Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB user manual

User manual for the device Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB

Device: Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB
Category: Ventilation Hood
Manufacturer: Greenheck Fan
Size: 6.89 MB
Added : 4/14/2014
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB.

For your convenience

If looking through the Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Greenheck Fan Centrifugal Roof Downblast Exhaust Fans GB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Centrifugal Roof Downblast Exhaust Fans
• General Clean Air • Light Contaminants
• Seismic • High Wind • Variable Volume
Models G and GB
Performance data now included.
June
2011

Summary of the content on the page No. 2

Models G and GB Spun Aluminum • Downblast Centrifugal Roof Exhaust Fans PERFORMANCE AND DIMENSIONS: Contents Model Comparison . . . . . . . . . . . . . . . . . . . . . 3 . Models G-060-095 . . . . . . . . . . . . . . . . . . 14-17 Models G-097-G203 . . . . . . . . . . . . . . . . . 18-31 Construction Features . . . . . . . . . . . . . . . . . 4-5 GB-071-200 . . . . . . . . . . . . . . . . . 18-32 Emergency Smoke Control . . . . . . . . . . . . . . 6 . Models GB-220-540 . . . . . . . . .

Summary of the content on the page No. 3

Models G and GB Spun Aluminum • Downblast Centrifugal Roof Exhaust Fans Model Comparison Drive Impeller Performance Location Mounting Airflow Application Type Type Model G 6,308 1 .5 $         GB 44,700 3 .25 $          *High wind limited to sizes 300 and smaller **Smoke Control available on models: 101, 101HP, 121, 131, 141, 141HP, 161, 161HP, 200, 240, 300, 360, 420 and 480 . Greenheck models G and GB centrifugal roof exhaust provide the industry’s best performance and

Summary of the content on the page No. 4

Construction Features Models G and GB Standard Construction Features An aluminum, backward-inclined, non-overloading centrifugal wheel is utilized to generate high-efficiency and minimal sound . Wheel cones are carefully matched to Wheel 1 the venturi for maximum efficiency. Each wheel is robotically welded and statically and dynamically balanced for long life and quiet operation . NEMA-1 switch is factory mounted and wiring is provided from the motor as standard Disconnect (other switche

Summary of the content on the page No. 5

Construction Features Models G and GB 6 7 5 15 1 11 14 12 8 MODEL G DIRECT DRIVE 8 DRIVE FRAME (BELT DRIVE) 3 10 4 8 16 2 9 13 18 19 MODEL GB BELT DRIVE 17 5

Summary of the content on the page No. 6

Applications G and GB models Emergency Smoke Control - GB When you buy a Greenheck • UL/cUL Listed for 500°F (260°C) for 4 hours and model GB with the smoke 1,000°F (538°C) for 15 minutes . control option, you receive a • Half the weight of traditional smoke control fans, fan with the industry’s best ideal choice for roof load concerns . performance and durability for • Low profile, height is less than half of traditional smoke control applications (as 1 smoke control fans, maximum of 5

Summary of the content on the page No. 7

Applications G and GB models High Wind and Hurricane - G and GB Greenheck is leading the High Wind Standard for roof top fans and ventilators. Forceful winds and wind-borne debris are the cause of most hurricane damage. Hurricane winds start at 75 mph. At speeds over 150 mph, wind can exert a force of 75 pounds per square foot of pressure or over 900 pounds on a fan and curb. Forceful winds are not the only problem, wind-borne debris can also cause detrimental effects to objects and struc

Summary of the content on the page No. 8

Options • Direct drive fans are often preferred where ™ Vari-Green Motor - Model G maintenance access is difficult . Greenheck’s electronically commutated • The Vari-Green motor reduces noise and vibration Vari-Green™ (VG) motor combines motor as well as providing solutions for variable volume technology, controllability and energy- system balancing . efficiency into one single low maintenance unit and Features is the industry’s first fully controllable motor . When combined with Greenhe

