Broan GSFH1K user manual

User manual for the device Broan GSFH1K

Device: Broan GSFH1K
Category: Ventilation Hood
Manufacturer: Broan
Size: 1.14 MB
Added : 9/26/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Broan GSFH1K. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Broan GSFH1K.

For your convenience

If looking through the Broan GSFH1K user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Broan GSFH1K on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Broan GSFH1K to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Broan GSFH1K User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Broan GSFH1K but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Broan GSFH1K. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER MANUAL
HEPA Filtration and
Fresh Air
Ventilation*
GSVH1K
HEPA Filtration,
HEPA
Fresh Air and
Filtration*
Heat Recovery
GSFH1K
Ventilation*
VB0061
HEPA Filtration, GSHH3K
*Patents pending
Fresh Air and
Energy Recovery
Ventilation*
GSEH3K
RESIDENTIAL USE ONLY.
INSTALLER: LEAVE THIS MANUAL WITH CONSUMER.
REGISTER YOUR PRODUCT ON LINE AT:
www.broan.com/register
For additional information - visit www.Broan.com
05690 rev. 5
Broan-NuTone LLC 99043224

Summary of the content on the page No. 2

ABOUT THIS MANUAL Congratulations! Your purchase of this whole-house HEPA filtration, with optional ventilation will allow you and your family to enjoy clean and healthy air throughout your home for years to come! Please read this booklet thoroughly. Several models are described in this publication. Some details of your unit may be slightly different than the ones shown, as the illustrations are typical ones. This manual uses the following symbols to emphasize particular information: ! WARNING

Summary of the content on the page No. 3

TABLE OF CONTENTS 1.0 ABOUT THESE UNITS .................................................4 2.0 CONTROLS............................................................5-8 2.1 Main Switch.....................................................................5 2.2 Operating ACCGSC1 Controller .....................................5 2.3 Operating 40425 Controller .........................................6-8 3.0 MAINTENANCE.....................................................9-12 3.1 Semi-annual Maintenanc

Summary of the content on the page No. 4

1. ABOUT THESE UNITS ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING: 1. This unit is intented for residential installation only. 2. Installation must be done in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances. 4. Do not install in a cooking area or connect directly to an appliance. 5. B

Summary of the content on the page No. 5

2. CONTROLS 2.1 MAIN SWITCH All units are equipped with a 3-position main switch, located on the front panel. The unit is intented for use with a wall controller (provided, see below). The main switch is to remain in either the “OFF” or “Normal/Remote” modes ONLY. The “Normal/Remote” mode allows the homeowner to operate the product from the wall controller (supplied with the unit), typically mounted near a thermostat or other convenient location. NORMAL/REMOTE: UNITISOPERATINGON LOW SPEED. THIS

Summary of the content on the page No. 6

2. CONTROLS (CONT’D) 2.3 OPERATING 40425 CONTROLLER The included wall control 40425 is intented for GSHH3K and GSEH3K units only. The wall control is in OFF mode when power is applied for the first time. The mode does not change following a power failure. 2.3.1 40425 CONTROLLER DESCRIPTION FILTER AND PREFILTER ILLUMINATES IN MAINTENANCE LED. ALL MODES FLASHES WHEN IT IS EXCEPT OFF 40425 TIME TO REPLACE MODE. PREFILTER AND WASH CORE FILTERS. SEE SEMI-ANNUAL �PRESS EITHER MAINTENANCE IN BUTTON TO

Summary of the content on the page No. 7

2. CONTROLS (CONT’D) 2.3.2 USING 40425 CONTROLLER (CONT’D) RECIRCULATION MODE (RE-CIRC)OFF MODE The unit recirculates air. However, The unit is off. every hour, the unit exchanges The outdoor temperature* air for 6 minutes so that is not displayed. it can obtain a reading of the outdoor temperature*. AUTOMATIC MODE (AUTO) Off in Air recirculation Air exchange in Auto mode in Auto mode Auto mode The unit operates on a 60-minute cycle. For the first 40 minutes, the unit recirculates air or is of

