Greenheck Fan QEP user manual

User manual for the device Greenheck Fan QEP

Device: Greenheck Fan QEP
Category: Ventilation Hood
Manufacturer: Greenheck Fan
Size: 3.12 MB
Added : 1/6/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Greenheck Fan QEP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Greenheck Fan QEP.

For your convenience

If looking through the Greenheck Fan QEP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Greenheck Fan QEP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Greenheck Fan QEP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Greenheck Fan QEP User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Greenheck Fan QEP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Greenheck Fan QEP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Plenum Fans
Models QEM and QEP
Belt and Direct Drive
September
2008

Summary of the content on the page No. 2

Quiet & Efficient Plenum Fans Models QEM and QEP plenum fans are designed and engineered to provide superior performance and reliability in commercial or industrial applications. Our products are manufactured with state of the art laser, forming, spinning and welding equipment and endure our quality control testing to ensure trouble free start-up. Plenum fans are designed to handle a variety of commercial and industrial projects. They are designed for unhoused operation which results in a

Summary of the content on the page No. 3

Performance Comparison 9 vs. 12-Blade Wheels Advantages of 12-Blade Wheels performance is adequate, recent industry trends have seen the emergence of 12-blade wheel designs where customers demand higher mechanical efficiency and lower sound levels. Model QEM and QEP plenum fans feature a 12-blade aluminum airfoil construction wheel. As demonstrated in Figure 1, this 12-blade design meets customer needs by providing higher efficiency, lower sound levels as well as lower energy consumption

Summary of the content on the page No. 4

Standard Construction and Features QEM Arrangement 9 Motor on Right QEP Arrangement 3 4

Summary of the content on the page No. 5

Standard Construction and Features 12-Blade Aluminum Airfoil Wheel QEM QEP 11 sizes 18 sizes Available Sizes 12–36 12–73 high efficiency and low sound 12-blade airfoil design. The aluminum wheel reduces start-up 200,000 cfm 3 3 torque requirements as well as shaft loading during 17 m 99 m 12 in. wg Maximum Pressure 1.6 kPa 3 kPa Performance Classes I, II (Partial) I, II, III blades to improve efficiency and reduce vibration. All Arrangements 4, 9 1, 3, 4 wheels are balanced to

Summary of the content on the page No. 6

Optional Construction QEM Protective Cage Inlet Guard Belt Guard Protective Cage QEP Protective Cage Inlet Guard Shaft Guard Belt Guard Protective Cage Structural Isolation Base 6

Summary of the content on the page No. 7

Optional Construction & Accessories Inlet Guard QEM QEP Assembled and mounted low-pressure loss, zinc L 1,000,000 hrs coated guards. 10 Optional Isolation Belt Guard Direct Mount Isolators Optional Optional Custom guarding with two tachometer holes and belt Optional tension inspection door, assembled and mounted. OSHA Compliant Guarding Protective Cage Guard, Inlet Optional Optional Optional Totally enclosed guard to protect personnel from Optional unhoused spinning wheel. Typically

Summary of the content on the page No. 8

Arrangements QEP Arrangement 1 — Horizontal, Motor on Base Sizes 12—73 (shown with optional base & belt guard) QEP Arrangement 3 — Horizontal, Motor on Base Sizes 18—73 (shown with optional base & belt guard) QEP Arrangement 3 — Horizontal, Motor on Frame (Side) Sizes 12—73 QEP Arrangement 3 — Horizontal, Motor on Frame (Top) Sizes 12—73 QEP Arrangement 3 — Vertical, Motor on Frame Sizes 12—54 QEP Arrangement 4 — Horizontal, Direct Drive Sizes 15—60

Summary of the content on the page No. 9

Arrangements QEM Arrangement 9 — Horizontal, Motor on Frame (Side) Sizes 12—36 QEM Arrangement 4 — Horizontal, Direct Drive Sizes 15—36 Available Motor on Frame Positions Left Top Right Available Motor on Base Positions Z W Y X 9

Summary of the content on the page No. 10

System Considerations Air Plenum Design Guidelines Effects of Air Density To assure optimum performance and be able to use Ratings in the fan performance tables and curves of the system effect coefficients below, the following this catalog are based on standard air: clean and dry 3 guidelines should be adhered to in the plenum design: at 70°F at a pressure of 29.92 in. of mercury. A change in elevation, temperature 1. Flexible connections at the inlet are recommended to or the type o

