ER150C and ER200C
Perfect Window Fresh Air
Ventilation Systems
OWNERS MANUAL
M11706
® U.S. Registered Trademark
Copyright © 2002 Honeywell
69-1563-1
All Rights Reserved
Summary of the content on the page No. 2
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS TABLE OF CONTENTS Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Feeling right at home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 The Perfect Window Fresh Air Ventilation System consists of . . . . . . . . . . . . . . . .3 Operating your Fresh Air Ventilation System . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 3
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS Introduction We take it for granted that our homes will protect us from the elements, but because of tighter, better quality home construction, our indoor environment may be exposing us to unacceptable levels of the very things we are trying to escape. Excessive heat, dryness, humidity, toxic gases and dust contaminants can be sealed in securely by weatherproofing. So whats the forecast for indoors? Todays indoor forecast is sto
Summary of the content on the page No. 4
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS . CORE INSTRUCTIONS ENERGY TRANSFER CORE CABINET FILTERS (2) DUCTING (4 PORTS) MAIN MOTOR SQUIRREL CAGE FAN CORE GUIDE CHANNEL (4) INSULATED ACCESS DOOR DOOR KEEPER PLATE (2) M20143 3. Energy Transfer Core As the exhaust and fresh air pass through opposite sides of the Energy Transfer Core heat is transferred from the warm side to the cold side. This heat transfer reduces the cost of conditioning the fresh outside air that is bro
Summary of the content on the page No. 5
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS It is up to the individual homeowner to set their system to a speed which they find comfortable. If you feel your house is stuffy or there is an above average occupancy rate, you may need to increase your ventilation. In most applications a low to medium speed setting is comfortable. Connecting a Remote Device Your ventilator comes equipped with a low voltage terminal strip for connection to several optional control devices. PERFE
Summary of the content on the page No. 6
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS Getting the most from your Fresh Air Ventilation System HOW MUCH VENTILATION DO I NEED? During the seasons that your windows and doors are closed (winter and summer if you have air conditioning), the ventilator should operate continuously when the home is occupied, and either continuously or intermittently when not occupied. For most installations, the ventilator will normally be set to operate continuously on low speed with the o
Summary of the content on the page No. 7
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS FILTER CLIP FILTER CORE GUIDE CHANNEL M11899 WARNING Carbon Monoxide Hazard. Can cause personal injury or equipment damage. Hood blockage can cause a change of pressure in building which can lead to possible spillage from combustible appliances. AIR FILTERS Air filters should be cleaned twice a year. The standard filters supplied with your ventilator are removable and washable. 1. Open access door and slide out core. Refer to Core M
Summary of the content on the page No. 8
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS 2. Once out of the cabinet, remove the filters (refer to Air Filter Maintenance sec- tion). 3. When the core is dry, clean it with only a vacuum cleaner. Vacuum the filter sides of the core by pulling any dirt back out of the core, not by pulling dirt all the way through the core. 4. Reinstall the clean filters. 5. Reinstall the clean core. TO INSTALL THE CLEAN CORE: 1. First mount the bottom core guide into the bottom Core Guide Ch
Summary of the content on the page No. 9
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS Perfect Climate® Control Describing Perfection The most convenient, most energy efficient, cleanest, healthiest and most comfortable indoor environment, possible today! Perfect climate is achieved when the six core components of your homes climate system work together: optimal efficiency of heating and cooling equipment precise, programmable temperature control effective indoor air quality control controlled humidity prope
Summary of the content on the page No. 10
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS Troubleshooting Lack of power to the ventilator: power failure of electrical box. loose or unplugged power cord. faulty breaker or fuse in homes electrical panel. call your installation contractor. Power to the ventilator, but no fan operation: ventilator is in standby mode and optional remote dehumidistat is set to OFF or the humidity setting is higher than room humidity. door Is not closed properly, the safety interloc
Summary of the content on the page No. 11
ER150 AND ER200 Perfect Window FRESH AIR VENTILATION SYSTEMS Limited Warranty Honeywell warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywells option) within a reasonable period of time. If the product is defective (i) return it,
Summary of the content on the page No. 12
Automation and Control Solutions Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% 59-1563-1 G.H. Rev. 01-02 www.honeywell.com/yourhome post-consumer paper fibers.