Heat Controller Inc.EKTH user manual

User manual for the device Heat Controller Inc.EKTH

Device: Heat Controller Inc.EKTH
Category: Air Conditioner
Manufacturer: Heat Controller
Size: 0.66 MB
Added : 7/24/2013
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat Controller Inc.EKTH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat Controller Inc.EKTH.

For your convenience

If looking through the Heat Controller Inc.EKTH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat Controller Inc.EKTH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat Controller Inc.EKTH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat Controller Inc.EKTH User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat Controller Inc.EKTH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat Controller Inc.EKTH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HEAT CONTROLLER, INC.
Installation Operation
and Maintenance
Packaged Terminal
AC/Heat Pumps
EKTC/EKTH


M Series

HEAT CONTROLLER, INC.
1900 Wellworth Ave., Jackson, Michigan 49203 • Ph. 517-787-2100 • Fax 517-787-9341 • www.heatcontroller.com
THE QUALITY LEADER IN CONDITIONING AIR

Summary of the content on the page No. 2

with Smart Control ` PACKAGE TERMINAL AIR CONDITIONER/HEAT PUMP Made in USA ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is more

Summary of the content on the page No. 3

Contents Unit Features ........................................................................................... 3 General Information ................................................................................ 5 Installation Instructions .......................................................................... 6 Wiring ....................................................................................................... 8 Operating Instructions..........................................

Summary of the content on the page No. 4

Unit Features This unit has many features which are different than those found on conventional PTAC units. The servicer must be familiar with these features in order to properly service the unit. • LCDI or AFCI Power Cords - Underwrites Laboratories and the • Indication LEDs - The touch pad has LEDs that corre- National Electric Code (NEC) now require power cords that spond to fan operation and to indicate unit status. The sense current leakage and can open the electrical circuit to the LEDs ne

Summary of the content on the page No. 5

Unit Features • Energy Management System Features Temperature Setback - This option can save energy dollars for unrented or unoccupied rooms by automatically setting back the operational temperatures. This mode of operation is selected through the configuration routine (see Configu- ration Settings section). If none of the keys on the control pad have been pressed for an 18-hour period. The unit will automatically go into a 3-stage setback routine; after 30 minutes, a 1 degrees setback; after 3

Summary of the content on the page No. 6

General Information TRANSPORTATION DAMAGE All units are securely packed in shipping containers tested according to International Safe Transit Association specifications. The carton must be checked upon arrival for external damage. If damage is found, a written request for inspection by the carrier’s agent must be made immediately. In the event of damage, the consignee must: 1. Make notation on delivery receipt of any visible damage to shipment or container. 2. Notify carrier promptly and request

Summary of the content on the page No. 7

Installation Instructions To ensure that the unit operates safely and efficiently, it must be installed, operated and maintained according to these installation and operating instructions and all local codes and ordinances or, in their absence, with the latest edition of the National Electric Code. The proper installation of this unit is described in the following sections. Following the steps in the order presented should ensure proper installation. WARNING Rear Closure Panel TO PREVENT PROPERT

Summary of the content on the page No. 8

Installation Instructions 2. Pull the bottom of the cabinet front away from the chassis until SLEEVE INSTALLATION the retaining clips disengage. NOTE: If front is secured with In order for condensate water to drain properly inside the unit, the screws, remove front mounting screw, then follow front re- sleeve must be installed properly: moval procedure. • Level from right to left. • A slight downward pitch from the indoor side to the outdoor side as shown below. Refer to the Installation Instr

Summary of the content on the page No. 9

Installation Instructions 4. Secure the chassis to the wall sleeve using three screws on Screws Wall Sleeve each side of the chassis to ensure a proper seal between the (3 on each chassis and the wall sleeve. The screws are supplied in a side of unit) plastic bag attached to the power cord. IMPORTANT NOTES: 1. The unit is equipped with a rubber grommet mounted com- pressor. These grommets are factory set and require no ad- justment. 2. If a standard subbase is used, be sure the right hand subba

Summary of the content on the page No. 10

Wiring VOLTAGE MEASUREMENTS Power Cord Requirements 230/208 Volt Units 265 Volt Units Once the unit is properly wired, measure the unit supply voltage. Heater Size Power Cord Power Cord Voltage must fall within the voltage utilization range given in (kW) Rating (amp) Rating (amp) Table 2. 1.5 15 20 2.5 15 20 Operating Voltage 3.5 20 Not Applicable Unit Voltage Voltage Utilization Range 3.7 Not Applicable 20 Rating Minimum Maximum 5.0 30 30 230/208 197 253 265 238 292 Table 1 - Power Cord Require

Summary of the content on the page No. 11

Operating Instructions SW2 AUXILIARY REMOTE THERMOSTAT P10 P11 DS1 DS2 MS1 MS2 EH IN LS FD1 FD2 TF- TF+ C R GL W2 Y/W1 B GH P13 P12 M1 M2 COM A COM B ON / OFF IAT MASTER SWITCH BLACK Control Board User Inputs* *NOTE: The PTAC Wire Harness Kit (PWHK01C) is required for the auxiliary or remote thermostat options. installation of a front desk switch. The following figure shows a ADDITIONAL CONTROL INPUTS wiring schematic for connecting the front desk switch to the unit. The control inputs shown

Summary of the content on the page No. 12

Operating Instructions Vent Vent Open Closed No holes are permitted Vent Door Lever Positions in chassis basepan or wallsleeve when routing low voltage wire. Route the Hydronic Heat Installations low voltage wires through To avoid the risk of freezing the steam or water coil during the indention on the front of the basepan. prolonged shut down periods, the vent door must be left closed Low Voltage Wires Routing when the outdoor temperature might fall below freezing. VENT CONTROL AIR DISCHARGE GR

