Summary of the content on the page No. 1
HW-09CV03
HW-12CV03
No.0010503559
Summary of the content on the page No. 2
Contents Parts Name ................................................................................................ 1 Operation Guide ....................................................................................... 2-4 Maintenance ............................................................................................. 5-7 Cautions ...................................................................................................... 8 Trouble Shooting .......................
Summary of the content on the page No. 3
Parts Name panel Front Air inlet (indoor side) Air outlet (indoor side) Air inlet (outdoor side) Operation panel HW-09CV03 HW-12CV03 1
Summary of the content on the page No. 4
Operation Guide Operation panel Auto swing switch Temp. setting Mode selection Auto swing COOL OFF 6 OFF ON 3 LO HI fan fan 9 LO HI Test 1 cool cool run After unit stops, don't restart it until 3 min. have elapsed. Thermostat switch Mode selection switch 2
Summary of the content on the page No. 5
Operation Guide Auto swing switch When the switch is set to " ON ", vertical louver will swing Auto swing from side to side, delivering gentle air thus making you feel very comfortable. OFF ON When it is set to " OFF ", vertical louver will stop at position. Mode selection switch Mode switch controls the fan motor speed. Cooling speed or fan speed. OFF <1> When set to "HI fan", fan motor runs at high LO HI speed to blow out strong air. fan fan <2> When set to "LO fan", fan motor runs at low spee
Summary of the content on the page No. 6
COOL 6 3 9 Test 1 run 4
Summary of the content on the page No. 7
Maintenance NOTE: Always unplug the air conditioner before servicing or moving it. When dirt accumulates on air filter, air circulation will be blocked, which causes poor cooling. It is advisable to clean air filter every two weeks for longer operation. Removal of air filter 1. Loose the air inlet by pushing "PUSH" PUSH at both sides of air inlet. 2. Open the air inlet. 3. Remove the air filter. PUSH Air filter cleaning 1. Gently flap the dirt off the air filter. 2. Carefully wash air filt
Summary of the content on the page No. 8
Maintenance Disposal of condensate 1. The drain hole on the bottom of the air conditioner will be clogged by a rubber stopper to make the condensate in the bottom tray be spattered onto the condensation to raise efficiency of heat exchange. If the spattering sound disturbs you, you can adopt the method illustrated below. Condensate runs out from the drain hole on the back of the unit. 2. Remove the rubber stopper from the drain hole on the bottom in order to make the condensate run out. In this
Summary of the content on the page No. 9
Maintenance Avoid opening door and window Don't be exposed to cold air for unless necessary. a long time. Use curtain or blind Keep heat source away from Direct sunlight may reduce cooling air conditioner. effect, always use window curtain. Keep away from me No entrance Set temp. a little bit higher After unit stops, don't restart it until 3 min. have elapsed. before going to bed. OK! enjoy a 3-min nap 7
Summary of the content on the page No. 10
Cautions Don't hang clothes in the vicinity Temperature should be set of air inlet. This will decrease properly when there are infant, cooling effect and cause abnormal child, the aged or disabled operation. in room. Baby has gone sleep had better adjust suitable temp. Before operating mode selection switch, check if the air inlet or outlet have been blocked. For longer and trouble-free operation of the unit, pay special attention to the following: Install air-con at a place strong enough to su
Summary of the content on the page No. 11
Trouble Shooting Phenomenon Resolution Check the unit Is plug firmly inserted? Readjust power supply or Doesn't work Does fuse get burned? replace fuse. Is there power? Is thermostat switch Readjust the thermostat. wrongly adjusted? Is direct sunlight in Use curtain or blind. the room? Is mode selection switch set to "Hi fan" or "Lo fan"? Shut doors and windows. No cool air or Is door or window left poor cooling open? Are there any obstacles blocking air inlet and Remove the obstacles. outlet?
Summary of the content on the page No. 12
>700mm Installation instruction Selection of the installation position 1. Select position where the structure is firm. 2. Select position where the air inlet and outlet are smooth without obstacles. 3. Select position where the cooled air can be blown to every corner. 4. Select position where there's no direct sunlight. If the sunlight is inevitable, sun shading device is required. 5. Select position where the outdoor airflow will not influence the neighbors. 6. Select position where the dr
Summary of the content on the page No. 13
B Installation instruction The installation of air conditioner(only for reference) 1. Cut a wall hole or a window hole (see Fig.1). Iron support A A B HW-09CV03 350 530 HW-12CV03 2. Fix the iron support in a firm place with Thickness of the wall expansible screws. Fig.1 Condenser 3. Take the air conditioner and its attach- ments out from the packing carton. 4. Let the rear of the air conditioner raise slightly, the drain hole on the bottom can Rubber stopper be seen. Clog i
Summary of the content on the page No. 14
Installation instruction 8. Chink the wall and window with soft Wall sponges or rubber bits in order to refrain from outside noises coming in or cooling air going out. 9. Air conditioner being fixed,insert the power plug in the socket, open the operation panel cover, turn the temperaure setting to "Test run", turn successively the mode selection to "Hi fan" and "Hi cool", Drain hose "Lo cool" and "Lo fan", inspect the air conditioner's start and running perfor
Summary of the content on the page No. 15
L N Wiring Diagram 7363749 WIRING DIAGRAM SYNCHROMOTOR BOATSWITCH R BL R M R FAN MOTOR Y R M B FAN CAPACITOR OR OPTIONAL SWITCH 4 1 2 3 BL LO FAN LO COOL C HI COOL THERMOSTAT HI FAN L COMP. COMP. OFF B CAPACITOR S R M 0 C R BR BR PROTECTOR BL Y/G BL BL BL Y/G POWER TERMINAL TERMINAL BLOCK BLOCK R: RED OR:ORANGE B: BLACK Y:YELLOW BL: BLUE BR: BROWN NOTE: BECAUSE OF DIFFERENT COMPRESSOR, Y/G:YELLOW/GREEN THE DOTTED PART MAY NOT BE USED. HW-09CV03 2600 980 5.0 330 1.2 605X560X405 36Kg Yes HW-12C
Summary of the content on the page No. 16
With 3 years warranty on all air- conditioner compressors, you have peace of mind from the date of purchase sales office