LG Electronics BG-123A user manual

User manual for the device LG Electronics BG-123A

Device: LG Electronics BG-123A
Category: Air Conditioner
Manufacturer: LG Electronics
Size: 12.82 MB
Added : 11/9/2013
Number of pages: 39
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for LG Electronics BG-123A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with LG Electronics BG-123A.

For your convenience

If looking through the LG Electronics BG-123A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LG Electronics BG-123A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LG Electronics BG-123A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LG Electronics BG-123A User manual - Online PDF
Advertisement
« Page 1 of 39 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LG Electronics BG-123A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LG Electronics BG-123A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ROOM AIR CONDITIONER
SERVICE MANUAL
CAUTION
- BEFORE SERVICING THE UNIT,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
- ONLY FOR AUTHORIZED SERVICE
MODEL: BG-81A/LT0810CR/LT080CSG
BG-101A/LT1010CR/LT1030CR
LT1210CR/LT121CSG/BG-123A
LT1230CR/LT1430CR

Summary of the content on the page No. 2

CONTENTS 2.4 REFRIGERATION CYCLE.................................10 1. PREFACE 2.4.1 CONDENSER ......................................10 1.1 SAFETY PRECAUTIONS ...............................2 2.4.2 EVAPORATOR ....................................10 1.2 INSULATION RESISTANCE TEST.................2 2.4.3 CAPILLARY TUBE...............................10 1.3 SPECIFICATIONS ..........................................3 1.4 FEATURES .....................................................5 3. INSTALLATION 1.

Summary of the content on the page No. 3

1.3 SPECIFICATIONS 1.3.1 FOR BG-101A/LT1010CR/LT121CSG/LT1210CR /LT0810CR/LT080CSG/BG-81A MODELS BG-101A/LT1010CR LT121CSG/LT1210CR LT0810CR/LT080CSG REMARK ITEMS /BG-81A POWER SUPPLY 1Ø, 115V, 60Hz COOLING CAPACITY (Btu/h) 9,800 11,500 8,000 INPUT (W) 1,110 1,310 830 RUNNING CURRENT (A) 10.2 12.0 7.5 E.E.R (Btu/w.h) 8.8 8.8 9.6 REFRIGERANT (R-22) CHARGE(g) 470g(16.6OZ) 500g(17.6OZ) 545g(19.2OZ) OPERATING INDOOR (°C) 26.7(DB) 19.4(WB) TEMPERATURE OUTDOOR (°C) 35(DB) 23.

Summary of the content on the page No. 4

1.3.2 FOR LT1030CR/LT1230CR/BG-123A/LT1430CR MODELS LT1030CR LT1230CR/BG-123A LT1430CR REMAR ITEMS 1Ø, 230/208V, 60Hz POWER SUPPLY 10,000/9,800 11,500/11,200 13,200/12,800 COOLING CAPACITY (Btu/h) 1,060/1,040 1,310/1,270 1,550/1,500 INPUT (W) 4.7/5.2 6.0/6.4 7.1/7.6 RUNNING CURRENT (A) 9.4/9.4 8.8/8.8 8.5/8.5 E.E.R. (Btu/W.h) 480g(16.9OZ) 485g(17.1OZ) 545g(19.2OZ) INDOOR (°C) OPERATING TEMPERA-TURE 26.7(DB) 19.4(WB) OUTDOOR (°C) 35(DB) 23.9(WB) REFRIGERANT (R-22) CHARGE

Summary of the content on the page No. 5

1.4 FEATURES • Designed for cooling only. • Side air-intake, side cooled-air discharge. • Built in adjustable THERMISTOR and THERMOSTAT. • Powerful and quiet cooling. • Top-down chassis for the simple installation and service. • Washable one-touch filter. • Compact size. 1.5 CONTROL LOCATIONS 1.5.1 COOLING ONLY MODEL • OPERATION FAN SPEED • Every time you push this button, it advances the setting as follows: {High  Low  Med  High} REMOTE CONTROL SIGNAL RECEIVER ' Cool F F1 LOW F2 MED F3 HIGH

Summary of the content on the page No. 6

C l ' oo F F2 1 3L ME H OIG W DH F En S earv ge yr F Fan TEMP Timer MODE TIMER FAN POWER SPEED Cool F1 LOW 'F F F2 3 M HE IG DH Ener Saver gy Fan Timer TEMP MODE TIMER FAN POWER SPEED 2. DISASSEMBLY INSTRUCTIONS — Prior to disassembling the unit, make sure that the POWER is off and the power cord is unplugged from the wall receptacle. 2.1 MECHANICAL PARTS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the