Summary of the content on the page No. 13

Operating Instructions 3. Remove the four (4) nuts which secure the discharge air grille • Concealed pipes and chimneys to the cabinet front. • Unheated (uncooled) areas behind the thermostat, such as an outside walls Consult the instruction sheet packaged with the thermostat for further details on mounting and operation. REMOTE THERMOSTAT OPERATION Approved thermostats vary slightly in construction and, with few exceptions, are operated similarly. The following operational description pertains

Summary of the content on the page No. 14

X1 X1 O O B** B** Y Y W1 W1 W2 W2 G* G* R R Operating Instructions 3. Run 6 to 8 wires during initial installation. Tape or cap off any unused wires. AUXILIARY REMOTE THERMOSTAT DS1 DS2 MS1 MS2 EH IN LS FD1 FD2 TF- TF+ C R GL W2 Y/W1 B GH Control Board Connections Thermostat Connections Wiring Schematic for Straight Cool Unit *NOTE: For high speed fan operation, connect “G” to “GH”. AUXILIARY REMOTE THERMOSTAT DS1 DS2 MS1 MS2 EH IN LS FD1 FD2 TF- TF+ C R GL W2 Y/W1 B GH Control Board Connecti

Summary of the content on the page No. 15

Maintenance and Cleaning WARNING TO AVOID THE RISK OF PROPERTY DAMAGE, ELECTRICAL SHOCK OR PERSONAL INJURY, CLEAN AIR FILTERS AND COILS REGULARLY. CLOGGED ` OR SEVERLY RESTRICTED FILTERS OR COILS REDUCE AIRFLOW WHICH CAN CAUSE DRASTIC EFFICIENCY LOSS AS WELL AS SEVERE COMPONENT DAMAGE TO COMPRESSORS, ELECTRIC HEATER OR FAN MOTOR. IN EXTREME CASES, CLOGGED FILTERS AND/OR COILS MAY CREATE A FIRE HAZARD AND WILL VOID THE WARRANTY. WARNING SOME LOCAL CONDITIONS AND ENVIRONMENTS CAN CAUSE FUNGI AND O

Summary of the content on the page No. 16

Maintenance and Cleaning Cabinet Front Basepan and Condenser Coil The cabinet front and discharge air grille can be cleaned with a CAUTION water dampened cloth . Under no circumstances should hydro- carbon-based cleaners (e.g. acetone, benzene, naphtha gaso- DO NOT USE COMMERCIAL GRADE COIL CLEANERS. SOME OF THESE CLEANERS MAY CONTAIN ETHYLENE DIAMINE TETRACETIC ACID (EDTA) line, etc.) be used to clean the front or air grilles. Use care when WHICH CAN SHORTEN THE LIFE OF THE CONDENSER COIL. clea

Summary of the content on the page No. 17

Obtaining Service In the event this unit requires repair or servicing beyond what is covered in this manual, contact an authorized service organization. To obtain an authorized servicer, contact your sales representative or agency. Normal Operating Sounds and Conditions Water trickling sounds Water is picked up and distributed over the coil. This improves the efficiency and helps with water removal. Water dripping Water will collect in the base pan during high humidity days. This can cause overf

Summary of the content on the page No. 18

Configuration Settings The control can be configured to operate a wide range of options. The options listed below with the * are the factory default settings. If these are acceptable, then the unit does not require any additional configuration and is fully operable. To configure the unit, first select the configuration feature code setting and then an option code to change from the factory default setting. To enter configuration feature mode: 1. Press and continue to hold the up and down arro

Summary of the content on the page No. 19

Diagnostic Maintenance & Status Report The Diagnostic Maintenance & Status Report provides detailed information on PTAC control operation and operational status includ- ing present modes, failures, airflow restriction warnings, operating temperatures, and past failures. The lower right hand dot on the center display flashes in this mode. In some cases the green LED located in the lower left hand corner of the touchpad below the OFF key will also be lit. This Green LED “Status Light“ only illum

Summary of the content on the page No. 20

Diagnostic Codes ERROR CODE STATUS DISPLAY SUGGESTED ACTION LIGHT Freeze Protection Engaged. The room temperature No Action required. This setting will disengage when measured by the wireless remote thermostat or indoor YN FP M the room temperature rises above 43°F. ambient thermistor active sensor falls below 40°F. O Open front desk switch to allow occupant unit D Fd Front Desk switch is closed. All outputs are switched off. YN operation. E No action if a wired thermostat is being used. S


Alternative user manuals
# User manual Category Download
1 Heat Controller COMFORT-CINE REG-183A User manual Air Conditioner 3
2 Heat Controller DMC24DB-1 User manual Air Conditioner 8
3 Heat Controller DMC24CA-1 User manual Air Conditioner 0
4 Heat Controller DMH36TB-1 User manual Air Conditioner 6
5 Heat Controller DMC36TB-1 User manual Air Conditioner 0
6 Heat Controller COMFORT-CINE REG-243A User manual Air Conditioner 1
7 Heat Controller Inc.10 User manual Air Conditioner 3
8 Heat Controller Inc.7.5 User manual Air Conditioner 0
9 Heat Controller Inc.12.5 TON User manual Air Conditioner 0
10 Heat Controller Inc.13 SEER User manual Air Conditioner 2
11 Heat Controller DMC36CA-1 User manual Air Conditioner 2
12 Heat Controller Inc.A-MMC18FA-1 User manual Air Conditioner 1
13 Heat Controller Inc.8.5 User manual Air Conditioner 0
14 Heat Controller DMH24DB-1 User manual Air Conditioner 3
15 Heat Controller Inc.A-MMC36FA-1 User manual Air Conditioner 4
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21