Franke Consumer Products FCH 906 XS ECS user manual

User manual for the device Franke Consumer Products FCH 906 XS ECS

Device: Franke Consumer Products FCH 906 XS ECS
Category: Ventilation Hood
Manufacturer: Franke Consumer Products
Size: 2.3 MB
Added : 9/30/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Franke Consumer Products FCH 906 XS ECS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Franke Consumer Products FCH 906 XS ECS.

For your convenience

If looking through the Franke Consumer Products FCH 906 XS ECS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Franke Consumer Products FCH 906 XS ECS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Franke Consumer Products FCH 906 XS ECS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Franke Consumer Products FCH 906 XS ECS User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Franke Consumer Products FCH 906 XS ECS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Franke Consumer Products FCH 906 XS ECS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



Instructions for use and installation
GB
Cooker Hood
Vejledning for installation brug og vedligeholdelse
DK
Emhætte

Handbok för installation användning och underhăll
SE
Köksfläkt

Håndbok for installasjon bruk og vedlikehold
NO
Kjøkkenvifte

Asennus-, käyttö- ja hoito-opas
FI
Liesituuletin





FCH 906 XS ECS

Summary of the content on the page No. 2

Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................7 CHARACTERISTICS..............................................................................................................................................................8 INSTALLATION ...................................................................................................................................

Summary of the content on the page No. 3

Brugsvejledning INDHOLD RÅD OG ANVISNINGER......................................................................................................................................................17 APPARATBESKRIVELSE ....................................................................................................................................................18 INSTALLATION ......................................................................................................................

Summary of the content on the page No. 4

Bruksanvisning INNEHÅLL REKOMMENDATIONER OCH TIPS....................................................................................................................................27 EGENSKAPER .....................................................................................................................................................................28 INSTALLATION ........................................................................................................................

Summary of the content on the page No. 5

Bruksanvisning INNHOLD ANBEFALINGER OG FORSLAG.........................................................................................................................................37 EGENSKAPER .....................................................................................................................................................................38 INSTALLASJON ......................................................................................................................

Summary of the content on the page No. 6

Käyttöopas SISÄLTÖ SUOSITUKSET JA EHDOTUKSET .....................................................................................................................................47 MITAT JA OSAT ...................................................................................................................................................................48 ASENNUS................................................................................................................................

Summary of the content on the page No. 7

RECOMMENDATIONS AND SUGGESTIONS INSTALLATION  The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.  The minimum safety distance between the cooker top and the extrac- tor hood is 650 mm.  Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.  For Class I appliances, check that the domestic power supply guaran- tees adequate earthing. Connect the extractor to the exhaust f

Summary of the content on the page No. 8

CHARACTERISTICS Dimensions  Components  Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower,     Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section  9 1 Reducer Flange ø 150-120 mm  10 1 Damper ø 150  14.1 2 Air Outlet Connection Extension  15 1 Air Outlet Connection  Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets  7.3 1 Air Outlet Connection Supp

Summary of the content on the page No. 9

INSTALLATION Wall drilling and bracket fixing      Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.  Draw a horizontal line at 650 mm above the hob.  Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit align- ing the centre (notch) with the vertical reference line.  Mark the wall at the centres of the hol

Summary of the content on the page No. 10

Mounting the hood body   Before attaching the hood body, tighten the two screws Vr lo- cated on the hood body mounting points.  Hook the hood body onto the screws 12a.  Fully tighten support screws 12a.   Adjust screws Vr to level the hood body. Connections DUCTED VERSION AIR EXHAUST SYSTEM      When installing the ducted version, connect the hood to the  chimney using either a flexible or rigid pipe ø 150 or 120mm, the  choice of which is left to the installer. 

Summary of the content on the page No. 11

 RECIRCULATION VERSION AIR OUTLET  Put connection 15 into the connection support 7.3.   Insert the connection extension pieces laterally 14.1 in connec- tion 15.  Make sure that the outlet of the extension pieces 14.1 is hori-  zontally and vertically aligned with the chimney outlets.  Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.  Ensure that the activated cha

Summary of the content on the page No. 12

USE       Control panel TOUCH CONTROL FUNCTION T1 ON/OFF Motor Switches the hood motor on and off. The latest selected speed appears on the display. T2 Speed - Decreases the suction speed: V3 → V2 → V1 T3 Speed + Increases the suction speed: V1 → V2 → V3 T4 Intensive speed Activates the intensive speed from any previously selected speed. The intensive speed can be activated even when the motor is OFF. By pressing the same touch control once again or by switching off

Summary of the content on the page No. 13

MAINTENANCE Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS  The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.  Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.  Wash the filters, taking care not to bend them. Allow them to dry before refitting.  When refitting the filters, make sure that the handle is visible o

