Honeywell Y8150 user manual

User manual for the device Honeywell Y8150

Device: Honeywell Y8150
Category: Ventilation Hood
Manufacturer: Honeywell
Size: 1.14 MB
Added : 4/13/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell Y8150. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell Y8150.

For your convenience

If looking through the Honeywell Y8150 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell Y8150 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell Y8150 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell Y8150 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell Y8150 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell Y8150. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Y8150 Fresh Air Ventilation System,
W8150 Fresh Air Ventilation Control
PRODUCT DATA
FEATURES
• Designed to help meet local ventilation codes and
standards, including ASHRAE 62.2-2010 standard,
“Ventilation and Acceptable Indoor Air Quality in
Low-Rise Residential Buildings.”
• Microcontroller optimizes the air delivery schedule to
make efficient use of normal HVAC run times.
• Easy-to-use input dials allow customized ventilation
for each installation.
• Test mode that includes immediate f

Summary of the content on the page No. 2

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL SPECIFICATIONS Y8150 includes: W8150A Fresh Air Ventilation Control. 4-3/16 (106) 1-1/4 (32) EARD6 Fresh Air Damper. AT120B Transformer. Mounting hardware for control. Homeowner information label. W8150 includes: W8150 Fresh Air Ventilation Control. 5-3/4 (146) Mounting hardware for control. Homeowner information label. Control (W8150A): Power Supply: 20-30 Vac, 60 Hz. Power Consumption: 3.5 VA at 24 Vac. Thermostat Fan Loa

Summary of the content on the page No. 3

ON Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL XFMR 1 GF R 20 2 RC C 19 3 CC 4 CH 18 5 W GT 6 17 7 8 16 9 15 10 14 11 12 BEDROOMS AREA (SQFT) VENT AIRFLOW (CFM) 13 M19990 W8150 QUICK GUIDE No. Name Description Function 1GF Equipment fan Allows W8150 to pass thermostat calls and, when necessary, turn on system fan for ventilation. This should be the only connection to G on the HVAC equipment. 2RC 24 Vac cooling system Provides power to GF terminal to operate system

Summary of the content on the page No. 4

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL No. Name Description Function 16 REMOTE Remote switch (two 24 Vac powered contacts allow a remote switch closure to call for terminals) ventilation. 17 AUX Auxiliary (two terminals) 24 Vac dry contacts allow W8150 to control an auxiliary device, such as exhaust fan or HRV/ERV, with a call for ventilation. 18 DAMPER Damper (two terminals) 24 Vac powered contacts control fresh air damper. 19 XFMR C 24 Vac ventilation contro

Summary of the content on the page No. 5

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL Installing fresh air damper, ducting, Wiring the control… and control… 1. Disconnect power from HVAC system. CAUTION 2. Install the weather hood, ducting, and damper following local practices. Be sure all duct and insulation seams Electrical Hazard. are tightly sealed. Can cause personal injury or equipment damage. 3. Mount the transformer and control. Disconnect power to all systems before beginning installation. TIPS: 1

Summary of the content on the page No. 6

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL Measuring airflow… About the control settings… 1. Make sure all HVAC system air filters are clean and installed. Dial Settings 2. Push Test button: These settings allow the installer to customize the control to • Control opens damper and turns on HVAC fan for meet the ventilation requirements for the home. three minutes. • A red or green light is flashing; you can now measure airflow. Ventilation Standard 3. Follow inst

Summary of the content on the page No. 7

1 Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL TIPS: Setting the control... • Ventilation control reads new dial setting only when test 1. Be sure power is turned on. button is pushed or power is cycled. To ensure dial settings 2. Set the Ventilation Standard on the control. are read, push test button after any changes are made. 3. Set the bedrooms dial. • For single bedroom homes, set the bedrooms dial to 2 (this 4. Set the area (sq ft) dial. may result in more ven