Summary of the content on the page No. 9

Options Example: Initial Cost Comparison Belt Drive vs. Direct Drive Vari-Green Demand Control Ventilation for multi-story buildings GB-121 Applications requiring constant pressure control or variable volume as used in G-123-VG multi-storied buildings such as hotels, multi-family complexes, institutional $0 100 200 300 400 500 600 700 facilities, and high rise commercial buildings, Fan Price VFD Price may utilize G fans with Vari-Green™ motor and The diagram show

Summary of the content on the page No. 10

Options and Accessories Roof Curbs High Wind and Severe Duty Roof Curbs Prefabricated roof curbs reduce installation time Provided as an option with models G and GB. The and costs by ensuring compatibility between severe-duty roof curb models can ship separately the fan, the curb and roof opening . All curbs are to allow for final finishing of the roof prior to the fan insulated with fiberglass. A wide variety of roof arrival and installation . curbs are available, including: flanged, pitche

Summary of the content on the page No. 11

Options and Accessories Speed Controllers for Coatings Standard Motors A wide variety of coatings and colors are available. Available for use with shaded Greenheck coatings and resistance charts can be pole and permanent split found in the Performance Coatings Commercial capacitor (PSC) open motors and Industrial Fans catalog and in our Product on model G fans . They provide Application Guide—Performance Coatings for an economical means of system Ventilation Products . balancin

Summary of the content on the page No. 12

Typical Installations Models G and GB General Clean Air (figure 1) Factory Wired from Motor to Disconnect Models G and GB exhaust fans are designed to meet the needs of general clean air applications . Tests were conducted to assure safe, rugged and reliable fans . Due to the varying types of airstreams encountered in commercial ventilation, system designers must be aware of national, state, and local codes and figure 1 guidelines governing these installations . Local code authorities sh

Summary of the content on the page No. 13

Typical Installations Models G and GB Fan Inlet Connections In order to assure proper fan performance, caution must be exercised in fan placement and connection Good to the ventilation system . Obstructions, transitions, Good poorly designed elbows, improperly selected dampers, etc ., can cause reduced performance, excessive noise, and increased mechanical stress . For performance to be as published, the system must provide uniform and stable airflow into the fan. A B Provide uniform airf

Summary of the content on the page No. 14

Roof Downblast - Exhaust Direct Drive G-060 • G-065 3 19 ⁄8 RPM (Direct) 3 Density 0.075 lb/ft (492) 3 Density 1.2 kg/m 1 *12 ⁄8 (308) 3 (76) 3 1 ⁄4 (44) 17 (432) Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) Volume (cfm) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thickness = 0.064 (1.6) Volume (m /hr ) ^Approximate Unit Weight = 15 lbs. (7 kg) Direct Drive RPM All dimensions in inches (millimeters) . *May be greater depending

Summary of the content on the page No. 15

Roof Downblast - Exhaust Direct Drive G-070 • G-075 3 RPM (Direct) 19 ⁄8 3 Density 0.075 lb/ft (492) 3 Density 1.2 kg/m 1 *12 ⁄8 (308) 3 (76) 3 1 ⁄4 (44) 17 (432) Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) Volume (cfm) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thickness = 0.064 (1.6) /hr ) Volume (m ^Approximate Unit Weight = 15 lbs. (7 kg) Direct Drive RPM All dimensions in inches (millimeters) . *May be greater depending on

Summary of the content on the page No. 16

080-D 080-G 080-VG 080-E 085-E 085-D 085-G 085-VG Roof Downblast - Exhaust Direct Drive G-080 • G-085 3 21 ⁄4 0.9 220 (552) RPM (Direct Drive) RPM (Vari Green) 200 0.8 3 Density 0.075 lb/ft 3 Density 1.2 kg/m 180 0.7 160 0.6 5 ⁄8 *14 140 (371) 0.5 120 100 0.4 4 (102) 80 0.3 3 1 ⁄4 (44) 60 17 0.2 (432) 40 0.1 20 0 0.0 0 100 200 300 400 500 600 Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) Volume (cfm) Shroud Thickness = 0.064 (1.6) 0 100 200 300 400 5