Summary of the content on the page No. 7

Cool F1 LO W ' F En erg y F F 2 3 M H IG ED H Saver Fan Timer TEMP MODE TIMER FAN POWER SPEED Coo l F1 LOW 'F Energy F F 2 3 M H I E G DH Saver Fan T imer TEMP MODE TIMER FAN POWER SPEED Cool F1 LOW ' F Energy F F2 3 M H E G IDH Saver Fan Timer TEMP MODE TIMER FAN POWER SPEED ' EC no ero gly F F F 1 2 3 L M H OE W IG DH F Saver Fan Timer TEMP FAN MODE TIMER SPEED POWER 2.2 AIR HANDLING PARTS 2.2.1 ORIFICE, AND TURBO FAN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabine

Summary of the content on the page No. 8

Cool 'F F1 LO F2 MED W Energy F3 HIGH Saver Fan TEMP Timer FAN MODE TIMER SPEED POWER 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Fig. 9) 3. Re-install the components by referring to the removal procedures, above. 2.3 ELECTRICAL PARTS 2.3.1 MOTOR 1. Remove the cabinet. (Refer to section 2.1.2) Figure 9 2. Remove the clamp cord and disconnect the wire housing in control box. (Refer to section 2.1.3) 3. Remove the turbo fan. (Refer to section 2.2.2) 4. Remo

Summary of the content on the page No. 9

Cool 'F F1 LOW F2 MED Energy F3 HIGH Saver Fan TEMP Timer FAN MODE TIMER POWER SPEED 2.3.4 POWER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Unfold the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the Base pan. 4. Disconnect 2 receptacles. 5. Remove a screw which fastens the clip cord. 6. Pull the power cord. (See Fig. 13) 7. Re-install the components by referring to the removal procedure, above. (Use only one ground-marked hole, , for ground

Summary of the content on the page No. 10

Cool 'F Energy F F F3 1 2 ME LHIGH OW D Saver Fan Timer TEMP FAN MODE TIMER SPEED POWER 2.4 REFRIGERATION CYCLE CAUTION TM Discharge the refrigerant system using a Freon Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before TM venting the Freon . Leave the valve in place after servicing the system. 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the brace. (Refer to section 2.2.1) 3. Remove the 7 screws which fast

Summary of the content on the page No. 11

NOTES — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to 6. Recharge as follows : TM discharge the refrigerant system using a Freon 1) Refrigeration cycle systems are charged from the recovery System. High-side. If the total charge cannot be put If there is no valve to attach the recovery system, in the High-side, the balance will be put in the install one (such as a WATCO A-1) before venting suction line through the access valve which you TM the F

Summary of the content on the page No. 12

Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. Figure 17A-Pulling Vacuum Figure 17B-Charging —12— COMPOUND GAUGE CONDENSER (HIGH PRESSURE SIDE) MANIFOLD GAUGE B A CAPILLARY TUBE SEE INSETS BELOW EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR LOW HI A B B A EXTERNAL VACUUM PUMP CHARGING CYLINDER C

Summary of the content on the page No. 13

3. INSTALLATION INSTALLATION HARDWARE 3.1 INSTALLATION REQUIREMENTS If you use an existing wall sleeve, you should measure its 2 4 1 dimensions. 5 Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good 2 Size options 6 structural condition and have a compatible rear grille in order 8 to securely attach the new air conditioner. (FIG. 18A) With the FRIEDRICH USC sleeve, yo

Summary of the content on the page No. 14

NOTE: All wall sleeves used to mount the new Air 3.2 INSTALLATION Conditioner must be in sound structural condition and have a CAUTION rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner. Installing the FRIEDRICH USC sleeve ensures Remove old air conditioner from existing wall sleeve. optional performances of the unit. 2 If you decide to keep the existing wall sleeve, you have Clean the interior of an existing sleeve. to redirect the louver

Summary of the content on the page No. 15

PROCEDURE A If you are using the new sleeve (optionally Install the new unit into the wall sleeve. 4 1 supplied with your unit),skip to step 3. Toassembletrim,tpthetabofeachpiece Otherwise, install the plastic grille from the kit. 5 into the slot of the other piece as shown below. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below. inside of the wall sleeve at the

