CDA EVM9 user manual

User manual for the device CDA EVM9

Device: CDA EVM9
Category: Ventilation Hood
Manufacturer: CDA
Size: 1.21 MB
Added : 6/28/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for CDA EVM9. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with CDA EVM9.

For your convenience

If looking through the CDA EVM9 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual CDA EVM9 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual CDA EVM9 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
CDA EVM9 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual CDA EVM9 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to CDA EVM9. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EVM9 Extractors
Manual for Installation, Use and Maintenance
Passionate about style
Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY
T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu

Summary of the content on the page No. 2

Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that the manufacturer reserves the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment. This appliance is not designed to be used by people (including children) with reduced physical, sensorial or mental capacity, or who lack experience or knowle

Summary of the content on the page No. 3

Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Control Panel A - Light key B - Decrease speed key C - Display D - Increase speed key E - Timer key Fig. 1 B A C D E To switch the extractor light on and off • Touch key A. To switch on the extractor • Touch either key B or D. The appliance will switch on at the first speed. • To increase the speed

Summary of the content on the page No. 4

Care and Maintenance IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. 2 Cleaning You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean your extractor effectively by simply using a dilute solution of water 2 and mild detergent and drying to a shine with a clean cloth. 1 Cleaning the grease filter The grease filter sh

Summary of the content on the page No. 5

Changing the Light IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Carefully prise the bulb from the extractor using a small, flat-bladed screwdriver. Refit the new bulb taking care not to touch the glass (Fingerprints will lead to premature failure of the bulb). Fig. 5 Do not touch bulbs or adjacent areas

Summary of the content on the page No. 6

Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations. DOUBLE POLE SWITCHED The wires in the mains lead of this appliance are coloured in accordance with the FUSED SPUR OUTLET following

Summary of the content on the page No. 7

Installation Your extractor can be used to filter and recycle the air within your kitchen, or to extract the air outside. When extracting air to the outside, the unit can be vented as shown in the diagram below. Note that we recommend the use of ducting with a diameter of 150mm. Ducting with diameters of 100mm or 120mm may be used, but performance will be reduced. When installing this appliance over a CDA hob, the clearance between the extractor and the hob must be equal to or exceed 450m

Summary of the content on the page No. 8

Fitting your extractor to the wall Next, remove the top cover by loosening the screws (b), closing the front panel and then lifting the cover off. The extractor is mounted using four screws. Ensure that the wall fixings and screws are suitable for the wall material. Mark the positions of the four holes on the wall, according to (fig 11.) Fig. 9 Fig. 10 460 178 112.5 + 450mm for CDA Hob Fig. 11 7

Summary of the content on the page No. 9

Fitting your extractor to the wall Insert the 4 wall plugs in to the holes and fix 2 screws in the top holes so that they are protruding from the wall by approx 5mm (fig 12). Next, lift the hood onto the 2 screws as shown in (fig12). Secure the top two screws and fix the hood into position using screws inserted into the 2 lower holes (fig 13). The extractor is now secured to the wall. Fig. 12 Fig. 13 Using the extractor as a recirculation device Refit the top cover and grill as below before

Summary of the content on the page No. 10

Using the extractor as an extraction device Work out the required height of the optional chimney for your ceiling and mount the chimney fixing bracket as shown in the (fig 16), then secure the chimney as shown in (fig 17a). Finally, locate the chimney to the body of the extractor as shown in (fig 18). Fig. 16 Fig. 17 Fig. 18 9 20

Summary of the content on the page No. 11

10

Summary of the content on the page No. 12

To contact our Customer Care Department, or for Service, please contact us on the details below. Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu


Alternative user manuals
# User manual Category Download
1 CDA 3L9 User manual Ventilation Hood 0
2 CDA CYLINDER EXTRACTORS EVCK4 User manual Ventilation Hood 2
3 CDA 3D9BL User manual Ventilation Hood 0
4 CDA CPXI9 User manual Ventilation Hood 0
5 CDA 3Q9 User manual Ventilation Hood 0
6 CDA CCA5/7 User manual Ventilation Hood 0
7 CDA EVPK9 User manual Ventilation Hood 0
8 CDA CIN6 User manual Ventilation Hood 0
9 CDA EXTRACTORS CIGE9 User manual Ventilation Hood 2
10 CDA EDD9BL User manual Ventilation Hood 2
11 Sony SH-L35W User manual Ventilation Hood 0
12 Air King AIF8X User manual Ventilation Hood 3
13 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
14 Air King AIF10X User manual Ventilation Hood 0
15 Agilent Technologies 31A User manual Ventilation Hood 0