Summary of the content on the page No. 11

System Considerations 3. System effects for plenum discharges must also be Airstream Temperature Variations calculated and added to the design pressure. In a properly designed plenum (see Duct System Effect airstream should be considered: Start-up and normal section), the system effect coefficient (C ) depends o on the orientation of the discharge relative to the fan temperatures, the motor must be sized based the lowest and duct connection (if any). For air plenums wi

Summary of the content on the page No. 12

Direct Drive Selections Direct drive construction offers many advantages for commercial or industrial air handling applications. - Reduced maintenance (no belts and shaft bearings to service) - Compact housing design requires a smaller footprint - Low vibration - Suitable for clean air application (no belt or bearing residue in airstream) Flow Control Options QEP Arrangement 4 width wheel to assist in matching actual fan performance to the desired Horizontal, Direct Drive assist in syste

Summary of the content on the page No. 13

Direct Drive Selections 8 1770 RPM 6 (60 Hz) Static 4 Pressure Model QEM (in. wg) 2 Model QEP 15 16 18 20 22 24 27 30 33 0 1 5 10 50 100 8 1170 RPM 6 (60 Hz) Static 4 Pressure Model QEM (in. wg) 2 Model QEP 16 18 20 22 24 27 30 33 36 40 44 49 54 0 1 5 10 50 100 8 870 RPM 6 (60 Hz) Static Pressure 4 Model QEM (in. wg) 2 Model QEP 22 24 27 30 33 36 4 0 44 49 54 60 0 1 5 10 50 100 8 6 690 RPM Static (60 Hz) Pressure 4 (in. wg) Model QEP 2 27 30 33 36 40 44

Summary of the content on the page No. 14

3510 3586 3900 2400 2991 1453 1905 1 ¾ ½ Plenum Size 12 Plenum Size 12 12 rpm QEP Class I Maximum rpm 2991 hp 5 % WOV QEP Class II Maximum rpm 3064 3 Density 0.075 lb/ft 25 10 3 Density 1.2 kg/m 60% QEM Maximum rpm Note: Model QEM does not utilize class designations. 20 8 2 70% 1½ 15 6 QEP Motor on Frame Limit 184T 80% Minimum Motor Size 1/3 [hp] 15.00 [in.] 10 4 Wheel Diameter 381 [mm] 3 90% (rpm / 2097) [hp] Peak Power 3 (rpm / 2312) [kW] 5 2 cfm / 1.12 [ft/min] Wheel Outlet Velocity 3 m /s

Summary of the content on the page No. 15

4000 3606 3404 3064 3150 2611 1277 2109 1674 3 ½ 5 1 /3 15 10 1½ Plenum Size Plenum Size 15 Plenum Size 15 12 rpm QEP Class I Maximum rpm 2611 hp % WOV 3 Density 0.075 lb/ft QEP Class II Maximum rpm 3404 60% 3 Density 1.2 kg/m 25 10 QEP Class III Maximum rpm 4000 QEM Maximum rpm 3064 70% 20 8 Note: Model QEM does not utilize class designations. QEP Motor on Frame Limit 213T 15 6 80% Minimum Motor Size 1/3 [hp] 15.00 [in.] Wheel Diameter 10 4 381 [mm] 3 90% (rpm / 1842) [hp] Peak Power 3 (rpm /

Summary of the content on the page No. 16

3900 3385 3095 2686 2786 2374 1979 1571 1247 1½ 1 20 3 5 10 15 Plenum Size 16 Plenum Size 16 14 rpm QEP Class I Maximum rpm 2374 hp % WOV 3 Density 0.075 lb/ft QEP Class II Maximum rpm 7½ 60% 30 3 12 Density 1.2 kg/m QEP Class III Maximum rpm 3900 25 10 QEM Maximum rpm 2786 70% Note: Model QEM does not utilize class designations. 20 8 80% QEP Motor on Frame Limit 215T 15 6 Minimum Motor Size 1/3 [hp] 2 16.50 [in.] Wheel Diameter 10 4 419 [mm] 90% 3 (rpm / 1571) [hp] Peak Power 3 ¾ (rpm / 1732)