Summary of the content on the page No. 17

090-E 090-G 095-E 090-D 090-VG 095-G 095-D 095-VG Roof Downblast - Exhaust Direct Drive G-090 • G-095 3 21 ⁄4 1.0 (552) RPM RPM (Vari Green) 3 Density 0.075 lb/ft 3 Density 1.2 kg/m 200 0.8 5 ⁄8 *14 150 0.6 (371) 4 (102) 100 0.4 3 1 ⁄4 (44) 17 50 0.2 (432) 0 0.0 0 200 400 600 800 1000 1200 Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 318 x 318) ( Volume (cfm) Shroud Thickness = 0.064 (1.6) 0 500 1000 1500 2000 Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thi

Summary of the content on the page No. 18

Roof Downblast Exhaust Belt & Direct Drive GB-071 • G-097 3 24 ⁄8 RPM (Belt) (619) RPM (Direct) RPM (Vari-Green) HP 3 Density 0.075 lb/ft 3 Density 1.2 kg/m 3 ⁄4 *23 (603) 3 4 ⁄8 (111) 3 1 ⁄4 (44) 19 (483) Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 (368 x 368) Volume (cfm) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thickness = 0.064 (1.6) Volume (m /hr ) ^Approximate Unit Weight G/GB = 54/60 lbs. (24/27 kg) Direct Drive RPM All dim

Summary of the content on the page No. 19

Roof Downblast Exhaust Belt & Direct Drive GB-081 • G-098 3 24 ⁄8 RPM (Belt) (619) RPM (Direct) RPM (Vari-Green) HP 3 Density 0.075 lb/ft 3 Density 1.2 kg/m 3 ⁄4 *23 (603) 3 4 ⁄8 (111) 3 1 ⁄4 (44) 19 (483) Damper Size = 12 x 12 (305 x 305) Volume (cfm) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) 3 Volume (m/hr ) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight G/GB = 54/60 lbs. (24/27 kg) Direct Drive RPM All di

Summary of the content on the page No. 20

Roof Downblast Exhaust Belt & Direct Drive GB-091 • G-099 3 24 ⁄8 RPM (Belt) (619) RPM (Direct) RPM (Vari-Green) HP 3 Density 0.075 lb/ft 3 Density 1.2 kg/m 3 ⁄4 *23 (603) 3 4 ⁄8 (111) 3 1 ⁄4 (44) 19 (483) Damper Size = 12 x 12 (305 x 305) Volume (cfm) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) 3 Volume (m /hr ) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight G/GB = 54/61 lbs. (24/28 kg) Direct Drive RPM All di


Alternative user manuals
# User manual Category Download
1 Greenheck Fan 455924 ERV-361 User manual Ventilation Hood 4
2 Greenheck Fan 455924 ERV-581 User manual Ventilation Hood 0
3 Greenheck Fan 455924 ERV-582 User manual Ventilation Hood 0
4 Greenheck Fan 464603 User manual Ventilation Hood 0
5 Greenheck Fan 455924 ERV-521 User manual Ventilation Hood 0
6 Greenheck Fan 455924 ERV-522 User manual Ventilation Hood 2
7 Greenheck Fan 463622 User manual Ventilation Hood 0
8 Greenheck Fan 462102 User manual Ventilation Hood 0
9 Greenheck Fan 461336 User manual Ventilation Hood 0
10 Greenheck Fan 468769 User manual Ventilation Hood 0
11 Greenheck Fan 468502 User manual Ventilation Hood 0
12 Greenheck Fan 471837 User manual Ventilation Hood 0
13 Greenheck Fan 470998 User manual Ventilation Hood 0
14 Greenheck Fan AX User manual Ventilation Hood 1
15 Greenheck Fan Barometric Relief Damper SEBR-10 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0