Summary of the content on the page No. 1
Portable Air Conditioner
OWNER’S MANUAL
Read these instructions before use
Model: MN12CES / MN10CESWW
Voltage rating: 120V~60Hz
Power rating : 1100W (MN12CES)
Power rating : 900W (MN10CESWW)
Customer Support : 1-800-474-2147
For product inquiries or support : www.honeywellportableac.com Made in China
8
Summary of the content on the page No. 2
INDEX Read all instructions carefully before setting up and operating the unit. Keep this instruction manual for future reference. This manual is designed to provide important information needed to setup, operate, maintain and troubleshoot your portable air conditioner. Failure to follow these instructions may void the warranty. SECTION PAGE 1. INDEX .............................................................................................................. 1 2. THANK YOU......................
Summary of the content on the page No. 3
THANK YOU Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner. r. Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air outlet hose sends heat outside. The air conditioner includes a window venting kit. No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air
Summary of the content on the page No. 4
USER TIPS To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation. Cooling and Dehumidifying Operation Fan Operation Important : Before installing the unit, place it UPRIGHT for 20 minutes before use to allow the refrigerant to stabilize. • Follow installation instructions to set up the unit. • Plug the unit into a pro
Summary of the content on the page No. 5
SAFETY READ AND SAVE THESE INSTRUCTIONS Improper handling can cause serious damage to the appliance. WARNING 1. DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service agent. 2. DO NOT cover the air intake and exhaust when in use. 3. This appliance is not intended for use by children. Children should be supervised and should not play on or around the appliance. 4. DO NOT place objects on or
Summary of the content on the page No. 6
SAFETY 8. DO NOT run the power cord under carpeting and rugs. 9. Use caution to prevent tripping on cord. 10. DO NOT use in areas where gasoline, paint or other flammable goods are stored. 11. Basic safety precautions should always be followed when using electrical appliances. 5
Summary of the content on the page No. 7
PARTS DESCRIPTION 6 7 2 1 3 5 10 11 8 9 4 1. Control Panel (Incl. Signal Receptor) 7. Back Grill 2. Air Outlet 8. Lower Drain Plug 3. Handle 9. Power Supply Cord 4. Casters 10. Exhaust Hose Connector 5. Upper Drain Plug 11. Remote Control 6. Air Filter Installation Kit : 4 1 2 3 1. Window Bracket Kit............................. 1 Set x 1 x 1 x 2 2. Window Bracket Panel Adapter.......... 1 Piece 3. Plastic Pin........................................... 2 Pieces x 1 4. Hose Connector
Summary of the content on the page No. 8
INSTALLATION 1 Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends. = 2 Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at the desired position. Note : Do not install the window bracket to your window. This step is Plastic Pin required only to adjust it to the size of your window. The bracket should be removed from the window after the size is adjusted. Plastic Pin 3 Connect
Summary of the content on the page No. 9
INSTALLATION 4 Connect the window bracket to the opposite end of the plastic hose. Ensure that all connections are tight and installed properly. 5 Connect the window bracket to the window. 6 The Portable Air Conditioner is now ready to use. 8 8 8
Summary of the content on the page No. 10
INSTALLATION Note: 1. The supplied exhaust hose can be extended from 12 inches (1 foot) to 47 inches (3.9 feet). 2. Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off. 20” NOT RECOMMENDED RECOMMENDED Warning: • The length of the exhaust hose is determined by the product specifications. Do not replace or lengthen it as this could cause the unit to malfunction. • Make sure the back of the unit is at least 20 i
Summary of the content on the page No. 11
USE & OPERATION Touch Screen Control Panel Warning Light (when flashing) Timer Control Power Control Fan Speed Control Timer / Temperature Mode Control Set Controls Power Control Fan Speed Control The Power Control turns the unit on and off. 3 settings: High, Medium and Low. Mode Control Timer Control Auto turn off: 3 settings: Cool, Dehumidify and Fan With machine in running mode, press timer button to select the A light will indicate which setting is currently being used. number of hours you