Summary of the content on the page No. 17

3735 3504 3184 2964 2668 2273 1862 1478 1½ 1 20 25 3 5 10 15 Plenum Size 18 Plenum Size Plenum Size 18 QEP Class I Maximum rpm 2273 35 14 rpm QEP Class II Maximum rpm 2964 hp % WOV 70% 3 Density 0.075 lb/ft QEP Class III Maximum rpm 30 12 3 Density 1.2 kg/m 7½ QEM Maximum rpm 2668 25 10 Note: Model QEM does not utilize class designations. 80% 20 8 QEP Motor on Frame Limit 215T Minimum Motor Size 1/3 [hp] 15 6 18.25 [in.] Wheel Diameter 90% 464 [mm] 10 4 3 2 (rpm / 1291) [hp] Peak Power 3 (r

Summary of the content on the page No. 18

3175 3409 2948 2075 2706 2327 1566 1857 1243 1368 1086 1½ 1 20 25 30 40 3 5 10 15 Plenum Size 20 14 rpm QEP Class I Maximum rpm hp % WOV 3 Density 0.075 lb/ft 3 QEP Class II Maximum rpm 2706 30 12 Density 1.2 kg/m 70% QEP Class III Maximum rpm 3409 7½ 25 10 QEM Maximum rpm 2327 80% Note: Model QEM does not utilize class designations. 20 8 QEP Motor on Frame Limit 254T 15 6 Minimum Motor Size 1/3 [hp] 20.00 [in.] 90% 2 Wheel Diameter 10 4 508 [mm] 3 (rpm / 1086) [hp] Peak Power 3 5 2 (rpm / 11

Summary of the content on the page No. 19

2190 3065 2433 2824 1865 1554 2658 1958 1311 1145 1041 909 3 20 1½ 40 10 Plenum Size 22 Plenum Size 14 rpm QEP Class I Maximum rpm hp % WOV 15 3 Density 0.075 lb/ft 35 QEP Class II Maximum rpm 2433 3 12 Density 1.2 kg/m 70% QEP Class III Maximum rpm 30 10 QEM Maximum rpm 2190 25 Note: Model QEM does not utilize class designations. 80% 8 QEP Motor on Frame Limit 254T 20 Minimum Motor Size 1/2 [hp] 6 15 22.25 [in.] Wheel Diameter 565 [mm] 90% 4 3 10 (rpm / 909) [hp] Peak Power 3 (rpm / 1002) [

Summary of the content on the page No. 20

2480 1960 2178 2744 1670 1365 1005 20 30 25 3 5 50 60 15 Plenum Size 24 14 rpm QEP Class I Maximum rpm 1670 hp 60% % WOV 3 Density 0.075 lb/ft 30 QEP Class II Maximum rpm 2178 3 12 Density 1.2 kg/m QEP Class III Maximum rpm 2744 70% 25 10 QEM Maximum rpm 1960 Note: Model QEM does not utilize class designations. 20 10 8 80% QEP Motor on Frame Limit 256T 7½ 15 6 Minimum Motor Size 3/4 [hp] 24.50 [in.] Wheel Diameter 10 4 622 [mm] 90% 3 (rpm / 798) [hp] Peak Power 3 5 2 (rpm / 880) [kW] 2 cfm /


Alternative user manuals
# User manual Category Download
1 Greenheck Fan 455924 ERV-361 User manual Ventilation Hood 4
2 Greenheck Fan 455924 ERV-581 User manual Ventilation Hood 0
3 Greenheck Fan 455924 ERV-582 User manual Ventilation Hood 0
4 Greenheck Fan 464603 User manual Ventilation Hood 0
5 Greenheck Fan 455924 ERV-521 User manual Ventilation Hood 0
6 Greenheck Fan 455924 ERV-522 User manual Ventilation Hood 2
7 Greenheck Fan 463622 User manual Ventilation Hood 0
8 Greenheck Fan 462102 User manual Ventilation Hood 0
9 Greenheck Fan 461336 User manual Ventilation Hood 0
10 Greenheck Fan 468769 User manual Ventilation Hood 0
11 Greenheck Fan 468502 User manual Ventilation Hood 0
12 Greenheck Fan 471837 User manual Ventilation Hood 0
13 Greenheck Fan 470998 User manual Ventilation Hood 0
14 Greenheck Fan AX User manual Ventilation Hood 1
15 Greenheck Fan Barometric Relief Damper SEBR-10 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0