Summary of the content on the page No. 1
HR150 and HR200
Perfect Window Fresh Air
Ventilation Systems
OWNERS MANUAL
M11706
® U.S. Registered Trademark
Copyright © 2002 Honeywell
All Rights Reserved
69-0994-4
Summary of the content on the page No. 2
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS TABLE OF CONTENTS Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Feeling right at home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 What your Perfect Window Fresh Air Ventilation System consists of . . . . . . . . . . .4 Operating your Fresh Air Ventilation System . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 3
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Introduction We take it for granted that our homes will protect us from the elements, but because of tighter, better quality home construction, our indoor environment may be exposing us to unacceptable levels of the very things we are trying to escape. Excessive heat, dryness, humidity, toxic gases and dust contaminants can be sealed in securely by weatherproofing. So whats the forecast for indoors? Todays indoor forecast is sto
Summary of the content on the page No. 4
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS 3. Condensate Tray and Drain Condensation normally forms on the heat exchange core during the cold weather (below 29°F or -2°C). Moisture can build up when the warm air from your home comes in contact with the cold air from outside. The tray collects the moisture and funnels it to the drain. The drain pans are made of therrnoformed plastic for easy cleaning. 4. Defrost Mechanism The built-in defrost mechanism will remove frost whi
Summary of the content on the page No. 5
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Operating your Fresh Air Ventilation System Changing Fan Speed The control fan speed is conveniently located on the ventilator. The rotary fan speed control knob can be manually set from the off (standby) position through speeds 1 to 4. Note the fifth speed (high) is accessible only by a remote control. Off/standby mode may be used if intermittent ventilation is desired. In the off/standby position, the ventilator will not function
Summary of the content on the page No. 6
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS EXTERNAL REMOTE WALL CONTROL (DEHUMIDISTAT) The dehumidistat (connected to your ventilator) is designed to control the operation of the ventilator fan to help keep the humidity level in your home comfortable. If an independent humidifier is installed and set at 30% (a normal indoor winter level) then the dehumidistat (for the ventilator) should be set at least 10% higher, in this case 40%. With the ventilator operating on low spee
Summary of the content on the page No. 7
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Maintenance Instructions for your Fresh Air Ventilation System WARNING Electrical Shock Hazard. Can cause personal injury or equipment damage. Disconnect power supply before performing maintenance. The Perfect Window Fresh Air Ventilation System must be maintained on a regular basis for best efficiency. Honeywell recommends that the ventilator be cleaned and checked at least twice a year, preferably at the beginning of each heating
Summary of the content on the page No. 8
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS CORE Clean the core twice each year. FILTER CLIP FILTER CORE GUIDE M11702A MANUAL CONTROL MODEL 1. Open the access door and carefully grip the ends of the core and pull evenly out- ward. The core can be snug, but it will slide out of the cabinet. NOTE: Do not handle the fins because damage can occur. 2. Once out of the cabinet, remove the filters (refer to Air Filter Maintenance sec- tion). 3. Wash the core in warm soapy waterdo not
Summary of the content on the page No. 9
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS DRAIN LINE Clean the drain line once a year. 1. Inspect the drain line, drain spout and P trap for blockage, mold or kinks. 2. Flush with warm soapy water and replace if worn or bent, or if it can not be cleaned. GENERAL MAINTENANCE Twice a year wipe down the inside of the cabinet with a damp cloth to remove dirt, bugs and debris that can be present. FANS If the fans accumulate dirt, it could cause an imbalance and excessive vibrati
Summary of the content on the page No. 10
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Perfect Climate® Control Describing Perfection The most convenient, most energy efficient, cleanest, healthiest and most comfortable indoor environment, possible today! Perfect climate is achieved when the six core components of your homes climate system work together: optimal efficiency of heating and cooling equipment precise, programmable temperature control effective indoor air quality control controlled humidity prope
Summary of the content on the page No. 11
HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Troubleshooting Lack of power to the ventilator: power failure of electrical box. loose or unplugged power cord. faulty breaker or fuse in homes electrical panel. call your installation contractor. Power to the ventilator, but no fan operation: ventilator is in standby mode and optional remote dehumidistat is set to OFF or the humidity setting is higher than room humidity. door Is not closed properly, the safety interloc
Summary of the content on the page No. 12
Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywells option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the r