Honeywell VNT5150H1000 user manual

User manual for the device Honeywell VNT5150H1000

Device: Honeywell VNT5150H1000
Category: Ventilation Hood
Manufacturer: Honeywell
Size: 5.74 MB
Added : 4/13/2013
Number of pages: 68
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell VNT5150H1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell VNT5150H1000.

For your convenience

If looking through the Honeywell VNT5150H1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell VNT5150H1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell VNT5150H1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell VNT5150H1000 User manual - Online PDF
Advertisement
« Page 1 of 68 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell VNT5150H1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell VNT5150H1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ERV/HRV Ventilation Systems

PROFESSIONAL INSTALLATION GUIDE.
GUIDE D’INSTALLATION PROFESSIONNELLE.
INCLUDED IN THIS BOX
A1 A2 B C
G1 G2 G3
D E F
ERV/HRV Ventilation Systems
PROFESSIONAL INSTALLATION GUIDE.
GUIDE D’INSTALLATION PROFESSIONNELLE.
INCLUDED IN THIS BOX
A1 A2 B C
G1 G2 G3
D E F G4 G5 G6
ERV/HRV Ventilation GUIDE S PROFESSIONAL y D’INS st Te ALLm ATION s INS PROFESSIONNELLE TALLATION GUIDE..
A1 INCLUDED IN THIS BOX A2 B C
D E F G1 G2 G3
Tools Alurmin equi um f red t oil tape (UL181

Summary of the content on the page No. 2

Installation Checklist Liste de vérification pour l’installation Included in This Box A1 ER V/HR V VNT5150H1000 or VNT5150E1000 or Contenu A2 ER V/HR V VNT5200H1000 or VNT5200E1000 A1 VRÉ/VRC VNT5150H1000 ou VNT5150E1000 ou B Heat/Energy Recovery Cor e A2 VRÉ/VRC VNT5200H1000 ou VNT5200E1000 C Filter (2) B Noyau de récupération de chaleur et d’énergie D Installation Guide C Filtr e (2) E Duct Collars (4) D Guide d’installation F Installation Kit E Raccor ds de conduit (4) F T r ou

Summary of the content on the page No. 3

ER V/HR V V entilation System ABOUT YOUR NEW VENTILA TION SYSTEM INSTALLATION (continued) Dehumidistat Wiring ............................................ 23 Benefits ....................................................................... 2 W8150 V entilation Contr ol Wiring ....................... 23 Determining Y our V entilation Needs .......................... 3 Honeywell 20/40/60 Minute Boost Contr ol Specifications .............................................................

Summary of the content on the page No. 4

About the ER V/HR V V entilation System T h e H o n e y w e l l E R V / H R V V e n t i l a t i o n S y s t e m p r o v i d e s impr oved indoor air quality thr ough its high performance and ef ficiency . Benefits • V entilation with sensible heat r ecovery (ER V and HR V) • V entilation with latent heat r ecovery (ER V only) • Simplified mounting (hanging) • Removable duct collars for easy ducting to the unit • Intuitive balancing via two var

Summary of the content on the page No. 5

Determining Y our V entilation Needs How much fr esh air do you need? Good air quality is based in part on the capacity of the home’ s ventilation system. Usually , the unit’ s capacity is measur ed in CFM (Cubic Feet per Minute) or L/s (Liters per second) of fr esh air being distributed in the living space. Use the ASHRAE 62.2 V entilation Standar d, the Room Count Calculation Method, or the Air Change Per Hour (ACH) Method to determ

Summary of the content on the page No. 6

Specifications Dimensions in inches (mm): 2 1 1 FRONT CLEARANCE OF 25 INCHES H (635 MM) IS REQUIRED FOR SERVICING UNIT. ALL DUCT CONNECTIONS ARE 2 6 IN. (150 MM). W L VNT5150H1000 or VNT5150E1000: H = 22 1/2 in. (572 mm), W = 11 1/2 in. (295 mm), L = 29 1/2 in. (749 mm) VNT5200H1000 or VNT5200E1000: H = 22 1/2 in. (572 mm), W = 16 1/2 in. (422 mm), L = 29 1/2 in. (749 mm) M28919 Physical Specifications: Model Product Weight Shipping Weight Heat/Energy Core Filter Dimensions Dimensions H =

