hotpoint HHC6.7AB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hotpoint HHC6.7AB User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hotpoint HHC6.7AB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hotpoint HHC6.7AB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HHC6.7AB
HHC9.7AB
HHC7.7AB
English
Operating Instructions
COOKER HOOD
Contents
Operating Instructions,1
Warnings,7
Installation,9
CHIMNEY controls,10
Maintenance and care,11
Troubleshooting,12
After Sales Service,14
Guarantee,15
Please phone us on
08448 24 24 24
to activate your
guarantee

Summary of the content on the page No. 2

6x Ø 8 x 40 6x Ø 5 x 45 4x Ø 3,5 x 9,5 1x 2x ø 150-125mm ø 150mm 1x 1x 1x 2 5 2 3 4

Summary of the content on the page No. 3

1A Ø120mm Ø120mm Ø150mm Ø150mm Ø120 Ø120 Ø150 Ø150 1B Ø150mm 3 32 cm min.

Summary of the content on the page No. 4

= = = = 550 mm 650 mm 2 3 x6 4 5 Ø 8 mm x6 x6 7 6 x2 4 5 mm

Summary of the content on the page No. 5

8 9 1 2 3 x2 ø 150 ø 120 10 11 x2 12 13 5

Summary of the content on the page No. 6

14 x2 ø 150 ø 3,5 x 9,5 15 16 17 18 B A 6

Summary of the content on the page No. 7

• Before cleaning or servicing the unit, disconnect it from the mains by pulling the power plug or disconnecting the main circuit breaker. Warnings ! Keep this manual for reference. If you • Always wear work gloves when installing sell, transfer or move the unit to another and servicing the unit. location, make sure to keep the manual with the product. • It is not intended for use by children or persons with sensory or mental ! Read the instruction

Summary of the content on the page No. 8

• Strictly observe all local regulations in relation to the technical and safety measures to be employed in fumes extraction. • Clean the product frequently , inside and out (AT LEAST ONCE A MONTH, and in observance of the maintenance instruction given in this manual). • Failure to observe the hood cleaning and filter cleaning/replacement instructions can result in fires. • Never use the hood without its bulbs properly installed -

Summary of the content on the page No. 9

Installation Ducted version GB The installation procedure is illustrated in the first pages The hood purifies the air and expels it outdoors via an of this manual. exhaust duct (dia. 150mm) connected to its outlet flange. The installation must be done by a qualified technician. The diameter of the exhaust tube must be equal to that of the outlet flange. Electrical hook up Caution! The exhaust duct is not supplied and must be The mains voltage must matc

Summary of the content on the page No. 10

Grease/odour filter warnings CHIMNEY controls GB The T2 icon flashes to indicate that the grease filter is saturated, while T3 flashes to indicate that the odour filter Models with mechanical keypad is saturated, and if both are flashing then both filters are (Only available in certain models) saturated. You must then clean/replace the grease filter (A) or odour filter (B) or both, accordingly (see “Maintenance and care”). T1 T2 T3 T4 T

Summary of the content on the page No. 11

Grease/odour filter warnings Periodic cleaning GB The bar at the top left flashes to indicate The hood must be cleaned frequently (at least as often as that the grease filter is saturated. you service the grease filter), inside and out. Use a damp cloth and a neutral liquid detergent with lukewarm water. Do not use abrasive or corrosive products. Warning: Failure to observe the hood cleaning and filter The bar at the top right flashes to indicate cleaning/

Summary of the content on the page No. 12

Replacing the bulbs Troubleshooting GB Disconnect the unit from the mains and remove the grease filter . If something does not work, make the following simple Caution! Make sure the bulbs are cool before touching checks before contacting Technical Service: them. If the hood does not operate: 1. Extract the guard by prising it out with a small flat head Check that: screwdriver or something • the unit is powered up. similar. • a speed has been set. 2. Replace the faulty bulb. Use

Summary of the content on the page No. 13

GB PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 13

Summary of the content on the page No. 14

After Sales Service GB No one is better placed to care for your Hotpoint appliance during the course of its working life than us – the manufacturer. Essential Contact Information Hotpoint Service We are the largest service team in the country offering you access to 400 skilled telephone advisors and 1000 fully qualified engineers on call to ensure you receive fast, reliable, local service. UK: 08448 224 224 Republic of Ireland: 0818 313 413 www.hotpointservice.co.uk Please note: Our advisors w

Summary of the content on the page No. 15

Guarantee GB 12 months Parts and Labour Guarantee Your appliance has the benefit of our manufacturer’s guarantee, which covers the cost of breakdown repairs for twelve months from the date of purchase. This gives you the reassurance that if, within that time, your appliance is proven to be defective because of either workmanship or materials, we will, at our discretion, either repair or replace the appliance at no cost to you. This guarantee is subject to the following conditions: - The applia

Summary of the content on the page No. 16

195107498.03 03/2013 - XEROX FABRIANO GB PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 16


Alternative user manuals
# User manual Category Download
1 Hotpoint Cannon Cooker Hood BCH100 User manual Ventilation Hood 0
2 Hotpoint HD 7 User manual Ventilation Hood 0
3 Hotpoint HD 9 User manual Ventilation Hood 0
4 Hotpoint HD 6 User manual Ventilation Hood 0
5 Hotpoint HC9X User manual Ventilation Hood 1
6 Hotpoint EV302X User manual Ventilation Hood 0
7 Hotpoint HD90X User manual Ventilation Hood 1
8 Hotpoint HD 93 X User manual Ventilation Hood 4
9 Hotpoint HDI90X User manual Ventilation Hood 1
10 Hotpoint HE61 User manual Ventilation Hood 1
11 Hotpoint HE63 HE73 HE93 User manual Ventilation Hood 5
12 Hotpoint HE91 User manual Ventilation Hood 1
13 Hotpoint HCC7.7AB User manual Ventilation Hood 1
14 Hotpoint HHC6.7AM(WH) User manual Ventilation Hood 1
15 Hotpoint HHC9.7AB User manual Ventilation Hood 2
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0