DeLonghi EUROCHEF - PRO user manual

User manual for the device DeLonghi EUROCHEF - PRO

Device: DeLonghi EUROCHEF - PRO
Category: Ventilation Hood
Manufacturer: DeLonghi
Size: 6.14 MB
Added : 1/30/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for DeLonghi EUROCHEF - PRO. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with DeLonghi EUROCHEF - PRO.

For your convenience

If looking through the DeLonghi EUROCHEF - PRO user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual DeLonghi EUROCHEF - PRO on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual DeLonghi EUROCHEF - PRO to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
DeLonghi EUROCHEF - PRO User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual DeLonghi EUROCHEF - PRO but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to DeLonghi EUROCHEF - PRO. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EUROCHEF - PRO WALL HOOD
EUROCHEF - PRO WALL HOOD
INSTALLATION INSTRUCTIONS
2 3 TIMER
1
Shown with accessory Duct Cover Kit and accessory Warming Lamp Kit
APPROVED FOR ALL RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Leave these Instructions with this unit for the owner.
OWNER: Retain these instructions for f

Summary of the content on the page No. 2

EUROCHEF - PRO WALL HOOD HOODS WEIGHT MODEL NUMBER FEATURES Controls: 4-speed electronic with 15” minute delayed shutoff 24” range hood with 600 CFM blower 22 lbs EC PH24S timer 30” range hood with 600 CFM blower 30 lbs EC PH30S Fabrication: Welded, polished and brushed seams 36” range hood with 600 CFM blower 36 lbs EC PH36S All edges hemmed Features: 304 stainless hood baffle filter and grease tray 48” range hood with 1200 CFM blower 48 lbs EC PH48S 12V halogen lighting, lamps included Top and

Summary of the content on the page No. 3

EUROCHEF - PRO WALL HOOD READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY CONSIDERATIONS BEFORE WARNING INSTALLING HOOD TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. For the most efficient air flow exhaust, use a straight run or as few A. Use this unit only in the manner intended by the manufac- elbows as possible. turer. If you have any questions, contact the manufacturer. 2. Do not use flex ducting use metal ductwork only to reduce the risk B. Be

Summary of the content on the page No. 4

EUROCHEF - PRO WALL HOOD PRODUCT DIMENSIONS CONTENTS AND PAGE NUMBER Product Dimensions....................................................... pg.4 Advance Planning...........................................................pg.5 Using Duct Cover Accessories........................................ pg.5 Tools and Materials Required ......................................... pg.5 Remove the packaging................................................... pg.6 Parts Provided...............................

Summary of the content on the page No. 5

EUROCHEF - PRO WALL HOOD ADVANCE PLANNING 36” (914 mm) Cabinetry and electrical placement for 24-inch deep wall hoods. lnstallatian dimensions for 24 deep wall hoods. USING DUCT COVER ACCESSORIES To avoid gaps, plan the hood installation height for duct cover use. Recirculating Kit Cover 4” (if used) Duct cover 6” Duct cover 12” 1. Duct covers and Recirculating Kit covers are stackable. 2. The hood is 18” tall and can be installed from 24” to 36” above cooking surface (30” to 36” is optimum). 3

Summary of the content on the page No. 6

EUROCHEF - PRO WALL HOOD Parts Included with your Hood REMOVE THE RANGEHOOD • Hood with blower installed DO NOT GRAB BODY HERE • 12-Volt halogen bulbs, installed • Care & Use /Installation Instructions • Registration Card GRAB BODY HERE • Filters (24” & 30” = 2; 36” = 3; 48” = 4) • Grease trap (24” & 30” = 2; 36” = 3; 48” = 4) • Transition with Back draft damper GRAB BODY • Fasteners HERE • Wooden bracket for Hood Support Parts Not Included with your Hood • Duct Cover Kit, 6" or 12" height

Summary of the content on the page No. 7

EUROCHEF - PRO WALL HOOD REMOVE FILTER FRAME STEP 1 DETERMINE HOOD, DUCTWORK - Remove Filter Frame per photographs AND WIRING LOCATIONS - Store Filter Frame in safe place so it will not be damaged. - Do not loose the Filter Frame screws, re-screw them loosely, • Use a level to draw the cooktop centerline vertically up the back into the hood. wall to the ceiling. • Measure desired distance from the bottom of the hood to OTHER PREPARATIONS the cooking surface, 24" min. to 36" max. • Move blower to

Summary of the content on the page No. 8

EUROCHEF - PRO WALL HOOD BLOWER POSITION CHART Hood size Motor Recirculating Kit option Top ducting option Rear ducting option 24” 1 YES YES YES 30” 1 YES YES YES 30” 2* NO YES NO 36” 1 YES YES YES 36” 2* NO YES NO 48” 2 NO YES NO (*) with Blower Upgrade Kit BLOWER POSITION OPTION model 24 model 30 36 model 30 36 Vertical Discharge Vertical Discharge model 48 two blowers Vertical Discharge (with Blower Upgrade Kit) model 24 model 30 36 model 30 36 Horizontal Discharge Horizontal Discharge m