Summary of the content on the page No. 8

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL CHECKOUT In this section, make sure the ventilation system is operating TIP: correctly. • W8150 Ventilation Control automatically exits test mode after three minutes. 1. On thermostat, set Fan switch to Auto and System switch to Off. 2. Set any remote switches throughout the house in the Off position. 3. On the W8150, set the control switch to Off (remote only). 4. Press Test button for two seconds to enter test mode: •

Summary of the content on the page No. 9

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL Problem Possible cause What to do HVAC fan is running all Device is set to override • Move switch to On position to allow for automatic operation. the time Remote switch is on • Adjust remote switch to desired position. Thermostat Fan switch is • Normal operation. in On position HVAC system is running • Normal operation. to satisfy heating or cooling requirements. Ventilation limit is set to • Set ventilation limit to 60%.

Summary of the content on the page No. 10

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL WIRING DIAGRAMS Consult thermostat Installation Instructions for alternate HVAC terminal designations. HVAC RW C W1 2 Y1 Y2 G RC W Y G W8150A GF RC W8150A CC GF CH RC W CC GT CH W GT RW RC C W1 2 Y1 Y2 G System Heat AM Fan Tue Room Wake DST Auto RRC WY G System Heat AM Fan Tue Room M19996 Wake DST Auto Fig. 3. Multi-stage conventional system. M19994A Fig. 1. Single transformer, conventional system. HVAC HVAC RC Y G O HEATI

Summary of the content on the page No. 11

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL HVAC AT120 EARD-6 RW C Y2EGO XFMR FAN TIMER R W8150A GF W8150A C RC Ventilation Control Auto CC Continuous Off (Remote Only) Service CH Ventilation Control W GT M22000 RW C W1 Y1 2 E G O/B System Heat AM Fan Tue Room Wake DST Auto Fig. 7. Using a remote switch or timer. M19998A AT120 HR150/ER150 Fig. 5. Wiring heat pump with emergency heat. XFMR EARD-6 W8900 R AT120 W8150A C RED BLACK Ventilation Control Auto

Summary of the content on the page No. 12

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL •100 cfm. HVAC CONVERSION TABLE RW C W1 2 Y1 Y2 G W8150A GF Area Airflow RC sq ft sq m cfm lps HE440 CC FAN 1000 93 40 19 CH W 1300 121 50 24 GT 1600 149 60 28 RED BLACK 1900 177 70 33 R8222 2200 204 80 38 2500 232 90 42 BLUE BLUE 2800 260 100 47 3100 288 110 52 RW RC C W1 2 Y1 Y2 G System 3400 316 120 57 Heat AM Fan Tue Room Wake DST Auto 3700 344 130 61 M22021A 4000 372 140 66 4300 399 150 71 4600 427 160 76 Fig. 10. Wirin


Alternative user manuals
# User manual Category Download
1 Honeywell 69-2480EF05 User manual Ventilation Hood 2
2 Honeywell VNT5200H1000 User manual Ventilation Hood 7
3 Honeywell ER200B2006 User manual Ventilation Hood 5
4 Honeywell EXCEL 10 W7753A User manual Ventilation Hood 0
5 Honeywell VNT5150E1000 User manual Ventilation Hood 0
6 Honeywell PERFECT WINDOW ER200 User manual Ventilation Hood 0
7 Honeywell VNT5200E1000 User manual Ventilation Hood 0
8 Honeywell VNT5150H1000 User manual Ventilation Hood 1
9 Honeywell HR230 User manual Ventilation Hood 0
10 Honeywell ER150B2006 User manual Ventilation Hood 0
11 Honeywell PERFECT WINDOW ER150 User manual Ventilation Hood 0
12 Honeywell PERFECT WINDOW ER150C User manual Ventilation Hood 0
13 Honeywell PERFECT WINDOW HR150 User manual Ventilation Hood 0
14 Honeywell PERFECT WINDOW ER200C User manual Ventilation Hood 0
15 Honeywell PERFECT WINDOW HR200 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0