Summary of the content on the page No. 7

Specifications (continued) VNT5150H1000 V entilation Performance Gross Air Flow External Static Pressure Net Supply Air Flow Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 92 195 92 196 113 241 50 0.2 85 182 86 183 105 223 75 0.3 80 171 81 172 91 193 100 0.4 73 156 74 157 84 178 125 0.5 65 139 66 140 75 159 150 0.6 59 126 60 127 65 137 175 0.7 56 120 57 120 57 120 200 0.8 50 107 50 107 48 103 225 0.9 45 95 45 96 40 86 250 1.0 37 79 38 80 34 73 VNT5150H1000 AIR FLOW (L/S) 0 10 20 30 40

Summary of the content on the page No. 8

Specifications (continued) VNT5200H1000 V entilation Performance Gross Air Flow External Static Net Supply Air Flow Pressure Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 117 248 118 250 130 277 50 0.2 108 229 109 231 119 253 75 0.3 102 218 103 220 110 234 100 0.4 94 200 95 202 101 216 125 0.5 85 181 86 183 92 197 150 0.6 77 163 78 165 82 175 175 0.7 69 146 70 148 71 151 200 0.8 61 129 61 131 60 128 225 0.9 52 110 52 111 49 104 250 1.0 45 96 46 97 40 86 VNT5200H1000 AIR FLOW (L/S) 0

Summary of the content on the page No. 9

Specifications (continued) VNT5150E1000 V entilation Performance Gross Air Flow External Static Pressure Net Supply Air Flow Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 92 197 96 204 93 199 50 0.2 87 185 93 199 88 186 75 0.3 82 173 88 186 82 175 100 0.4 75 160 83 176 76 162 125 0.5 69 146 76 162 70 148 150 0.6 62 132 72 152 63 134 175 0.7 55 116 67 143 55 117 200 0.8 48 102 60 127 48 103 225 0.9 41 88 54 114 42 89 250 1.0 38 81 42 89 39 82 VNT5150E1000 AIR FLOW (L/S) 0 10 20 30 40

Summary of the content on the page No. 10

Specifications (continued) VNT5200E1000 V entilation Performance Gross Air Flow External Static Net Supply Air Flow Pressure Supply Exhaust Pa in. W.C. L/s CFM L/s CFM L/s CFM 25 0.1 98 208 102 218 99 210 50 0.2 94 200 99 210 95 202 75 0.3 87 186 93 199 88 188 100 0.4 82 175 88 188 83 176 125 0.5 74 157 78 167 75 159 150 0.6 65 138 72 152 65 139 175 0.7 60 127 64 135 60 128 200 0.8 53 112 60 127 53 113 225 0.9 44 94 54 114 45 95 250 1 38 81 41 86 39 82 VNT5200E1000 AIR FLOW (L/S) 0 10 20 30 40

Summary of the content on the page No. 11

Exter nal Contr ol Options The ER V/HR V unit may be used with one of the following exter nal contr ols: Prestige™ (YTHX9321R5012) and Prestige™ IAQ Comfort System (YTHX9421R5028) • Contr ols both heating/cooling and ventilation. • Wir eless sensor for displaying outdoor temperatur e and humidity . • Advanced ventilation pr ogramming includes economizing and extr eme condition shutdown. • Maintenance and service r eminders. • High definition color display . VisionP

Summary of the content on the page No. 12

Install to Fit Y our Application NOTE: Prior to installing, serious consideration must be taken to insur e this ventilation system will operate pr operly if integrated with any other type of mechanical system, i.e. a for ced air system, or an air handling unit. T o insur e pr oper operation & compatibilities of both system, it is r equir ed that the airflows of ventilation systems be balanced, by following the pr ocedur es found in th

Summary of the content on the page No. 13

18 INCHES 6 FEET Install to Fit Y our Application (continued) Exhaust at the Source and Supply in the Return B STALE AIR FROM LIVING SPACE, SUCH AS FROM BATHROOM OR KITCHEN TO LIVING SPACE FORCED AIR HRV / ERV SYSTEM M28984 This application uses a devoted duct system for the exhausting of stale air accumulated in the home. The fr esh air is intr oduced into the r etur n air duct and is distributed thr ough the home by the existing supply air ductwork of t

Summary of the content on the page No. 14

18 INCHES 6 FEET Install to Fit Y our Application (continued) Exhaust and Supply in the Return C TO LIVING SPACE FORCED AIR SYSTEM HRV / ERV M28985 When using this application make sur e that ther e is a minimum of 6 feet between the fr esh air and exhaust air connections of the ER V/HR V unit in the r etur n air duct. Supply air fr om the ER V/HR V unit must be at least 3 feet fr om the for ced air system. These distances can be dif fer ent f