Summary of the content on the page No. 12
USE & OPERATION Remote Control The functions work the same as the portable air conditioner’s touch controls. All key functions can be accessed from the remote control. Temperature / Timer Set Control • Used for adjusting the timer and temperature. • The default display is room Power Control temperature. ON / OFF • When “ “ or ““ key is pressed in cool mode, the set temperature is displayed and may be adjusted. After 10 seconds the display will revert Fan Speed Control back t
Summary of the content on the page No. 13
USE & OPERATION Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with ‘‘+’’ and ‘‘-’’ pointing in the proper direction. Caution • Use only two AAA or IEC R03 1.5V batteries. • Remove the batteries if the remote control is not in use for a month or longer. • All batteries should be replaced at the same time, do not mix with old batteries. • Properly dispose of used batteries. 12
Summary of the content on the page No. 14
CLEANING & MAINTENANCE Appliance Maintenance: 1. Turn off the appliance before disconnecting the power supply. 2. Always clean the appliance with a soft dry cloth. Air Filter Maintenance: The air filter should be cleaned every two weeks. Clean it as follows: 1. Turn off the appliance and remove the air filter. (refer to page 5, #6) 2. Rinse it in lukewarm water. After cleaning, dry in a shaded and cool place, then reinstall. Maintenance After Use: 1. If the appliance will not be used for a long
Summary of the content on the page No. 15
WATER CONDENSATION DRAINAGE Water Condensation Drainage When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (refer to page 10). This warning light indicates that the water condensation needs to be drained using the following procedures: Manual Draining Water may need to be drained in high humidity areas 1. Unplug the unit from power source. 2. Place a shallow pan under the lower drain plug. See diagram. Lower 3. Remove the lower
Summary of the content on the page No. 16
TROUBLESHOOTING GUIDE The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot. Problem Possible Cause Solution • No electricity. • Check for power. • Batteries in the remote control need • Change remote control batteries. to be replaced. The air conditioning • The power cord is not properly • Remove and reconnect the power unit does not start
Summary of the content on the page No. 17
TECHNICAL SPECIFICATIONS Description of Product Portable Air Conditioner Portable Air Conditioner Model MN12CES MN10CESWW Voltage/Frequency 120 V~ 60 Hz 120 V~ 60 Hz Power Consumption 1100W 900W Cooling capacity 12000 BTU 10000 BTU Dehumidifying capacity 70 pints/24 hours 68 pints/24 hours Refrigerant Type R-410A R-410A Timer 24 hour (ON / OFF) 24 hour (ON / OFF) 15.2 X 18.1 X 29.3 inches 15.2 X 18.1 X 29.3 inches Dimensions (W) x (D) x (H) (inches) Weight (Kg) 68.3 lbs (31 Kg) 63.9 lbs (29 K
Summary of the content on the page No. 18
SERVICE AND WARRANTY 5-YEAR LIMITED WARRANTY 1st year parts and labor. 5 years on all parts of the sealed system, consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. A. This warranty does not apply to any damage resulting from abusive, unreasonable use or damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. JMA NORTH AMERICA LLC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES
Summary of the content on the page No. 19
SERVICE AND WARRANTY D. Please read the Instruction Manual carefully before setting up or using this product. If you believe this product to be suffering from a manufacturing fault, or if you have inquiries about this product, please contact our Customer Support: CUSTOMER SUPPORT JMA North America LLC Ramsey, New Jersey 07446 Phone: 800-474-2147 Email: info@jmana.us When contacting our Customer Support, please have the information below along with the proof of purchase. All warranty requests mus
Summary of the content on the page No. 20
MN12CES&MN10CESWW_IM_Eng_USA_10 January 2013 Distributor: © 2013 AirTek Int’l Corp. Ltd. JMA North America LLC (JMATEK Int’l Group of Companies) The Honeywell Trademark is used under license from Ramsey New Jersey 07446 Honeywell International Inc. Customer Support: 1-800-474-2147 Honeywell International Inc. makes no representation or E-mail: info@jmana.us warranties with respect to this product. This product is Manufactured by Airtek International www.honeywellportableac.com Corporation Limi