Summary of the content on the page No. 9

EUROCHEF - PRO WALL HOOD IF CHANGING BLOWER POSITION SECURITY SCREW 1. Disconnect motor from power supply 2. Remove Blower security screw from blower bracket and remove blower. 3. Loosen 4 screws from blower bracket. 4. Shift blower to right and Remove Blower. 5. Loosen 4 screws and remove sealing plate covering back venting hole. 6. Reverse this procedure in new locations. 7. Reconnect blower to power supply. BLOWER UPGRADE KIT 30” AND 36” HOODS A “A”: remove bracket knock out nd before fixing

Summary of the content on the page No. 10

1 2 3 TIMER TIMER EUROCHEF - PRO WALL HOOD STEP 3A: INSTALL HOOD ONTO WALL (see enclosed template) SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET, GO TO STEP 3B. • Affix enclosed paper template to wall. • Insert hood mounting screws in the Wood Bracket at the • From the line indicating the bottom of the hood, measure locations shown in the diagram, so screws protrudes 1/4". 17” up and draw another line for the location of the Wood This 1/4” gap will provide clearance to hang the hood

Summary of the content on the page No. 11

EUROCHEF - PRO WALL HOOD • Affix enclosed paper template to wall STEP 3B: ALTERNATE MOUNTING METHOD IMPORTANT: FRAMING MUST BE CAPABLE OF INSTALL HOOD TO SOFFIT OR BENEATH CABINETS SUPPORTING UP TO 150 LBS SKIP THIS STEP IF USING WALL MOUNTING METHOD Mount Hood onto Soffit or Cabinet When necessary, the hood may be installed so that it is supported by the soffit. Note: If mounting to the underside of a cabinet with a recessed • The soffit should be constructed with 2 x 4’s. bottom, install shims

Summary of the content on the page No. 12

EUROCHEF - PRO WALL HOOD • Use wire nuts to connect incoming ground, neutral and hot. STEP 4: CONNECT DUCTWORK • Push wires into junction box and replace cover. Be sure wires are not pinched. • Install ductwork. • Secure joints in ductwork and transition with sheetmetal screws and duct tape for an airtight seal. STEP 6: INSTALL DUCT COVERS • ATTENTION: Be sure that screws do not hamper the dampers movement. STEP 5: CONNECT ELECTRICAL Verify that power is turned off at the source. WARN

Summary of the content on the page No. 13

EUROCHEF - PRO WALL HOOD STEP 7: TIGHTEN - HANGING SCREWS • With Filter Frame still removed from Step 2 • Adjust hood up to eliminate any gaps at ceiling. Tighten hanging screws. • Add (2) more security screws + Washers at wood bracket. • IMPORTANT: If Installing optional Backsplash Kit install this kit BEFORE installing wall anchors (see instruction with kit) Install Bottom Wall Anchors • Drill 1//8" pilot holes into the two lower mounting holes. Enlarge the holes if they did not enter stud

Summary of the content on the page No. 14

EUROCHEF - PRO WALL HOOD STEP 9: INSTALL FILTER STEP 10: TEST FUNCTION OF HOOD - Blower - Light • Place filter drip trays into the bottom rear of the hood. • Insert top of grease filter first, than rotate bottom filter and drop into grease tray. • To remove the filters, grasp the handle, push the filter up and lift out. Air-2 14

Summary of the content on the page No. 15

EUROCHEF - PRO WALL HOOD CARE AND USE OPERATION Press any speed to turn hood on. Press same button to turn REPLACING HALOGEN BULB hood off. Active speed is shown by a button back light. ROTATE CONTROL: 1. 1 Speed 2. 2 Speed 3. 3 Speed 4. 4 Speed Light DELAYED SHUTOFF By pressing down on any speed key for 2 seconds, while hood is running the 15 minute Delayed Shutoff mode will start indicated by flashing backlight. After 15 minutes the hood will shutoff. WARRANTY: Eurochef USA warrants the USA

Summary of the content on the page No. 16

EUROCHEF - PRO WALL HOOD EUROCHEF U.S.A. 41 MERCEDES WAY SUITE 25 EDGEWOOD NEW YORK 11717 – TEL. 866-844-6566 WWW.DELONGHIMAJORAPPLIANCES.COM WWW .DELONGHI RANGES.COM Air-2 16


Alternative user manuals
# User manual Category Download
1 DeLonghi DFH550R User manual Ventilation Hood 18
2 Sony SH-L35W User manual Ventilation Hood 0
3 Air King AIF8X User manual Ventilation Hood 3
4 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
5 Air King AIF10X User manual Ventilation Hood 0
6 Agilent Technologies 31A User manual Ventilation Hood 0
7 Air King 500CFM User manual Ventilation Hood 0
8 Agilent Technologies 6610XA User manual Ventilation Hood 1
9 Air King AIK14X User manual Ventilation Hood 0
10 Agilent Technologies HP 83621A User manual Ventilation Hood 0
11 Air King 380 CFM User manual Ventilation Hood 38
12 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2
13 Air King AD series User manual Ventilation Hood 1
14 AEG DD 8665 User manual Ventilation Hood 4
15 AEG 230 D User manual Ventilation Hood 1