Summary of the content on the page No. 8

2. CONTROLS (CONT’D) 2.3.3 40425 WALL CONTROLLER CONFIGURATION See the configuration table below for the list of configuration parameters. Press the Menu button for 3 seconds to enter or exit the configuration menu. NOTE: The wall control automatically saves any changes and exits the configuration menu if no button is pressed within the next 60 seconds. Press the Menu button briefly to advance to the next parameter (menu number). Press the or button to change the parameter setting. CO

Summary of the content on the page No. 9

3. MAINTENANCE ! WARNING Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source. 3.1 SEMI-ANNUAL MAINTENANCE (ESSENTIAL) Your wall controller (ACCGSC1 or 40425) tells you when to perform this maintenance when the Filter Maintenance light is flashing. Otherwise, maintenance should be performed every 6 months to ensure your unit proper operation for years to come. Follow these steps: 1. Turn switch knob to OFF to unlock the door.

Summary of the content on the page No. 10

3. MAINTENANCE (CONT’D) 3.1 SEMI-ANNUAL MAINTENANCE (ESSENTIAL) (CONT’D) 4. Using your thumbs, push on the prefilter side to disengage it from the filter cartridge. Then, slide it out of the filter cartridge and discard it. Install the new prefilter by reversing this operation. 1 2 VD0092 VD0093 1) Filter cartridge 2) Prefilter 5. Clean the inside walls of the unit with a clean damp cloth, then wipe with a dry one. Install the new filter cartridge. 6.1 For HEPA Filtration and Fresh Air Ventilati

Summary of the content on the page No. 11

3. MAINTENANCE (CONT’D) 3.1 SEMI-ANNUAL MAINTENANCE (ESSENTIAL) (CONT’D) 6.3 For HEPA Filtration, Fresh Air and Energy Recovery model GSEH3K only CAUTION The GSEH3K energy recovery core cannot be washed with water. Slide out the two core filters (item 1) from the 1 1 energy recovery core and wash them under hot water with mild soap. Remove the dust on the energy recovery core (item 2) using a vacuum cleaner with a soft brush attachment. Rinse the core filters thoroughly and let dry before 2 rei

Summary of the content on the page No. 12

3. MAINTENANCE (CONT’D) 3.3 OPTIONAL ALPINE/PINE FILTER During pollen season, or as needed, remove the assembled hood from its backplate by removing its 2 retaining screws. VD0124 screw Then, slide out the optional Alpine/pine filter and clean it under water. Let dry before reinstalling it on the assembled hood. Reinstall the hood on its backplate. VA0024 - 12-

Summary of the content on the page No. 13

4. TROUBLESHOOTING ! WARNING Shock hazard. Never open the electronic box. No user-serviceable parts inside. There is a fuse on the electronic board. Never attempt to replace it. Refer servicing to qualified service personnel. If the unit seems not working properly, call your installer or the nearest approved Service Center. You can also reach our Customer Service Departments or Technical Support listed below. Broan-NuTone LLC � Customer Service Department: Telephone: 1-800-558-1711 Fax: 1-800-35

Summary of the content on the page No. 14

5. WARRANTY WHOLE-HOUSE AIR FILTRATION SYSTEM WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products, that such products will be free from defects for a period of two (2) years, from date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BROAN-NUTONE WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A BROAN-NUTON


Alternative user manuals
# User manual Category Download
1 Broan 356BR User manual Ventilation Hood 5
2 Broan 355BR User manual Ventilation Hood 0
3 Broan 350BR User manual Ventilation Hood 2
4 Broan 46000 User manual Ventilation Hood 1
5 Broan 350BK User manual Ventilation Hood 0
6 Broan 4-Way Convertible Range Hood QL1 Series User manual Ventilation Hood 9
7 Broan 356BK User manual Ventilation Hood 0
8 Broan 355BK User manual Ventilation Hood 1
9 Broan 61000EX User manual Ventilation Hood 0
10 Broan 684 User manual Ventilation Hood 0
11 Broan 63000EX User manual Ventilation Hood 1
12 Broan ALLURE QS3 User manual Ventilation Hood 3
13 Broan 778WH User manual Ventilation Hood 0
14 Broan 758 User manual Ventilation Hood 0
15 Broan 629004 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0