Greenheck Fan Centrifugal Roof Exhaust Fans LBP user manual

User manual for the device Greenheck Fan Centrifugal Roof Exhaust Fans LBP

Device: Greenheck Fan Centrifugal Roof Exhaust Fans LBP
Category: Ventilation Hood
Manufacturer: Greenheck Fan
Size: 0.82 MB
Added : 4/14/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Greenheck Fan Centrifugal Roof Exhaust Fans LBP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Greenheck Fan Centrifugal Roof Exhaust Fans LBP.

For your convenience

If looking through the Greenheck Fan Centrifugal Roof Exhaust Fans LBP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Greenheck Fan Centrifugal Roof Exhaust Fans LBP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Greenheck Fan Centrifugal Roof Exhaust Fans LBP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Greenheck Fan Centrifugal Roof Exhaust Fans LBP User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Greenheck Fan Centrifugal Roof Exhaust Fans LBP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Greenheck Fan Centrifugal Roof Exhaust Fans LBP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PN 453283
®
Series L: Models LB, LBP, LD, and LDP
Low Silhouette Centrifugal Roof Exhaust Fans
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting
to assemble, install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage!
Series L Exhaust Fans
Greenheck’s Seri

Summary of the content on the page No. 2

while in storage. The manufacturer will not be Receiving responsible for damage during storage. These Upon receiving the product, check to make sure suggestions are provided solely as a convenience to all items are accounted for by referencing the bill the user. of lading to ensure all items were received. Inspect each crate for shipping damage before accepting Indoor delivery. Notify the carrier if any damage is noticed. The ideal environment for the storage of fans and The carrier wil

Summary of the content on the page No. 3

Machined parts coated with rust preventive should oil. Do not destroy the continuity of the surfaces. ® be restored to good condition promptly if signs of Thoroughly wipe clean with Tectyl 506 (Ashland Inc.) rust occur. Immediately remove the original rust or the equivalent. For hard to reach internal surfaces ® preventive coating with petroleum solvent and clean or for occasional use, consider using Tectyl 511M with lint-free cloths. Polish any remaining rust from Rust Preventive, WD-40® or

Summary of the content on the page No. 4

C l o c k Removing From Storage Pre-Starting Belt Tension Checks As fans are removed from storage to be installed 6. Always loosen tension enough to install belt in their final location, they should be protected without stretching, see Figure 3. and maintained in a similar fashion until the fan BELTS equipment goes into operation. Pre-Startup Checks 1. Check all fasteners for tightness. The wheel should rotate freely and be aligned as shown in Do not force belt(s). Forcing the Figure 1. b

Summary of the content on the page No. 5

C l o c k G CORRECT WRONG WRONGWRONG WARNING Always disconnect, lock and tag power source before servicing. Failure to disconnect power source can result in fire, shock or serious injury. WARNING Belt Span Deflection = 64 Belt Span Uneven cleaning of the wheel will produce an out of balance condition that will cause vibration in the fan. WARNING This unit should be made non-functional when cleaning the wheel or housing (fuses removed, disconnect locked off). Figure 6 Belt/Bearing Maintena

Summary of the content on the page No. 6

Parts List NOTE: Each fan bears a manufacturer’s nameplate with model number and serial number embossed. This information will assist the local Greenheck representative and the factory in providing service and replacement parts. Before taking any corrective action, make certain unit is not capable of operation during repairs. CAUTION: A fan manufactured with an explosion-resistant motor does not certify the entire unit to be explosion proof. Refer to UL Listing Mark for the fans approved usag

Summary of the content on the page No. 7

Troubleshooting WARNING: Before taking any corrective action, make certain unit is not capable of operation during repairs. PROBLEM CAUSE CORRECTIVE ACTION Check system for proper operation of backdraft or System resistance too high control dampers; remove obstructions in ductwork, etc. Unit running backwards See Pre-Starting Checks. Reduced Airflow Fan speed too low Increase fan speed. Excessive dirt buildup on Clean wheel. wheel Improper wheel alignment Center wheel on inlets. Bad Bearings R

Summary of the content on the page No. 8

Maintenance Log Date Time Notes Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be return


Alternative user manuals
# User manual Category Download
1 Greenheck Fan 455924 ERV-361 User manual Ventilation Hood 4
2 Greenheck Fan 455924 ERV-581 User manual Ventilation Hood 0
3 Greenheck Fan 455924 ERV-582 User manual Ventilation Hood 0
4 Greenheck Fan 464603 User manual Ventilation Hood 0
5 Greenheck Fan 455924 ERV-521 User manual Ventilation Hood 0
6 Greenheck Fan 455924 ERV-522 User manual Ventilation Hood 2
7 Greenheck Fan 463622 User manual Ventilation Hood 0
8 Greenheck Fan 462102 User manual Ventilation Hood 0
9 Greenheck Fan 461336 User manual Ventilation Hood 0
10 Greenheck Fan 468769 User manual Ventilation Hood 0
11 Greenheck Fan 468502 User manual Ventilation Hood 0
12 Greenheck Fan 471837 User manual Ventilation Hood 0
13 Greenheck Fan 470998 User manual Ventilation Hood 0
14 Greenheck Fan AX User manual Ventilation Hood 1
15 Greenheck Fan Barometric Relief Damper SEBR-10 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0