Summary of the content on the page No. 1
Installation Manual
RANGE HOOD
MODEL:BUF-01
BUF-02
TABLE OF CONTENTS
Safety Instructions .................................................................................................. 2
Name of Parts ......................................................................................................... 4
Size & Dimensions .................................................................................................. 4
Range Hood Location .................................................
Summary of the content on the page No. 2
SAFETY INSTRUCTIONS ○○○○○○○○○○○○ ○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○ Before installation and operation, read these instructions carefully and use this product only in the manner described by the manufacturer in the operation manual. The signal words shown below are used to alert you to potential personal injury and property damage hazards. There are three hazard classifications based on potentially dangerous situations. Obey all safety instructions that show these symbols to avoid p
Summary of the content on the page No. 3
CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors. 2. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings or into attics, crawl spaces or garages. 3. Read specification label on this product for further information and requirements. 4. Use only for the purpose of kitchen ventilation. 5. Do not install this range hood in the bathroom or in other
Summary of the content on the page No. 4
NAME OF PARTS - Accessories - - Accessories - - Accessories - - Accessories - - Accessories - Screw M5×30 Nut with plate Four (4) pieces Four (4) pieces SIZE & DIMENSIONS (Unit : inch) 4
Summary of the content on the page No. 5
RANGE HOOD LOCATION The range hood must be installed just above the cooktop. 1 The minimum distance from the cooking surface to the bottom of the range hood must be 24". 2 The total weight of the BUF-01/BUF-02 range hood unit is: 3 BUF-01/BUF-02 ----- 18 lbs. (8 kg) Power requirements are: 4 BUF-01 AC120 V, 60 Hz, 1.3 Amp BUF-02 AC120 V, 60 Hz, 2 Amp CAUTION Check that the hood is correctly installed, since incorrect installation could result in the detachment of the range hood and the unit fa
Summary of the content on the page No. 6
INSTALLATION 1. PREPARATION WARNING • If the range hood is not installed properly, it could become detached and fall. Ensure that the metal duct does not touch other metal housing materials, otherwise fire or electric shock could result. This range hood is designed to discharge upward. For vertical discharge, 1 run duct work between the hood location and roof cap location. To get the best result, use a minimum number of transitions and elbows. Be sure to attach a roof cap to avoid leaking rain
Summary of the content on the page No. 7
INSTALLATION (continued) Run house wiring between service panel and hood location. 3 Prepare the range hood unit. 4 (1) The range hood is supplied with the exhaust pipe fixed on its top plate. (2) Provide a transition duct (not supplied) to connect the exhaust pipe and external duct. The diameter of the transition duct should be more than 6". (3) Be sure to keep 1-3/16" overlapping length of the exhaust pipe and transition duct. 7
Summary of the content on the page No. 8
INSTALLATION (continued) 2. RANGE HOOD MOUNTING Hold up the range hood unit and insert it into the opening of the liner. When the 4 securing plates on both sides have passed through the top of the liner, turn them 1 outward to secure the range hood on the liner temporarily. Make sure that the top of the exhaust pipe is inserted into the bottom of the transition duct. 8
Summary of the content on the page No. 9
INSTALLATION (continued) Remove 4 screws which are fixed to the front cover. The front cover swings open 90° as shown in Fig. 2 CAUTION Do not detach the front cover from the range hood unit. The hinge may be damaged. Align 4 screw holes of the liner and range hood unit, then fix securely using the supplied screws and nuts. 3 NOTE Fasten all screws and nuts evenly. Make the duct joint secure and air tight using non-flammable tape such as duct 4 tape, etc. (not supplied) NOTE Make sure that the s
Summary of the content on the page No. 10
INSTALLATION (continued) 3. CONNECTING POWER SUPPLY WIRES WARNING Electrical wiring should be done by a qualified person(s) in accordance with all- applicable codes and standards, including fire-rated construction. An unqualified person doing the work could result in fire, electric shock or injury. This range hood uses 120V AC. Do not connect to other voltage since fire, electric shock or damage could result. Remove the nut from the conduit connector at the end of power wiring. 1 WARNING Be
Summary of the content on the page No. 11
INSTALLATION (continued) Connect the electrical wires as follows: Connect wires tightly and securely using wire connectors (not supplied). 4 Black to Black White to White Green to Green Replace the wire cover with the screw removed previously. Make sure that all wires are connected properly and enclosed inside of the wiring compartment. 5 11
Summary of the content on the page No. 12
INSTALLATION (continued) 4. FINAL ASSEMBLY AND CHECK One 40 W light bulb (not supplied) can be mounted to this range hood. Prior to final assembly, install a light bulb (ordinary type, in the base diameter 17 mm: intermediate base), rated 120 V-40 W or below. Assembly Replace the front cover with 4 screws. 1 CAUTION To prevent the screw holes from being damaged, be sure to tighten the screws with the torque of 13 inch-lbs. (1.5 N-m) or less. Check (1) Turn on the electrical circuit to the range
Summary of the content on the page No. 13
INSTALLATION (continued) 5. EXPLANATION TO THE END USER (1) Refer to the Operation Manual, explain the operation of this range hood to end users. (2) The Installation Manual and Operation Manual should be given to the end user. CIRCUIT DIAGRAM 120V 60Hz Motor Green Connector Terminal Black White Capacitor Red White Orange Red Brown Blue Bulb:Max40W Connector Blue Brown Orange White Black Red Green Control Switch 13 Blue Brown Orange White Black Green
Summary of the content on the page No. 14
Fuji Industrial USA, Inc. 16300 Christensen Rd., Ste-212 Seattle, WA 98188-3403 Telephone: 1-888-547-9880 1U030584