Hisense Group KFR 33GWE user manual

User manual for the device Hisense Group KFR 33GWE

Device: Hisense Group KFR 33GWE
Category: Air Conditioner
Manufacturer: Hisense Group
Size: 0.24 MB
Added : 12/29/2013
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hisense Group KFR 33GWE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hisense Group KFR 33GWE.

For your convenience

If looking through the Hisense Group KFR 33GWE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hisense Group KFR 33GWE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hisense Group KFR 33GWE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hisense Group KFR 33GWE User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hisense Group KFR 33GWE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hisense Group KFR 33GWE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

- -
K KF FR R 3 33 3G GW WE E
- -
K KF FR R 2 28 8G GW WE E
- -
K KF FR R 2 25 5G GW WE E
- -
K KF FR R 2 21 10 01 1G GW WE E
- -
K KF FR R 3 32 20 01 1G GW WE E
S SP PL LIIT T T TY YP PE E A AIIR R C CO ON ND DIIT TIIO ON NE ER R
I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L
Hisense Corporation

Summary of the content on the page No. 2

This air conditioner provides with cooling, heating, and drying functions. Details of the functions are below; refer to these descriptions when using the air conditioner. Compact Size Air Sweep Control This model is smaller than its predecessors and This function moves a flap up and down in the air yet offers the same capabilities. outlet, directing air in a sweeping motion around the room and providing comfort in every corner. Microprocessor Controlled Operation

Summary of the content on the page No. 3

Contents Pardon not to inform you if the contents of the manual changes. Page Alert symbol 1 Caution statements 2 Composition of the air conditioner 3 Operation guide 8 Care and cleaning 16 Tips for energy saving 18 Troubleshooting 18 Schematic diagram

Summary of the content on the page No. 4

Caution Statements 1.We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the installation WARNING instructions provided with the unit. 2.Before installation, check if the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. WARNING 3.Do not install the air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenh

Summary of the content on the page No. 5

Composition of the Air Conditioner 1.Diagram of Structure Air intake grille INDOOR UNIT Air outlet Drain hose Remote control Refrigerant tubes unit OUTDOOR UNIT Air outlet This air conditioner consists of an indoor unit and an outdoor unit. You can NOTE control the air conditioner with the remote control unit. Air from the room is drawn into this section and passes Air Intake through air filters which remove dust. Conditionedairisblownoutoftheairconditionerthrough Air Outlet thea

Summary of the content on the page No. 6

2.Introduction of the Indoor ControI Unit INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp IMPORTANT: POWER HI POWER HIGH POWER TIMER Avoid using radio equipment lamp OPERATING such as mobile phone near (within 1m) the indoor unit. Some radio equipment may ON/OFF cause maIfunction of the unit. If the troubIe happens, dis- connect power and restart the air conditioner after a few REMOTE CONTROL receiver ON/OFF button minutes. REMOTE CONTROL

Summary of the content on the page No. 7

3.Introduction of Display Displayed when setting temperature S SE ET T T TE EM MP P Displayed when transmitting data AUTO C Displayed when temperature is shown Displayed when temperature setting is at the upper or lower allowable limits 1HOUR Displayed when Night Setback is Displayed when one-hour running OFF timer is enable Displayed when main unit sensor is in HOUR AUTO use ON Displayed when setting timer AUTO OFF Symbols (1) Operation mode (3) Set temperature 16-30 When s

Summary of the content on the page No. 8

4.Introduction of the Remote control Unit SENSOR Transmitter SET TEMP AUTO C 1 1H 1HOU OUR R x HOUR HOUR AUTO Display AUTO TEMP 1HR ON/OFF 1 HR. TIMER button TEMP.setting button HIGH POWER HIGH POWER button ON/OFF button FLAP MODE FLAP button MODE selector button ON OFF FAN SPEED FAN SPEED selector button TIMER ON/OFF button SLEEP CANCEL SET NIGHT SETBACK button BATTERY TIMER SET/CANCEL A/C SENSOR ACL button A/C SENSOR button ACL button (Cover closed) Battery compartment (pull off the

Summary of the content on the page No. 9

Remote Control Unit(continued) TIMER ON button :The air conditioner starts at the set time. TIMER OFF button :The air conditioner stops at the set time. TIMER SET/CANCEL button This button is used to set/cancel the time at which you wish the air conditioner to go on or off. MODE selector button Use this button to select AUTO, HEAT, DRY or COOL mode. (AUTO) AUTO :When this setting is selected, the air conditioner calculates the difference between the set

Summary of the content on the page No. 10

Operation Guide HOW TO INSTALL BATTERIES 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction m arked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. ACL button A Replace the batteries when the remote control unit's display fails to light, NOTE or when the remote control unit cannot be used to change the air ! ,