Summary of the content on the page No. 15

Installation Steps Installation Kit 1 Ensur e that you have all of the following installation items: 4 Duct Collars Installation Kit: • 2 Flexible 6 in. V inyl Ducts • 1 Condensation Drain Line (10 in.) • 1 Drain Adapter with Nut • 4 Tie W raps (30 in.) • 16 Hex-head scr ews (1/4 x 5/8 in.) • 4 Hex-head scr ews (1/4 x 1 in.) • 4 W ashers • 1 Drain cap (VNT5250E100 and VNT5200E1000 only) • 1 power cor d, 120 V ac (not shown) Installatio

Summary of the content on the page No. 16

Installation Steps (continued) Hanging the ERV/HRV 3 The ER V/HR V unit enables you to save time and ef fort by of fering a simplified hanging system. TIP: Removing the cor e unit makes installation easier since the unit weighs less without the cor e inside. 1. Attach straps to joist using the supplied 2. Pull on middle of strap while gently lifting unit washers and four 1 in. hex-head hanging upwar d to raise the unit. scr ews. 3. Make final adju

Summary of the content on the page No. 17

Installation Steps (continued) Installing the flex duct to the ERV/HRV 4 TIP: Honeywell r ecommends using appr oximately 16 inches of flexible duct (supplied in kit) between the unit and the rigid duct for noise dampening. The flex duct is mounted to the unit the same way as the insulated flex. 1. Insert the vinyl duct over the hooks on the 2. Insert insulation inside the outer ring of the duct duct collar and seal with a supplied 30 inch collar .

Summary of the content on the page No. 18

Installation Steps (continued) Installing the condensation drain line 5 Insert the thr eaded drain adapter thr ough the bottom of the unit and hand tighten the plastic nut supplied with the drain kit. Use a wr ench to tighten the nut another half tur n to ensur e a complete seal. Install the condensate tubing by pushing the clear plastic tubing over the drain adapter . Make a condensate trap by looping the clear plastic tubing. This

Summary of the content on the page No. 19

Installation Steps (continued) Connecting the power cord 6 ERV/HRV Power Cord Insert the power cor d on top of the unit. Pr ess firmly to make sur e the power cor d is secur e. IMPORTANT: Do not plug the power cor d into the wall r eceptacle at this time. Electric Wall Outlet Honeywell r ecommends that the unit has a dedicated r eceptacle with 120 V AC. A void connecting the unit to the wall r eceptacle with an extension cor d. Honeyw

Summary of the content on the page No. 20

Automated Defr ost The ER V and HR V units ar e equipped with an automatic defr ost featur e to eliminate any ice build up on the cor e. • Automatic defr ost is initiated once every hour when the fr esh air supply temperatur e dr ops to 23°F (-5°C) or colder . • The defr ost cycle operates by tur ning of f the supply fan while continuing to operate the exhaust fan. • The exhaust fan speed is adjusted pr oportionally based on the outdoor temperatur e, initially operating


Alternative user manuals
# User manual Category Download
1 Honeywell 69-2480EF05 User manual Ventilation Hood 2
2 Honeywell VNT5200H1000 User manual Ventilation Hood 7
3 Honeywell ER200B2006 User manual Ventilation Hood 5
4 Honeywell EXCEL 10 W7753A User manual Ventilation Hood 0
5 Honeywell VNT5150E1000 User manual Ventilation Hood 0
6 Honeywell PERFECT WINDOW ER200 User manual Ventilation Hood 0
7 Honeywell VNT5200E1000 User manual Ventilation Hood 0
8 Honeywell HR230 User manual Ventilation Hood 0
9 Honeywell ER150B2006 User manual Ventilation Hood 0
10 Honeywell PERFECT WINDOW ER150 User manual Ventilation Hood 0
11 Honeywell PERFECT WINDOW ER150C User manual Ventilation Hood 0
12 Honeywell PERFECT WINDOW HR150 User manual Ventilation Hood 0
13 Honeywell PERFECT WINDOW ER200C User manual Ventilation Hood 0
14 Honeywell PERFECT WINDOW HR200 User manual Ventilation Hood 0
15 Honeywell W7340 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0