Summary of the content on the page No. 16

Remove the backing from the Vertical Insulation PROCEDURE B 4 9 3 3 strip 15 / x1 / x1 / and attach that to the 16 8 8 Redirect the louvers at the back of the wall inside right of the sleeve as shown below. 1 sleeve to 60° angle as shown in the FIG 8. The Remove the backing from the Around Insulation use of pliers is recommended. 1 3 25 strip 67 / x 1 / x / and attach that to the 8 8 32 inside front of the sleeve as shown below. 3 3 7 7 // " " Indoor Indoor Outdoor Outdoor 32 32 60 60°° 60 60°°

Summary of the content on the page No. 17

PROCEDURE B CONTINUED Remove the backing from the support blocks and attach 6 them to the inside of the wall sleeve as shown FIG 29. Slide the baffle into slots of the support blocks. 3 (7 / ") 32 Wall Wall Baffle Sleeve Front Support Block FIG. 29 Install the new unit into the wall sleeve. 7 Assemble trim as described in Step 6, 8 Procedure A. CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To preve

Summary of the content on the page No. 18

Remove the backing from the Horizontal Insulation strip 3.5 PROCEDURE C 4 7 3 3 23 / x 1 / x 1 / and attach that to the inside right of the 32 8 16 Redirect the louvers at the back of the wall sleeve to 60° sleeve as shown below. Remove the backing from the 1 27 3 3 angle as shown in the FIG 30. The use of pliers is Around Insulation strip 59 / x 1 / x 1 / and attach that 32 8 8 recommended. to the inside front of the sleeve as shown below. 13 7 / " 16 Indoor Outdoor 60° 60° Rear Louvers Around

Summary of the content on the page No. 19

Parts and Installation PROCEDURE C CONTINUED CAUTION To achieve rearward slope for unit draining, 7 13 • Air conditioners covered in this manual pose an remove the backing from the 11 / "shim 16 excessive weight hazard. Two or more people are strips and attach them as shown below in Fig. 37. The higher portion of shim is to be placed needed to move and install the unit. in front of the rib on the base of wall sleeve. To prevent injury or strain, use proper lifting and carrying techniques when mo

Summary of the content on the page No. 20

4. TROUBLESHOOTING GUIDE 4.1 OUTSIDE DIMENSIONS 3 24" 20- /32" (499mm) (610mm) Cool F1 LOW 'F F3 HIGH F2 MED Ener Saver gy Fan Timer TEMP MODE TIMER FAN POWER SPEED 4.2 PIPING SYSTEM CONDENSER COILS FAN CAPILLARY TUBE MOTOR COMPRESSOR TURBO FAN EVAPORATOR COILS Following is a brief description of the important components and their functions in the refrigeration system. Refer to Fig. 41 to follow the refrigeration cycle and the flow of the refrigerant in the cooling cycle. ROOM AIR CONDITIONE


Alternative user manuals
# User manual Category Download
1 LG Electronics 3828A20025V User manual Air Conditioner 45
2 LG Electronics -BKE 7630 NS G User manual Air Conditioner 18
3 LG Electronics 3828A20025U User manual Air Conditioner 11
4 LG Electronics 230/208V User manual Air Conditioner 23
5 LG Electronics 6710 YS User manual Air Conditioner 28
6 LG Electronics 3828A22005P User manual Air Conditioner 13
7 LG Electronics A3UH363FA0, A3UC363FA0, AMNH093D4A0, AMNC093D4A0, AMNH123DEA0, AMNC123DEA0, AMNH093APM0, AMNC093APM0, AMNH123APM0, AMNC123APM0 User manual Air Conditioner 1
8 LG Electronics 6720 YS User manual Air Conditioner 0
9 LG Electronics User manual Air Conditioner 7
10 LG Electronics A2UH243FA0(LMU240HE) User manual Air Conditioner 2
11 LG Electronics 3828A30087S User manual Air Conditioner 1
12 LG Electronics A2UC243FA0 (LMU240CE) User manual Air Conditioner 0
13 LG Electronics AMNC093APM0(LMAN090CNS) User manual Air Conditioner 0
14 LG Electronics AMNH123APM0(LMAN120HNS) User manual Air Conditioner 0
15 LG Electronics AMNH093APM0(LMAN090HNS) User manual Air Conditioner 0
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21