Summary of the content on the page No. 11

Operation with the Remote Control Unit(continued) C AUTO AUTO 1HR TEMP ON/OFF STEP 3 HIGH STEP 2 POWER FLAP MODE STEP 5 STEP 1 FAN ON OFF SPEED STEP 4 SET CANCEL SLEEP BATTERY A/C SENSOR ACL Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is NOTE in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. Press

Summary of the content on the page No. 12

Adjusting the Fan Speed A. Automatic AUTO Simply set the FAN SPEED selector to the position. AUTO A microcomputer in the air conditioner automatically controls the fan speed when the mode is selected. When the air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomputer which then automatically switches the fan speed to the most suitable level. Cooling mode: When difference bet

Summary of the content on the page No. 13

Adjusting the Airflow Direction 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. When the humidity is high, the vertical vanes should be in the front CAUTION position during the cooling or dehumidifying operation. If the vertical ! vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down. 2. Vertical The vertical airflow can be adjusted by m

Summary of the content on the page No. 14

Night Setback / Simultaneous Use Energy Saving Night Setback Mode Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark appears in the display. T o release the night setback function, press the SLEEPbutton again. C NOTE This function loses in automation or airflow mode. AUTO AUTO A.In Cooling and DRY Mode: When the night setback mode is selected, the air conditioner 1HR TEMP ON/OFF automatically raises the temperature,

Summary of the content on the page No. 15

Using the 12-Hour ON and OFF Timer 1.TIMER ON mode After the length of time set for TIMER ON elapses, the unit begins operating. (Example) The display depicted at left indicates that the air conditioner will begin operating in three hours. Setting Procedures: C Press the MODE button and set the desired operation mode and STEP 1 HO HOUR UR press the ON/OFF operation button. STEP 2 Press the timer ON button to set the time at which you want operation to begin. The time can be set for

Summary of the content on the page No. 16

Using the 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. 1HOUR 1HOUR The indicator in the display indicates that this function is operating. Setting procedure: C Regardless of whether the unit is operating or stopped, press the 1 HR .TIMER button. Appears in the display. 1HOUR 1HOUR 1H 1HOU OUR R AUTO AUTO Cancellation procedure: 1HR TEMP ON/OFF Press the

Summary of the content on the page No. 17

Special Remarks Heating ( ) Operation Heating performance Because this air conditioner heats a room by drawing on the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance in conjunction with it. When the outdoor temperature is low, frost or ice may from in the heat exchanger Defrosting coil,

Summary of the content on the page No. 18

Operation without the Remote Control Unit If you have lost the remote control unit or it has trouble, follow the steps below. INDOOR UNIT 1.When the air conditioner is not running If you want to turn on the air conditioner, pressing the ON/OFF button once. HI POWER HIGH POWER POWER TIMER lamp 2.When the air conditioner is running OPERATING If you want to turn off the air conditioner, pressing the ON/OFF button once. ON/OFF ON/OFF button Pressing buttons cannot last too long time, or

Summary of the content on the page No. 19

Care and Cleaning (continued) Anti-Mold Filter The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. How to remove the 1.Grasp both ends of the air intake grille and pull it out and up. anti-mold filter 2.Push the anti-mold filter up slightly, and then pull it down. Air intake grille Anti-mold filter Anti-Mold Filter Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, Cleaning wash the filter in lukewarm

Summary of the content on the page No. 20

Tips for Energy Saving Do not Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. Always try to keep the air filter clean. (Refer to Care and Cleaning .)A Do clogged filter will impair the performance of the unit. To


Alternative user manuals
# User manual Category Download
1 Hisense Group KF 346GWE User manual Air Conditioner 332
2 Hisense Group KFR 2601GW/BPE User manual Air Conditioner 98
3 Hisense Group KFR 28GWE User manual Air Conditioner 46
4 Hisense Group KFR 3201GWE User manual Air Conditioner 27
5 Hisense Group KFR 2101GWE User manual Air Conditioner 47
6 Hisense Group KFR-3208GW User manual Air Conditioner 42
7 Hisense Group KF-5002GWE User manual Air Conditioner 45
8 Hisense Group KFR 2801GW/BPE User manual Air Conditioner 41
9 Hisense Group KFR 25GWE User manual Air Conditioner 148
10 Sony SU-PW2 User manual Air Conditioner 12
11 Sony CV-P12PX User manual Air Conditioner 3
12 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
13 Sony VGN-BX500 User manual Air Conditioner 1
14 Philips 190S5 User manual Air Conditioner 21
15 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7