Summary of the content on the page No. 14

TM EASY CLEANING Removing the Grease Filters Before carrying out Maintenance on the E- ASY CLEANING Suction Unit:  Disconnect the hood by switching off the twopole switch on the mains power supply A line, or by switching off the main power switch.  Remove the grease filters from the hood.  If the hood is of the recirculation type, re- move the odour filters:  For hoods with a flat cartridge (A): turn the fastening elements provided; B  For hoods with a bayonet cartridge (B):

Summary of the content on the page No. 15

Dismantling Washable Parts  To remove the side grilles protecting the fans, lift up the stop tooth using a knife or screwdriver and turn the grilles in the direc- tion indicated by the arrow.  Grasp the fans in the holes provided and pull to extract. CLEANING  Wash the fans and the protection grilles, using normal washing-up liquid. These e- lements can also be washed in the dish- washer.  Using a damp cloth and a suitable deter- gent, clean the body of the suc

Summary of the content on the page No. 16

REASSEMBLY N.B. To avoid reassembling the wrong way round, the two fans have different couplings.  Reassemble the fans on the corresponding pins, pressing them until they snap into place.  Fit the protection grilles so that the teeth coincide in the “FREE” position and when turned to “LOCK”.  Replace the EASY CLEANING suction unit on the hood, inserting it in position and connecting it to the support pins.  Turn the lock levers, or screw in the lock plugs.  C

Summary of the content on the page No. 17

RÅD OG ANVISNINGER INSTALLATION  Producenten kan ikke holdes ansvarlig for eventuelle skader, der skyldes ukorrekt eller forkert installation.  Den mindst tilladelige sikkerhedsafstand mellem komfurets top og emhættens underside er 650 mm.  Kontrollér, at lysnetspændingen er den samme som den spænding, der er angivet mærkepladen, der sidder på inde i emhætten.  For Klasse I apparater skal det også kontrolleres, at elforsyningen er forsynet med jord.  Emhætten kobles til aftræ

Summary of the content on the page No. 18

APPARATBESKRIVELSE Dimensioner  Komponenter  Ref. Stk. Produktets komponenter 1 1 Emhættens hoveddel inkl.: Betjeningsanordninger, lys,     ventilatorenhed, filtre 2 1 Teleskopaftræk bestående af: 2.1 1 Øverste aftræk 2.2 1 Nederste aftræk  9 1 Passtykke ø 150-120 mm 10 1 Sidestykke med ventil   14.1 2 Forlænger til luftudstrømnings overgangsstykke  15 1 Luftudstrømnings overgangsstykke  Ref. Stk. Installationsdele 7.2.1 2 Beslag til befæstigel

Summary of the content on the page No. 19

INSTALLATION Boring i væg og befæstigelse af beslag      På væggen skal der afmærkes:  en lodret linje op til loftet eller den øverste grænse, i midten af emhættens monteringsområ- de;  en vandret linje mindst 650 mm over kogepladen.  Placér beslaget 7.2.1 som vist, d.v.s. 1-2 mm fra loftet eller den øverste grænse, og stil dets midte (indskæringer) på lige linje med den lodrette referencelinje.  Afmærk midten af hullerne i beslaget.  Placér beslaget 7.2

Summary of the content on the page No. 20

Montering af emhætte   Inden man hænger emhætten op, skal man stramme de to skruer Vr, som sidder i hættens ophængningspunkter.  Hæng emhætten op på de forberedte skruer 12a.  Stram ophængningsskruerne 12a helt til.   Ved at dreje på skruerne Vr nivelleres emhætten. Tilslutninger VERSION FORBUNDET TIL AFTRÆKSKANAL      Når aftrækskanal-versionen opsættes, forbindes emhætteenheden  til kanalen med en flexslange eller et hårdt rør, Ø150 eller 120  mm – valget er o


Alternative user manuals
# User manual Category Download
1 Franke Consumer Products FDC 602 User manual Ventilation Hood 2
2 Franke Consumer Products FDL 304 W User manual Ventilation Hood 0
3 Franke Consumer Products FDF 9046 User manual Ventilation Hood 18
4 Franke Consumer Products FDL 654 User manual Ventilation Hood 8
5 Franke Consumer Products FDF 6046 User manual Ventilation Hood 3
6 Franke Consumer Products FDL 364 W User manual Ventilation Hood 0
7 Franke Consumer Products FDF 364 W User manual Ventilation Hood 1
8 Franke Consumer Products FDS 307 W User manual Ventilation Hood 1
9 Franke Consumer Products FDS 367 W User manual Ventilation Hood 1
10 Franke Consumer Products FGA 364 W User manual Ventilation Hood 0
11 Franke Consumer Products FDL 954 User manual Ventilation Hood 3
12 Franke Consumer Products FGL 6015 XS User manual Ventilation Hood 1
13 Franke Consumer Products FGL 7015 XS User manual Ventilation Hood 7
14 Franke Consumer Products FGL 6104 XS ECS User manual Ventilation Hood 0
15 Franke Consumer Products FGL 9104 XS ECS User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0